background image

4

High Address

Low Address

Set to match the lowest
camera address to which
the code translator will
respond

Set to match the highest
camera address to which
the code translator will
respond

The code translator will appear as a group of cameras to the controller. To prevent interference
between the responses from the code translator and any Vicon cameras in the system, set the
switches to exclude any Vicon camera addresses.

The chart on the following page shows the switch configuration for each address.

If the Vicon controller can be configured to operate in simplex mode, the response line is not
required. Then the address switches can be set to include the maximum 128 VCL addresses.

To set the configuration switches, remove the back panel, which is secured by two screws. Then
slide the cover back to expose the switches. The switches can be changed while the code trans-
lator is powered up and the new settings will take effect immediately.

SETTING THE SWITCHES

U11

U10

U9

U8

U13

U7

U6

U3

U5

U4

CN7

CN6

CN5

CN4

CN3

CN2

CN1

U2

U1

SW4

SW1

SW2

SENNETECH

55-9702

Switch4-1

Vicon Baud Rate

 On:  9600 Baud
 Off:  4800 Baud

Summary of Contents for SCT-1045

Page 1: ...SCT 1045 Ver 1 2 1 CAMERACONTROLCODE TRANSLATOR VICON RS 422 to VCL RS 485 Ver 1 2 SCT 1045 www sennetech net Sennetech Inc 6455 W Bath Rd Perry MI 48872 U S A Ph 517 675 1150 Fax 517 675 1151 ...

Page 2: ...2 ...

Page 3: ...using VCL code from Vicon VPS series controllers It receives Vicon RS 422 commands and transmits the appropriate commands in VCL RS 485 code format There are four independent RS 485 outputs The SCT 1045 will appear to the Vicon controller as a group of responding receiver drivers Internal switches set the low camera number and the high camera number to which the translator will respond The Vicon i...

Page 4: ...e shows the switch configuration for each address If the Vicon controller can be configured to operate in simplex mode the response line is not required Then the address switches can be set to include the maximum 128 VCL addresses To set the configuration switches remove the back panel which is secured by two screws Then slide the cover back to expose the switches The switches can be changed while...

Page 5: ...032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 048 049 050 051 052 053 054 055 056 057 058 059 060 061 062 063 128 064 065 066 067 068 069 070 071 072 073 074 075 076 077 078 079 080 081 082 083 084 085 086 087 088 089 090 091 092 093 094 095 096 097 098 099 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 ...

Page 6: ... out Connect to Vicon response line in if needed Connect to power supply REARPANEL INSTALLATION To install the case on the rack mount frame remove the front panel and the plastic bezel The rack mount frame takes the place of the bezel as shown below VCLDATAOUTPUTS VICON CMD IN RSP OUT POWER 9V to 15V AC or DC S S S S S S VICON Power Tx Rx CODE TRANSLATOR ...

Page 7: ...CL com mands Other commands are converted according to the following table Vicon VCL A P Auto Pan On A I Auto Iris On L S Auto Focus On Aux1 Pan 180 Degrees Aux2 Washer On Aux3 Washer Off Aux4 Wiper On Aux5 Wiper Off Aux6 Manual Change Over Presets Run PP 1 99 Seek Preset 1 99 Pgm PP 1 99 Define Preset 1 99 ...

Page 8: ...8 December 2008 SCT 1045 Ver 1 2 ...

Reviews: