background image

 

 
 

Parani-ESD100/110 

 

User Guide 

 
 
 
 
 

 

Version 2.0.6.2 

 

2017-01-26 

Summary of Contents for Parani-ESD100

Page 1: ...Parani ESD100 110 User Guide Version 2 0 6 2 2017 01 26...

Page 2: ...mmended Electrical shock may result Do not kink or crease the power cable or place heavy objects on the power cable Fire can result from damaged power cables Do not handle power plug and adapter with...

Page 3: ...3 2010 09 03 Yh Moon Update Table 3 3 V2 0 4 2011 01 31 Jh Park Add remote configuration V2 0 4 1 2011 12 26 HR Zo Package does not contain CD ROM V2 0 5 2012 01 18 Jh Park Modify contents about page...

Page 4: ...Multi Wizard 24 3 10 ParaniUpdater 25 3 11 Terminal Program 26 4 Multiple Connection Mode 28 4 1 Overview 28 4 2 Configuration 29 4 3 AT Commands 30 4 3 1 AT MULTI n 30 4 3 2 AT MLIST 30 4 3 3 ATHx AT...

Page 5: ...ATOx ATObdaddr 45 B 3 16 AT BTCANCEL 45 B 3 17 AT BTSCAN 45 B 3 18 AT BTSCAN n to 46 B 3 19 AT BTSCAN112233445566 to 46 B 3 20 ATD 46 B 3 21 ATD112233445566 46 B 3 22 ATA 47 B 3 23 ATA112233445566 47...

Page 6: ...Power Timeout default 5 55 C 26 S54 BD Address of Last Connected Device 55 C 27 TS55 BD Address of Last Connected Device 55 C 28 S56 BD Address of Last Connected Device 55 C 29 S57 Slave Disconnect T...

Page 7: ...s the Parani ESD minimize radio interference while decreasing the likelihood of over air hijacking Parani ESD also supports authentication and Bluetooth data encryption Parani ESD can be configured an...

Page 8: ...EDR Profile Serial Port Profile Class 1 Working distance Parani ESD100 Nominal 100m Parani ESD110 Stub Antenna 1dBi Stub Antenna 1dBi 100 meters Stub Antenna 1dBi Dipole Antenna 3dBi 150 meters Dipol...

Page 9: ...rial console cable for configuration included in the Starter Kit package One PC with RS232 serial port Terminal emulation program running on the PC 2 1 Panel Layout This section describes the panel la...

Page 10: ...Figure 2 2 Connecting Parani ESD to Development Board 2 2 2 Connecting Power to Development Board Connect the power plug to the power connector of the Development Board for the Parani ESD using the DC...

Page 11: ...Development Board Connect the serial data cable between the Development Board and the serial device If necessary supply power to the serial device attached to the Development Board Figure 2 4 Connecti...

Page 12: ...Mode1 Parani ESD tries to connect the last connected Bluetooth device Parani ESD in Mode1 is to be a master and tries to connect the last connected Bluetooth device Parani ESD always stores the BD add...

Page 13: ...ESD malfunction consequently In order to prevent this buffer overflow Parani ESD works as follows When using hardware flow control Parani ESD disables RTS so that it stops receiving any further data f...

Page 14: ...3 7 ParaniWIN ParaniWIN is a program that runs on Microsoft Windows for the configuration of Parani ESD Install ParaniWIN on your computer Plug a Parani ESD into the serial port of the computer and tu...

Page 15: ...15 Figure 3 2 Main Window Figure 3 3 Information Window...

Page 16: ...set can be executed or operation mode and RS232 can be configured as well Security option also can be configured in this window Figure 3 5 Device Setting Window Parani ESD supports two security option...

Page 17: ...CONNECT and DISCONNECT In some cases these responses can affect the host system unexpectedly To prevent this user can set the Command response to ON or OFF Click Apply button to apply any changes made...

Page 18: ...the STOP button at anytime in order to terminate the signal strength test The signal strength test will continue until the STOP button is pushed If you close the ParaniWIN Window without pushing the...

Page 19: ...ample we will refer to the two Parani ESDs as ESD1 and ESD2 respectively To use this menu please do the following Step 1 Connect ESD1 and then push the START button Step 2 Disconnect ESD1 connect ESD2...

