Technical Manual
Absolute Single/Multiturn Encoders
Profibus
R.000.000
18-19 of 22
1
1
7
7
D
D
e
e
f
f
a
a
u
u
l
l
t
t
s
s
e
e
t
t
t
t
i
i
n
n
g
g
s
s
o
o
n
n
d
d
e
e
l
l
i
i
v
v
e
e
r
r
y
y
On
delivery
the
following
parameters
have
been
factory
set.
Description
Setting
Switch
Baud
rate
automatic
Not
available
Node
address
63
Switch
setting
3Fh
(63)*
*At
closed
housings
the
switch
is
set
to
the
preorded
node
address
or
to
0xFF
for
“set
station
address”
with
software
Termination
OFF
Switch
setting
off
Index
(hex)
Name
Standard
value
Encoder
Profile
Set_prm
9
Operating
Parameter
Bit
3
Scaling
on
Class
2
on
/CW
Set_prm
10
‐
13
Measuring
Units
per
Revolution
8192
(13
Bit)
Set_prm
14
‐
17
Total
Measuring
Range
33554432
(25
Bit)
The
original
Standard
Values
(
Default
values
on
delivery
)
can
be
reloaded
by
pressing
the
button
on
the
rear
when
switching
on
(Restore
parameters).
If
errors
have
occurred
during
programming
of
the
objects
and
if
these
parameters
have
been
saved
in
the
EEPROM,
it
will
not
be
possible
to
address
the
encoder
next
time
it
is
switched
on;
this
error
can
be
cleared
only
by
means
of
a
general
Reset
of
the
encoder.
18
8
General
Reset
of
the
device
1
General Reset of the device
Please
note
that
all
programmed
parameters
will
be
lost.
•
Switch
the
encoder
off.
•
Turn
the
encoder
back
on,
keeping
the
SET
‐
Key*
pressed
for
approx.
3
sec.
until
the
DIAG
LED
flashes
•
Switch
the
device
off
again
When
the
encoder
is
rebooted
all
values
will
be
reset
to
their
default
settings.
(SSA
‐
address
is
125)
*only
for
devices
with
an
external
SET
‐
Key;
in
other
cases
the
device
should
be
returned
to
the
factory.