SENKO E 2375 D Instruction Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

Solid fuel 
COOK ERS 

SG- 60,  S G- 75 and S G - 90 

SN-EN-9/16 

Summary of Contents for E 2375 D

Page 1: ...Solid fuel COOKERS SG 60 SG 75 and SG 90 SN EN 9 16...

Page 2: ...to its minutest details in order to fulfill your every need for functionality and safety This Instruction manual will teach you to operate your cooker properly so please read the manual carefully bef...

Page 3: ...NG 14 4 2 CHIMNEY PREPARATION AND CONTROL 16 4 3 CONNECTING TO CHIMNEY 16 4 4 FRESH AIR VENTS 20 4 5 OVEN THERMOMETER 22 4 6 INSTALLATION TESTING 22 5 HANDLING THE PRODUCT 23 5 1 DIRECTING THE FLUE GA...

Page 4: ...HANNEL 31 6 1 1 COOKERS SG 75 and SG 90 31 6 1 2 COOKER SG 60 32 7 MAINTENANCE 33 7 1 OLD COOKER DISPOSAL 33 7 2 SPARE PARTS 33 8 MALFUNCTIONS CAUSES SOLUTIONS 34 9 TECHNICAL SUPPORT 35 10 TECHNICAL D...

Page 5: ...ctive heat insulated gloves is compulsory during handling Children and infirm individuals are not allowed to handle the cooker The external appearance of the cooker is shown on the first page of this...

Page 6: ...ned in order to prevent tumbling or damages The standard delivered cooker set consists from cooker instruction manual chimney terminal extension 22 cooker cleaning tool 23 CAUTION The cooker weighs be...

Page 7: ...gy content at approx 4 4 kWh kg 1 2 FEEDING manually when necessary we recommend the logs to be of 50 x 50 mm vertical cut up to 2 3 of the firebox length use smaller logs for a more intensive fire an...

Page 8: ...ding to EN 13384 and all other standards for the chimney dimensioning The chimney has a very important function of the smoke exhaust at solid fuel heating devices and therefore MUST BE well and proper...

Page 9: ...the flue gases and the outer chimney air there is another type of pressure wind dynamic pressure Roof slope Distance between the roof ridge and the chimney Minimum chimney height measured from the ro...

Page 10: ...pressure both inside and outside the residential area Figure 4 Pressure that facilitates chimney function can occur in rooms directly exposed to the wind B but it can also adversely affect the chimney...

Page 11: ...ney fire close the openings for the air inlet and DON T open the firebox door Extinguish the fire using appropriate fire extinguishers NEVER EXTINGUISH A FIRE WITH WATER In case of fire also call the...

Page 12: ...g plate 1 is made of 8 mm thick steel plate Cooker interior is lined with chamotte The fuel box 12 is on the frontal side at the bottom just above the manual primary air regulator 10 and the ash box 1...

Page 13: ...Oven thermometer SCHEMATIC DISPLAY FOR COOKERS SG 75 and 90 THE KEY 1 Cooking plate 2 Frame 3 Cooker base with screws for height adjustment 4 Cooker housing 5 Lower door 6 Firebox door 7 Oven with do...

Page 14: ...n with door 8 Oven door hinge 9 Cleaning hatch lid 10 Primary air manual regulator 11 Ash box 12 Fuel box 13 Chimney connection point 14 Flue gas deflector 16 Firebox grate 17 Oven door glass 18 Oven...

Page 15: ...le objects such as wood chipboard cork and similar If the materials are easily combustible such as PVC polyurethane and similar the necessary safety distances need to be doubled The minimum distance f...

Page 16: ...direct contact with exterior air It is recommended to place the cooker as close as possible to the chimney hole i e next to the chimney hole itself in order to avoid using an additional smoke uptake...

Page 17: ...manufacturer e g for flue draught of 12 Pa the diameter is usually 130 mm The chimney must be smooth on the inside well insulated and well fastened All cleaning hatches must be well fastened All gaske...

Page 18: ...SENKO cookers SG Instruction manual 17 Differences between the proper and improper connection of the cooker to the chimney Figure 6...

Page 19: ...SENKO cookers SG Instruction manual 18 Differences between the proper and improper connection of the cooker to the chimney Figure 6...

Page 20: ...heet metal of the rosette and external lid which are at the beginning removed from the cooker as excess Connect the cooker to the chimney using a sliding rosette 120 mm in diameter Specially designed...

Page 21: ...of fresh air into the room The minimum dimension of the vent must be 6 cm 2 per kW of nominal power e g for 30 kW 180 cm 2 10 x 18 cm vent A pipe can also be installed on the existing opening 110x55mm...

Page 22: ...rmed with tested chimney systems A chimney calculation is mandatory here D Combustion air supply directly from outdoor With an air supply directly through the outside wall the combustion air is only s...

Page 23: ...be checked for blockages once a year by the local qualified chimney sweep To facilitate this appropriate inspection doors should be provided Please consult your local qualified chimney sweep regardin...

Page 24: ...pliance 5 1 DIRECTING THE FLUE GAS Flue gas deflector 14 accelerates the expulsion of flue gas from the cooker when this is necessary It is primarily used during initial stages of firing or when large...

Page 25: ...mum slit to max maximum slit min manual regulator is closed and there is no primary air flow max primary air opening is completely open and the flow is at its maximum NOTE some cooker models have the...

Page 26: ...mbustion reducing harmful substances to ashes and discharging flue gas with low capacity for pollution into the chimney Regulation of secondary air is automatic through the holes that are located in c...

Page 27: ...he firebox and ignite it close the firebox door 6 monitor flame progression through the firebox door once the fire is in full flame add wooden logs as necessary close the flue gas deflector 14 regulat...

Page 28: ...energetic efficiency 5 4 3 ADDING FUEL Apart from use of appropriate fuel and satisfactory chimney flue draught the manner in which the cooker is fuelled also influences the glass cleanness We recomm...

Page 29: ...ease in outdoor temperature can cause chimney malfunction decreased chimney flue draught resulting with not all flue gases being expelled into the atmosphere It is therefore recommended to use less fu...

Page 30: ...res up to 400 C 5 6 FUEL BOX Fuel box 12 is mounted on the guide bars Maximum bearing capacity of the box is 15 kg The box is removed as follows pull the box towards yourself all the way lift the box...

Page 31: ...n accordance with safety procedure The glass 20 on the upper firebox door 6 should be cleaned as necessary using the soot and grease cleaning agent The oven 7 should be cleaned after every instance of...

Page 32: ...remove the manual regulator PVC wheel 10 by pulling it towards yourself open the fuel box 12 remove the cleaning hatch lid 9 Figure 17a remove the protective lid by unscrewing the 4 screws Figure 17b...

Page 33: ...remove the grate 16 from the firebox Figure 18a by unscrewing the 4 screws remove the protective lid and clean the area underneath Figure 18b remove the oven door according to chapter 5 5 and the fuel...

Page 34: ...e to moisture on the plate it may appear the layer of rust Stainless material on the cookers is susceptible to slight colour change due to high temperatures Stainless materials are to be maintained ex...

Page 35: ...ng direction upper or lower door opened inadequate flue draught faulty regulation clean the chimney clean the cooker unclog and clean the chimney use fuel in accordance with chapter 1 1 set the grate...

Page 36: ...e grate as required 9 TECHNICAL SUPPORT Dear client If you were unable to find the solution to the malfunctions that potentially developed while using your product in the table above please feel free...

Page 37: ...h mm 360 330 400 Oven height mm 200 270 230 Oven depth mm 440 Ash pan L 3 2 2 5 Fuel box L 13 3 25 4 41 1 Flue gases exhaust mm 120 Flue gas temperature C 215 260 235 Required flue draught Pa 12 CO in...

Page 38: ...a new one The manufacturer will notify the client about the executed repairs The client is obligated to take over the product within 5 days from the repair completion COSTS The manufacturer does not d...

Page 39: ..._________ WARRANTY Faulty product date of receipt _______________________________ Malfunction description client _______________________________ _______________________________ _______________________...

Page 40: ...Country ___________________________ Date ________________ Client signature ______________________________ Chimney Type Dimensions mm Height m Draught Pa Flue gases exit temperature C Last inspection d...

Page 41: ...lue gases temperature 260 C 235 C Heat output space 7 5 kW Efficiency 72 Fuel type wood logs wood briquettes Fuel consumption 2 kg h Certificate No E 30 00434 12 Read and follow the Instruction manual...

Page 42: ..._________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________...

Page 43: ...SENKO kamini Uputstvo za upotrebu 5...

Page 44: ...SENKO kamini Uputstvo za upotrebu 6 THE SPIRIT OF TRADITION IN MODERN FORMS FOR A HEALTHY ENVIRONMENT You can find this Manual at http en senko hr...

Reviews: