background image

 
 

 

 

Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MI003419 

MI00252-3 

SENECA s.r.l. 

Via Austria 26, PADOVA 

– ITALY  

Tel. +39.049.8705355 

– 8705359 Fax. +39.049.8706287 

Web site: 

www.seneca.it   

Technical assistance: 

[email protected]

 (IT), 

[email protected]

 

(Other)

 

Commercial reference: 

[email protected]

 (IT), 

[email protected]

 

(Other)

 

 

This document is property of SENECA srl. Duplication and reprodution are forbidden, if not authorized. Contents of the present 
documentation refers to products and technologies described in it. All technical data contained in the document may be modified 
without prior notice Content of this documentation is subject to periodical revision. 

To use the product safely and effectively, read carefully the following instructions before use. The product must be used only for the use 
for which it was designed and built. Any other use must be considered with full responsibility of the user. The installation, 
programmation and set-up is allowed only for authorized operators; these ones must be people physically and intellectually suitable. 
Set up must be performed only after a correct installation and the user must perform every operation described in the installation 
manual carefully. Seneca is not considered liable of failure, breakdown, accident caused for ignorance or failure to apply the indicated 
requirements. Seneca is not considered liable of any unauthorized changes. Seneca reserves the right to modify the device, for any 
commercial or construction requirements, without the obligation to promptly update the reference manuals. 

No liability for the contents of this documents can be accepted. Use the concepts, examples and other content at your own risk. There 
may be errors and inaccuracies in this document, that may of course be damaging to your system. Proceed with caution, and although 
this is highly unlikely, the author(s) do not take any responsibility for that. Technical features subject to change without notice. 

USER MANUAL 

Z-D-IN 

 

Summary of Contents for Z-D-IN

Page 1: ...The installation programmation and set up is allowed only for authorized operators these ones must be people physically and intellectually suitable Set up must be performed only after a correct installation and the user must perform every operation described in the installation manual carefully Seneca is not considered liable of failure breakdown accident caused for ignorance or failure to apply t...

Page 2: ...USER MANUAL Z D IN 2 Date Revision Notes 03 08 2016 2 Rewriting 13 01 2022 3 Corrected the bytes of register 40010 ...

Page 3: ... SENECA Z D IN 4 1 INTRODUCTION 5 1 1 FEATURES 5 2 FEATURES 5 3 INPUT CONNECTIONS 7 4 DIP SWITCHES TABLE 8 5 MODBUS RTU PROTOCOL 9 5 1 ABBREVIATION USED 9 5 2 MODBUS REGISTER ADDRESSES 10 6 LEDS FOR SIGNALLING 14 7 FILTER 14 8 EASY SETUP 15 ...

Page 4: ...NCIDENTAL DAMAGE DUE TO NEGLECT OR RECKLESS MISHANDLING OF Z D IN EVEN THOUGH SENECA IS WELL AWARE OF THESE POSSIBLE DAMAGES SENECA ITS SUBSIDIARIES AFFILIATES COMPANIES OF THE GROUP ITS SUPPLIERS AND RETAILERS SHALL NOT GUARANTEE THAT THE FUNCTIONS WILL SATISFY COMPLETELY CUSTOMER S EXPECTATIONS OR THAT Z D IN THE FIRMWARE AND THE SOFTWARE SHALL HAVE NO ERRORS OR WORK CONTINUOUSLY ...

Page 5: ... digital signals with max frequency equal to 100 Hz for 16bit registers the signal is acquired from IN1 4 10kHz for 32bit register IN5 Node address and baud rate configurable from Dip Switches RS485 serial communication with MODBUS RTU protocol 2 Features INPUT Number 5 Filter Configurable between 1 ms and 250 ms Sensor closed The sensor is detected closed if acquired signal voltage 12 Vdc and acq...

