background image

+

_

Vicon

Data

Out

Power

Pwr

Pwr

Connect power to the Pwr
inputs. Do not connect
power wires to the Gnd.

n.c.

The removable mounting
clip can be snapped onto a
din rail or screwed to a
panel or wall.

SCT-CRX-Pelco-Vicon

Pelco Coaxitron to Vicon RS-422 Code Translator

Size:

4.5" x 3.5" x 1.25"

Weight:

0.5 lb

Power:

9Volt to 15Volt AC or DC at 75ma

Environmental: Indoor use only

Sennetech, Inc.  6455 W. Bath Rd.  Perry, MI  48872   U.S.A.    Ph (517) 675 1150    Fax (517) 675 1151

The Code Translator detects Pelco coaxitron control code and converts it to equivalent Vicon RS-422
control code for a single Vicon camera.

Vicon

Address Switches

The range is 0~255

An invalid setting will
cause the Err indica-
tor to light up solidly.

Tx

Indicator

Flashs when
Vicon camera
control com-
mands are
sent.

Configuration Switches

Switch1: Vicon BAud

Up:

9600 Baud

Down:

4800 Baud

Switch3: Unassigned

Up:
Down:

Switch3: Unassigned

Up:
Down:

Switch4: Unassigned

Up:
Down:

Switch 5: Unassigned

Up:
Down:

Switch6:  Output Test Pattern

Up:

Test On

Down:

Test Off

Removable edge connector.
Insert a small screwdriver in
the upper slot to force open the
wire clamp. Push all the way in
to open fully. Place stripped
wire end(s) in the open clamp
and withdraw screwdriver.

Error

Indicator

Lights solidly
for any invalid
a d d r e s s
switch set-
ting.

Video

Indicator

Illuminates
when video
sync signal
is detected.

SPECIFICATIONS

Rx

Indicator

Flashs when
coaxitron con-
trol code is
detected.

High impedance looping
coaxial video connectors.

www.sennetech.net