Make sure
Management
is enabled (set to true) – otherwise management via web will not be possible.
To configure the data/video interface, enter values for data_ipa, data_mask, data_gateway or alternatively
enable data_dhcp. Set data_management to true to enable web access via the data interface.
When all the listed parameters have been configured, the probe must be rebooted to let the parameters
take effect. This is achieved by selecting the
reboot
option and confirming by selecting ‘t’ for TRUE.
4.8.3
Verifying Correct Initial Setup of the 10G Probe
Once the probe management network interface have been configured, all further configuration takes
place using a web browser over HTTP.
Launch a web browser application on the management PC. The following web browsers are supported:
•
Microsoft Edge
•
Microsoft Internet Explorer 11 or higher
•
Mozilla Firefox 29 or higher
•
Google Chrome
•
Apple Safari
Type the IP address of the probe in the browser URL field and press
Enter
. The IP address of the
probe is that of the eth0 or eth1 port (the one used for management) as set in the initial set-up procedure.
The default management view should be displayed inside the browser. This could look similar to figure 4.9,
depending on the options installed.
4.8.4
Initial Setup Troubleshooting
If there are problems bringing up the probe web-based management interface, verify the following:
•
Verify that the laptop and the probe are configured on the same subnet and that they have different
addresses. The network settings of the probe can be verified through RS232/USB as described
earlier
•
Make sure that the IP address of the gateway and the network interface are not the same
•
Verify that the appropriate Ethernet link indicators of the PC and probe are lit
•
Verify that web browser proxy settings are not interfering
•
Verify that local firewall settings on the laptop are not interfering
24
VB3xx 10G Probe User’s Manual version 5.3
Summary of Contents for VB330
Page 1: ...VB3xx 10G Probes Applies to software release v5 3 Form 8046E February 2017...
Page 7: ...F Appendix Restoring probe factory defaults 203 VB3xx 10G Probe User s Manual version 5 3 7...
Page 29: ...VB3xx 10G Probe User s Manual version 5 3 29...
Page 30: ...6 THE 10G PROBE GRAPHICAL USER INTERFACE 30 VB3xx 10G Probe User s Manual version 5 3...
Page 101: ...VB3xx 10G Probe User s Manual version 5 3 101...