Page 6: ...r 19 28 Vac 50Hz 60Hz Power consumption Min 0 5W Max 2 5W The power supply transformer necessary to supply the module must comply with EN60742 Isolated transformers and safety transformers requirements To protect the power supply is recommended to install a fuse ...

Page 7: ...USER MANUAL Z D IN 7 3 Input connections Power on the module with 40 Vdc or 28 Vac voltage supply These upper limits must not be exceeded to avoid serious damage to the module ...

Page 8: ...ans Dip Switch 1 ON state BAUD RATE Dip Switches DIP SWITCH STATUS 1 2 Meaning Baud rate 9600 Baud Baud rate 19200 Baud Baud rate 38400 Baud Baud rate 57600 Baud ADDRESS Dip Switches DIP SWITCH STATUS 3 4 5 6 7 8 Meaning Address and Baud Rate are acquired from memory EEPROM Address 1 Address 2 Address 3 Address 4 X X X X X X Address 63 RS485 TERMINATOR Dip Switches DIP SWITCH STATUS 9 10 Meaning R...

Page 9: ...modbus org specs php 5 1 Abbreviation used In the following table this abbreviations are used MS Most significant LS Less significant MSB Most significant Bit LSB Less significant Bit MSW Most significant Word 16 bits LSW Less significant Word 16 bits R Read only register RW Read and write register Unsigned 16 bits Unsigned 16 bits register Signed 16 bits 16 bits register with sign Float 32 bits F...

Page 10: ... status Bit 2 IN3 status Bit 3 IN4 status Bit 4 IN5 status For example if the register value is 29 decimal MSB 0000 0000 0001 1101 LSB binary IN1 1 IN2 0 IN3 1 IN4 1 IN5 1 Bit 8 Overflow Underflow Counter 1 Bit 9 Overflow Underflow Counter 2 Bit 10 Overflow Underflow Counter 3 Bit 11 Overflow Underflow Counter 4 Bit 12 Overflow Underflow Counter 5 Overflow Underflow bits are set from the firmware ...

Page 11: ...from 0 to 65535 The value is stored into a non volatile RAM FeRAM The Counter value can be written If configured to 32 bit use the registers 40019 LSW 40020 MSW Unsigne d 16 bits R W Non volatile 40007 6 Filter Filter from 1 to 254 in ms applied to all input signals except IN5 if bit7 of the register 40009 is 1 Limit values if 1 ms filtering noise with frequency 1kHz max frequency allowed 1KHz if ...

Page 12: ...y EEPROM The content of 40008 40009 40010 registers is overwritten respectively in the 40072 40073 40074 registers these ones are in memory EEPROM Bit 1 if written to 1 Reset Command Bit 2 15 Not used Unsigne d 16 bits R W 0 40011 10 FW Revision Firmware internal code Unsigne d 16 bits R 40013 12 Counter 1 copy 16 bit counter from 0 to 65535 The value is stored into a non volatile RAM FeRAM The Co...

Page 13: ...t counter from 0 to 65535 The value is stored into a non volatile RAM FeRAM The Counter value can be written Unsigne d 16 bits R W Non volatile 40018 17 Counter 5 32 bit mode 32 bit counter from 0 to 4294967295 The value is stored into a non volatile RAM FeRAM The Counter value can be written Unsigne d 16 bits R W Non volatile 40019 LSW 40020 MSW 18 19 ...

Page 14: ...ilure RX Constant light Verify if the bus connection is corrected Blinking light The module received a data packet TX Blinking light The module sent a data packet Constant light Verify if the bus connection is corrected 1 5 Constant light IN1 5 state equal to 1 No light IN1 5 state equal to 0 if the power is on 7 Filter LPF1 action Input filter Cut off frequency equal to 100Hz for IN1 5 LPF2 actio...

Page 15: ...USER MANUAL Z D IN 15 8 EASY SETUP To configure the Z D IN download the Easy Setup PC software from the Seneca Website http www seneca it en linee di prodotto software easy easy setup ...