SENKO P 10 AIR Instruction Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SN-EN-7/15 

PELLET STOVES 

P 7 AIR

 

 7 kW 

P 10 AIR

 

 10 kW 

Summary of Contents for P 10 AIR

Page 1: ...SN EN 7 15 PELLET STOVES P 7 AIR 7 kW P 10 AIR 10 kW...

Page 2: ...re using the stove SENKO management This pellet stove is designed according to the following Directives 89 106 EEC Construction Products Directive 89 366 EEC 2004 108 EEC 2006 95 EEC Low Voltage Direc...

Page 3: ...LUE PIPES 17 4 5 2 CHIMNEY 22 4 5 3 CHIMNEY PREPARATION AND CONTROL 23 4 5 4 CHIMNEY CAP 24 4 5 5 CHIMNEY FUNCTION 26 5 HANDLING THE STOVE 27 5 1 PRE IGNITION WARNINGS 27 5 2 LOADING THE PELLETS 29 5...

Page 4: ...R INFO MENU 49 5 12 ALARMS 50 6 CLEANING AND MAINTENANCE 53 6 1 BURNER POT 53 6 2 HEAT EXCHANGER 54 6 3 ASH PAN 55 6 4 DOOR GLASS 56 6 5 EXTERNAL SURFACE 56 6 6 PELLET TANK 57 6 7 FIREBOX DOOR GASKET...

Page 5: ...n and the use of protective heat insulated gloves is compulsory during handling Children and infirm individuals are not allowed to handle the stove The external appearance of the stove is shown on the...

Page 6: ...control panel E Remote control power supply cable F OK17 igniter key G Burner pot H Handle for closing the pellet tank I Ash pan J PVC feet with screw K Instruction manual CAUTION The stove weighs ov...

Page 7: ...ntion must be paid to electric connections especially bare conduit sections which must not in any way leave the wire grips thus avoiding direct contact with the conduit d The stove must not be install...

Page 8: ...ry must be replaced by original spare parts made exclusively by the manufacturer failure to install original parts results in void warranty j In order to maintain product functionality and to protect...

Page 9: ...enings are necessary for proper combustion Minimum combustion air opening is 10 cm x 10 cm or a hole with approximate diameter of 12 cm During regular stove operation firebox door must be closed at al...

Page 10: ...lue gases temperature measurement probe in case of excessive flue gases temperature max 240 C the probe automatically resets the stove to normal temperature values minimum power level 1 i e fire 1 on...

Page 11: ...termine pellet quality They must by cylindrical with a constant diameter and must have a shiny surface Their diameter must be 5 6 mm and their length 10 40 mm There mustn t be too much sawdust or dust...

Page 12: ...y preventing the egress of ash and smoke into the heated area Firebox door are hermetically sealed THE KEY 1 Chimney connection 80 2 Space heating air filter only in some models 3 Activation switch wi...

Page 13: ...SENKO pellet AIR stoves Instruction manual 12 4 INSTALLATION 4 1 RECOMMENDATIONS Figure 3...

Page 14: ...g of the stove and the chimney which must comply with Prohibitions concerning the installation Safety distances Limitation prescribed by the local administrative regulations or special safety measures...

Page 15: ...from the walls and the furniture figure 4 If the floor is made of flammable material e g wooden parquet it must be protected with a single plate made of non flammable material which must be placed und...

Page 16: ...ctive type ventilation pipes When the afore mentioned devices are located in the adjoining rooms which are in contact with the room where SENKO pellet stove is installed it is forbidden to use these d...

Page 17: ...must not be used as a bedroom bathroom or any space where fire may occur e g garage woodshed flammable material storage room and similar If the air necessary for combustion is sucked via pipes directl...

Page 18: ...eter 4 5 CONNECTING TO CHIMNEY 4 5 1 FLUE PIPES When installing chimney elements made from non flammable materials which are suitable and resistant to combustion products and their potential condensat...

Page 19: ...inspection and cleaning hatch 3 External chimney made of insulated stainless steel pipes 80mm minimum diameter The entire construction must be safely installed onto the wall and must have a protective...

Page 20: ...cap with rain and wind protection Insulated chimney Insulated chimney T connection with inspection hatch Insulated T connection with inspection hatch Installation with internal smoke pipeline unutarn...

Page 21: ...eeding 120 mm are not suitable for direct connection to the stove and a suitable 80 mm diameter flexible smoke venting pipe made from acid resistant stainless material is to be conducted through such...

Page 22: ...y cap with rain and wind protection Chimney cap with rain and wind protection Steel sheet with closed chamber T connection with inspection hatch T connection with inspection hatch Insulated T connecti...

