TD140-038.11 | Version 1.1 | 22 March 2019
4.3 Reading the IP address in the front display
The IP address of the SENEC.Home Li provides information on how the SENEC.Home Li is connected to the network.
IP address
Explanation
192.168.xxx.xxx or 10.xxx.xxx.xxx
SENEC.Home Li is connected to the customer's network (e.g. behind a router or profes
-
sional network).
Network error or NPU fault
Network error
4.4 Reading status indicators on the front display
Status indicator
Meaning
BMS shutdown
The lithium modules were disconnected for safety's sake.
Battery empty
Normal operating status/grid operation The SENEC storage unit will charge when an
excess of PV generation is available.
Battery full
Normal operating status/grid operation The SENEC storage unit can discharge as needed.
Off
The SENEC storage unit was switched off via the display.
DC-switch off
DC isolating switch has been switched off.
Self-consumption
The PV generation covers the current house consumption. The SENEC storage unit is
neither charged nor discharged.
Discharge
Normal operating status/grid operation
Initial charge
First charge after initialisation of the SENEC storage unit.
Remote shutdown
The system is switched off remotely. Operation is discontinued until the disconnection has
been remedied.
Initial state
The SENEC storage unit has not been configured yet and is commissioned for the first
time.
Capacity test: discharge
A capacity test is running and the battery modules will be discharged
Capacity test: charge
A capacity test is running and the battery modules will be charged
Charge
Normal operating status/grid operation
Absorption phase
Normal operating status/grid operation The battery is practically fully charged and is
being charged at lower power until it is detected to be "Fully charged".
Lithium safe mode active
The lithium modules are brought to a pre-set charge status in order to perform jobs such
as module expansions. For this purpose, the system uses the generation and home con
-
sumption.
Lithium safe mode done
The lithium modules have reached a pre-set charge status and are now waiting for the
termination of the safety mode.
Grid + discharge
In normal operating status/grid operation. The house consumption is covered by the
mains supply and battery discharging.
Grid initialization
The system initialises according to the grid. The output of the inverter decreases slowly.
Grid stabilization
The system stabilises according to the grid. The inverter output decreases, as needed.