4
High Address
Low Address
Set to match the lowest
camera address to which
the code translator will
respond
Set to match the highest
camera address to which
the code translator will
respond
The code translator will appear as a group of cameras to the controller. To prevent interference
between the responses from the code translator and any Vicon cameras in the system, set the
switches to exclude any Vicon camera addresses.
The chart on the following page shows the switch configuration for each address.
If the Vicon controller can be configured to operate in simplex mode, the response line is not
required. Then the address switches can be set to include the maximum 128 VCL addresses.
To set the configuration switches, remove the back panel, which is secured by two screws. Then
slide the cover back to expose the switches. The switches can be changed while the code trans-
lator is powered up and the new settings will take effect immediately.
SETTING THE SWITCHES
U11
U10
U9
U8
U13
U7
U6
U3
U5
U4
CN7
CN6
CN5
CN4
CN3
CN2
CN1
U2
U1
SW4
SW1
SW2
SENNETECH
55-9702
Switch4-1
Vicon Baud Rate
On: 9600 Baud
Off: 4800 Baud
Summary of Contents for SCT-1045