_
Vicon
Data
Out
Power
Pwr
Pwr
Connect power to the Pwr
inputs. Do not connect
power wires to the Gnd.
n.c.
The removable mounting
clip can be snapped onto a
din rail or screwed to a
panel or wall.
SCT-CRX-Pelco-Vicon
Pelco Coaxitron to Vicon RS-422 Code Translator
Size:
4.5" x 3.5" x 1.25"
Weight:
0.5 lb
Power:
9Volt to 15Volt AC or DC at 75ma
Environmental: Indoor use only
Sennetech, Inc. 6455 W. Bath Rd. Perry, MI 48872 U.S.A. Ph (517) 675 1150 Fax (517) 675 1151
The Code Translator detects Pelco coaxitron control code and converts it to equivalent Vicon RS-422
control code for a single Vicon camera.
Vicon
Address Switches
The range is 0~255
An invalid setting will
cause the Err indica-
tor to light up solidly.
Tx
Indicator
Flashs when
Vicon camera
control com-
mands are
sent.
Configuration Switches
Switch1: Vicon BAud
Up:
9600 Baud
Down:
4800 Baud
Switch3: Unassigned
Up:
Down:
Switch3: Unassigned
Up:
Down:
Switch4: Unassigned
Up:
Down:
Switch 5: Unassigned
Up:
Down:
Switch6: Output Test Pattern
Up:
Test On
Down:
Test Off
Removable edge connector.
Insert a small screwdriver in
the upper slot to force open the
wire clamp. Push all the way in
to open fully. Place stripped
wire end(s) in the open clamp
and withdraw screwdriver.
Error
Indicator
Lights solidly
for any invalid
a d d r e s s
switch set-
ting.
Video
Indicator
Illuminates
when video
sync signal
is detected.
SPECIFICATIONS
Rx
Indicator
Flashs when
coaxitron con-
trol code is
detected.
High impedance looping
coaxial video connectors.
www.sennetech.net