User Manual
R-GWR SERIES
ALL RIGHTS RESERVED. NO PART OF THIS PUBLICATION MAY
BE REPRODUCED WITHOUT PRIOR PERMISSION.
www.seneca.it
Doc: MI00568-1-EN
Page 17
BATTERY LIFE
5.
Battery life depends on:
the type of installation.
the type of configuration.
the temperature.
how good the battery is.
how good the radio link is.
The following table is calculated as follows:
without sensor input connections
at a temperature of 20°C
with signal transmitted at 15 dB (maximum power)
SENSOR
TYPICAL
BATTERY
CAPACITY AT
20°C
MAXIMUM ESTIMATED LIFE
SENDING EVERY
60 MIN
SENDING
EVERY 30 MIN
SENDING
EVERY 15 MIN
SENDING
EVERY 10
MIN
SENDING
EVERY 1
MIN
R-GWR-S-1
CR2
900 mAh
Up to 680 days
Up to 500
days
Up to 320 days Up to 230
days
Up to 28
days
R-GWR-IP-1
CR123A
1650 mAh
Up to 1280 days Up to 920
days
Up to 590 days Up to 430
days
Up to 52
days
RESETTING THE DEVICE TO FACTORY CONFIGURATION
6.
It is possible to reset the device to the factory configuration using the following procedure:
1)
With the device off, set dip switch SW2 dip 1 and 2 to ON
2)
Power up the device and wait 10 seconds
3)
Turn off the device
4)
With the device off, set dip switch SW2 dip 1 and 2 to OFF
5)
Power up the device
6)