Page 20: ...connection with Bluetooth devices other than Parani ESD use ParaniWIN or AT commands on a terminal program In this example we will refer to the two Parani ESD s as ESD1 and ESD2 respectively Install a...

Page 21: ...SD1 from the host computer remember to leave the ESD1 powered on Now plug ESD2 into the serial port of the host computer and power on the unit Figure 3 12 ParaniWizard Step 3 Click Wizard Setting butt...

Page 22: ...uetooth devices for 30 seconds The program will show the Bluetooth devices with Device Address Device Name and CoD Class of Device Figure 3 14 ParaniWizard Step 5 Select the ESD1 from the list and cli...

Page 23: ...etween ESD1 and ESD2 the proper operation mode of ESD1 and ESD2 have to be set Figure 3 16 ParaniWizard Step 7 Set the operation mode of ESD2 to Mode1 Figure 3 17 ParaniWizard Step 8 Remove the ESD2 f...

Page 24: ...when the units are turned off and then turned on again they will make an automatic connection to each other 3 9 Parani Multi Wizard Parani Multi Wizard is the software tool for multiple connection mod...

Page 25: ...m the Slave settings The Auto Fill button will load the existing multiple connection mode settings from the Parani SD ESD connected which can be useful when only some parts of the settings are changed...

Page 26: ...start setting control panel add remove programs For more precise details on HyperTerminal installations please refer to Microsoft Windows Help section Attach Parani ESD to serial port of host compute...

Page 27: ...p and select the Echo typed characters locally option For expanded AT commands please refer to Appendix A AT commands Example of AT commands at OK at btinfo 000195000144 ESD100V2_v2 0 0 000144 MODE0 S...

Page 28: ...time and they transfer data bi directionally as in Figure 4 1 M S1 S4 S3 S2 Figure 4 2 Node Switching Mode In Node Switching Mode the master unit maintains multiple connections with maximum 4 slave un...

Page 29: ...matic Connection ATD000195000001 CONNECT000195000001 OK ATD000195000002 CONNECT000195000002 OK ATD000195000003 CONNECT000195000003 OK ATD000195000004 CONNECT000195000004 ATS46 000195000001 OK ATS54 00...

Page 30: ...onnect the slave which belongs to the TASK x ATHbdaddr ATH000195000001 Disconnect the slave with specified BD address 4 3 4 ATOx ATObdaddr Using the ATO command the communication status with the last...

Page 31: ...tions The master unit would try to connect all slave units specified by S register 46 54 55 and 56 If non existing or inactive slave addresses are entered in these S registers the overall performance...

Page 32: ...television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by on or more of the following measures Reorient or relocate...

Page 33: ...Certification No MSIP CRM SNA IW06 5 4 TELEC Technical Regulations for Specified Radio Equipmen Article 2 Section 1 19 Certification No 011 160055 5 5 SIG QDID B016862 Core Spec Version 2 0 2 0 EDR Li...

Page 34: ...equency Shift Keying 2Mbps 4 DQPSK pi 4 rotated Differential Quaternary Phase Shift Keying 3Mbps 8DPSK 8 phase Differential Phase Shift Keying 6 5 Radio Output Power Products Radio Output Power Parani...

Page 35: ...put UART Data Input TTL 4 RTS Output UART Ready to Send TTL 5 CTS Input UART Clear to Send TTL 6 VDD Input DC Input 3 0 3 3V Power 7 Pairing Input Pairing Input Active Low TTL 8 DCD Output Bluetooth C...

Page 36: ...air of Parani ESD s like virtual serial cable Note During the pairing process by way of the pairing signal the Command Response will be deactivated Thus the Parani ESD will not send the response messa...

Page 37: ...Master Caution When you are designing a new hardware you must maintain the pull up status by hardware for pairing signals If pairing signals are floating by hardware unexpected errors may occur A 2 C...

Page 38: ...RXD CTS RTS RST DTR DSR MICOM TXD MICOM GND VDD GND DCD DC 3 3V PARANI ESD A 2 1 3 When TTL level of MICOM is 5V MICOM MICRO VDD MICOM RXD MICOM CTS MICOM RTS MICOM RST MICOM DTR MICOM DSR TXD RXD CT...

Page 39: ...39...

Page 40: ...4 kinds of message OK ERROR CONNECT and DISCONNECT B 1 3 Operation Mode Mode Description Mode0 Waiting for AT commands Mode1 Attempting to connect to the last connected Bluetooth device Mode2 Waiting...

Page 41: ...ion 5 6 7 8 9 10 AT BTINFO AT BTINQ AT BTLAST AT BTVER AT BTRSSI n AT MLIST Mode 11 12 AT BTMODE n AT MULTI n Status 13 14 15 16 17 18 19 AT SETESC nn ATO AT BTCANCEL AT BTSCAN AT BTSCAN n to AT BTSCA...

Page 42: ...of Parani ESD must be same as those of host equipment If not the Parani ESD will not respond or ERROR message will appear or an abnormal sequence of strings will appear B 3 4 AT UARTCONFIG Baudrate Pa...

Page 43: ...um 15 devices are scanned for 30 seconds Default 15 value in S register 24 B 3 7 AT BTLAST Response 112233445566 Purpose Display the BD address of the last connected device Description The Bluetooth d...

Page 44: ...change the status to Standby with AT BTCANCEL prior to this command To take effect the ATZ must be executed or Powercycle the unit Example AT BTMODE 2 OK ATZ B 3 12 AT MULTI n Response n 0 OK n 1 or n...

Page 45: ...Convert the operation status of Standby to Connect Description You can convert the operation status of Standby to Connect ready to transmit data In Node Switching mode a specific slave can be specifie...

Page 46: ...66 to Response OK CONNECT 112233445566 or OK ERROR Purpose Wait for connection by the Bluetooth device with given BD address Parameters 112233445566 BD address to time duration in seconds Description...

Page 47: ...address Parameters 112233445566 BD address Description Parani ESD attempts to ACL connect to the Bluetooth device with the given BD address To make successful ACL connection the Bluetooth device must...

Page 48: ...e Clear the list of Bluetooth devices sharing the same pin code Description This clears the list of Bluetooth devices linked with the same key in flash memory To take effect the ATZ command must be us...

Page 49: ...e Parani ESD out of low power mode B 3 32 AT PASS string Response Remote Configuration Enabled Purpose Input password in remote configuration mode Parameters string Password Default 0000 Description I...

Page 50: ...value of S register Description Some S registers are optimized for the overall performance and protected and cannot be changed When users try to change these S registers response is ERROR For details...

Page 51: ...nnnn AT BTINFO AT BTLPM n AT BTSD AT BTCSD AT BTFP n AT UARTCONFIG b p s h AT BTVER AT BTRSSI n AT PASS nnnnnnnn AT CHPASS nnnnnnnn Valid only when Parani ESD is not connected to other Bluetooth devic...

Page 52: ...iving data is 2 Kbytes C 3 S4 Enable Remote Name Query default 1 S4 0 Parani ESD will query only the BD address This speeds up the inquiry process S4 1 Parani ESD will query the BD address device name...

Page 53: ...hether Bluetooth connection is released when DTR signal drops or not If this value is 1 you can use DTR signal in order to disconnect Bluetooth connection C 11 S22 Faster Connection default 3 S22 0 no...

Page 54: ...ally The smaller the value becomes the more quickly Parani SD can detect an abnormal disconnection But when the communication is suspended it may be regarded as disconnection This value should be grea...

Page 55: ...ed Device This saves the Task3 BD address of the Bluetooth device connected most recently in a multiple connection mode C 28 S56 BD Address of Last Connected Device This saves the Task4 BD address of...

Page 56: ...4 0 means the maser unit never connected to a slave The master will connect to a slave whatever responses first C 32 S60 Reconnect Time Interval default 5 This value defines reconnect time interval in...

Page 57: ...Response Message The messages of Parani ESD response may affect the function of host system Set ATS10 0 not to send Parani ESD response to host system and try again Refer Appendix B for details D 3 Tr...

Page 58: ...GES INCLUDING BUT NOT LIMITED TO DIRECT INDIRECT INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES WHETHER IN AN ACTION IN CONTRACT OR TORT INCLUDING NEGLIGENCE AND STRICT LIABILITY SUCH AS BUT NOT LIMITED...

Page 59: ...ry component capacity degradation due to usage aging and with some chemistry lack of maintenance E 4 SOFTWARE PRODUCT WARRANTY DETAILS WARRANTY PERIOD SENA warranties software Product for a period of...

Page 60: ...60 Appendix F How to make a RS232 interface Development Board...

Page 61: ...61 Appendix G Parani ESD100 110 PCB mechanical drawing...