Page 23: ...not allowed to install devices for manual regulation of suction onto devices for forceful suction 4 5 2 CHIMNEY The chimney must meet the following requirements Be impermeable to combustion products w...

Page 24: ...ow the entry point into the smoke venting channel thus allowing for easy opening and inspection via impermeable hatch 4 5 3 CHIMNEY PREPARATION AND CONTROL Prior to stove installation it is necessary...

Page 25: ...uted tightly and impermeably Smoke venting pipe must not penetrate into the chimney clear opening shaft figure 14c Differences between the proper and improper connection of stove to the chimney are di...

Page 26: ...r pressure occurs here Therefore it is necessary to adhere to limitations listed in figure 15 mechanical appliances for flue gases suction are not allowed Roof slope Distance between the roof ridge an...

Page 27: ...the chimney is properly installed Descending wind ALWAYS has the effect of decreasing the draught overpressure occurs Apart from wind direction and velocity chimney position in relation to the house...

Page 28: ...ey situated on the opposite side D from the wind direction 5 HANDLING THE STOVE 5 1 PRE IGNITION WARNINGS During the first several times the stove is activated we advise you to adhere to following rec...

Page 29: ...are hermetically sealed make sure that the power cable is properly connected backside switch must be set to 1 It is of the utmost importance not to increase the heating power to maximum already in th...

Page 30: ...ets the scoop or bag must not come into contact with the hot stove Do not pour any other fuel other than pellets compliant with norms mentioned in chapter 2 into the tank 5 3 CONTROL PANEL KEY 1 param...

Page 31: ...eating temperature TEMPERATURE manual or automatic mode MANU AUTO etc Each of these 4 keys has its assigned function i e they directly refer to words displayed on the screen in the immediate vicinity...

Page 32: ...control away from children Prior to remote control initial use the protective foil must be removed from the back side If you wish to replace empty battery it is necessary to pull out the battery holde...

Page 33: ...the backside of the stove After connecting the power supply cable onto the backside of the stove set the switch to position I As soon as the switch turns on the power supply the control panel should p...

Page 34: ...tatus with active functions table 5 and active alarm if there is one Function Displayed options Current stove status IGNITION ON SHUT DOWN OFF SHUT DOWN AFTER BLACKOUT IGNITION AFTER BLACKOUT Chrono m...

Page 35: ...n in the previous figure descriptions of functions appear on the screen 1 Operating mode selection key Mode changes the operating mode from manual to automatic MANU AUTO 2 Pressing the menu key Menu e...

Page 36: ...ve made must be confirmed by pressing key 3 Ok otherwise the change will not be saved By pressing key 1 Esc you can return to the previous menu without saving the changes Should you not press any key...

Page 37: ...tion status OR The first attempt to activate the stove may not be successful since the pellet feeder spiral is completely empty at the beginning and does not distribute the same quantity of pellets in...

Page 38: ...e function prior to the activation of the stove this function can be found in SETTINGS menu under Charge Pellet after activating pellet dosage it is necessary to wait for several minutes until the pel...

Page 39: ...oling stage OFF appears on the display stove turned off If you want to reduce the shutdown duration of the stove which was working on power 1 Fire 1 until shutdown before switching off the stove you m...

Page 40: ...must activate the thermostat in the technical menu The stove will automatically change the heating power to keep the set room temperature constant Warm air ventilator speed changes automatically to a...

Page 41: ...urrent room temperature is 15 C and you have set the temperature on the control panel to 20 C the stove will operate on maximum heating power Fire 5 Once the 20 C temperature is reached the stove is d...

Page 42: ...insulated rooms with insignificant heat loses 5 7 4 WARM AIR FAN FAN As previously mentioned the stove is equipped with a warm air ventilator which heats the space through grid on the stove front sid...

Page 43: ...irst value you can set is 15 50 and the maximum is 23 h and 50 min after the current time This function is set similarly to the previously described stove Eco operating mode Once this function is set...

Page 44: ...the 6 available programmes is executed in a new menu with the list of parameters as described in the following table In order to activate each daily schedule start and stop hours need to be set in ord...

Page 45: ...you can programme only ascending hours but NOT descending before using the Chrono function you should set the current day and hour if you still haven t following instructions in chapter 5 5 1 for the...

Page 46: ...s is available on the control panel Each profile is defined with start stop times per particular days Once you have selected a particular profile you can freely change all the parameters that define i...

Page 47: ...in menu includes a list of information and parameters and it is used just like the main menu The following table lists various options in the order they appear on the screen together with their values...

Page 48: ...0 minutes After that remove the pellets from the firebox and weigh them on the kitchen scale If the pellet quantity deviates from the default factory setting table 11 it is necessary to undertake dosa...

