6.1
Main
6.1.1
Main — Summary
The intention of this page, together with the
alarm list
, is to provide enough information for the operator
to immediately see if there is anything seriously wrong with one or more input streams.
At the very top, a graphic is displayed representing the front panel of the probe, indicating the status of
the different inputs.
Below this display, the following parameters are shown:
NTP/timesync
(Bulb):
The NTP/timesync bulb indicates whether the VB330 clock is locked to an external time
reference signal. Green indicates that the VB330 is locked to an external reference
whereas gray indicates that the VB330 runs in unlocked mode.
Updated:
The time since the last time synchronization update.
Freq offset:
Indicates the measured frequency offset for the system clock.
Timezone:
The time zone as selected by the operator in the
view.