Using the EM 100 G4
64
Easy Setup menu item
You can scan for unused frequencies using the
Easy Setup
menu item.
When you have connected multiple EM 100 G4 devices to a network via the
RJ-10 interfaces (see “Creating a data network”), you can perform the fre-
quency setup for all of the connected receivers. You can find more informa-
tion about connecting multiple devices under “Performing multi-channel
frequency setup”
Switch off all transmitters before you perform the scan. If transmit-
ters are still switched on, they are detected as unavailable frequen-
cies and the frequencies that are actually available cannot then be
used.
The squelch threshold setting influences the result. Set the squelch thresh-
old to
Low
for as many frequencies as possible, and to
High
for as many
safe frequencies as possible (see “Squelch menu item”).
To open the
Easy Setup
menu item:
▷
On the home screen, press the
SET
button to open the operating menu.
▷
Press the
UP
or
DOWN
button until the
Easy Setup
menu item appears
in the selection frame.
▷
Press the
SET
button to open the menu item.
Scan New List
▷
Select
Scan New List
to scan for unused frequencies.
▷
Press the
SET
button to start the scan.
The frequency range of the receiver is scanned. As a result, the number
of unused frequencies is displayed for every frequency bank.
▷
Press the
UP
or
DOWN
buttons to select a frequency bank.
▷
Press the
SET
button to confirm your selection.
▷
Press the
UP
or
DOWN
buttons to select an unused frequency from the
selected bank.
Summary of Contents for EM 100 G4