Page 49: ...re listed in the following table Function Value Temporary States Activations regulating pellet dosage during stove activation IGNITION 5 5 Power States Activations regulating pellet dosage during regu...

Page 50: ...r 2000 working hours on the display will appear the message Warning OR Service which means that it is necessary to make a complete service on the stove from the service technician you must get a CONFI...

Page 51: ...stove automatically shuts down In this situation it is not possible to access the start menu and the stove status cannot be altered before issuing an order to unblock the alarm The bottom line on the...

Page 52: ...eder spiral A02 Flame Shut Down pellet feeder running dry or clogged flue gases ventilator excessive speed lack of fuel in the firebox Fill pellet tank clean the pellet feeder spiral and fill the tank...

Page 53: ...y and flue gas channels connect the stove to a chimney with prescribed diameter check the firebox door and replace the gasket remove all the pellets from the tank and clean the pellet feeder spiral pr...

Page 54: ...y stove activation use appropriate tool to remove the burner pot from the firebox and use a vacuum cleaner with a container to remove the ash Repeat this procedure once a day It is important that the...

Page 55: ...sh deposits accumulate around or on the pot These must be cleaned if necessary using appropriate tools IN CASE OF WEAR DOWN OR DAMAGE IMMEDIATELY REQUEST AN AUTHORIZED MAINTENANCE TECHNICIAN TO REPLAC...

Page 56: ...leaning procedure 6 3 ASH PAN Perform the ash pan cleaning every 2 3 days also depending on the pellet type i e the quantity of produced ash Perform the procedure with a vacuum cleaner with a containe...

Page 57: ...It is possible for glass to become stained during several hours of regular stove operation depending on used pellet type and chimney underpressure In that case clean the glass using a cotton cloth new...

Page 58: ...onsequently proper stove functioning Be sure to periodically control it in case of wear down or damage it needs to be replaced by an authorized individual 6 8 CENTRAL FLUE GAS CHANNEL Central flue gas...

Page 59: ...lts remove the plate located under the lid then remove the turbulators spirals and properly clean them with a brush Figure 43 a b c d e f After cleaning it is necessary to assemble everything in rever...

Page 60: ...RIMARY AIR CHANNEL At the beginning of every heating season control the primary air inlet channel 50 mm on the stove backside for clogging with foreign objects 6 11 FIREBOX Remove the dust or potentia...

Page 61: ...activity the stove must be unplugged and located in a dry environment To ensure even higher level of safety we recommend to disconnect the electric cable from the stove and store it in a safe location...

Page 62: ...et tank External surfaces Central flue gases channel turbulators Igniter support tube Input primary air channel Output flue gas channel chimney Ventilator and pellet feeder motors and other electronic...

Page 63: ...roper pellet dosage firebox polluted primary air inlet channel clogged chimney clogged flue gases ventilator motor malfunctioning fill the pellet tank see previous problem allow the stove to cool comp...

Page 64: ...otor and replace it if necessary The remote control does not work battery empty remote control malfunction replace the battery replace the remote control In automatic mode the stove always operates on...

Page 65: ...0385 40337906 E mail info senko hr podrska senko hr WE D LIKE TO TAKE THIS OPPORTUNITY TO REMIND YOU WHAT YOU NEED TO POSSES WHEN CONTACTING OUR COMPLAINT AND SUPPORT SERVICE Before you contact us pre...

Page 66: ...Nm 3 119 103 110 105 Emission of CO2 in flue gases at Pnom 10 13 8 34 Emission of CO2 in flue gases at Pmin 6 55 6 16 Mean flue gas temperature at Pnom C 144 133 Mean flue gas temperature at Pmin C 98...

Page 67: ...to the manufacturer the product will be replaced with a new one The manufacturer will notify the client about the executed repairs The client is obligated to take over the product within 5 days from t...

Page 68: ...______ WARRANTY SHEET Faulty product date of receipt __________________________ Malfunction description client _____________________________ _________________________ Servicing agency comments _______...

Page 69: ...___ Telephone _____________________ Country ____________________ Date ______________ Client signature _________________________ Chimney Type Dimensions mm Height m Underpressure Pa Flue gases exit tem...

Page 70: ...Pnom 0 013 0 016 CO emission in flue gases by 13 O2 at Pmin 0 011 0 012 Efficiency at Pnom 91 27 90 85 Efficiency at Pmin 92 03 91 57 Fuel type wood pellets Fuel consumption 1 6 kg h 2 3 kg h Certific...

Page 71: ...____________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____...

Page 72: ...Fax 385 0 40 337 906 E Mail info senko hr THE SPIRIT OF TRADITION IN MODERN FORMS FOR A HEALTHY ENVIRONMENT You can find this Manual at http en senko hr If you have any suggestions on how to improve...