1257 Salt Springs Rd.
Youngstown, OH 44509-1612
Phone: (800) 239 -1226
Fax: (801) 697-0825
People Counter with Data Recorder
Page 1 of 5
PC-RSBX05
Description:
When installed as explained below, the photoelectric sensor and the reflector generate an invisible beam
of light that travels across a maximum distance of 5 meters (~16ft) between sensor and reflector. When a
person crosses the beam breaking the “A” sensor first a digital signal is sent to the counter incrementing
it’s display by +1. This unit counts up only when people are entering (people exiting are ignored). This
system operates with a safe low voltage 24V DC supply (included).
Components:
o
2 Retroreflective Photoelectric Sensors With 10ft Cable (W25xH65xL75mm)
o
2 Reflectors (40.5x60.5mm).
o
24V DC Power Supply With 10ft Cable
o
Count Recorder
o
Chime
(optional)
Maintenance
:
Occasionally it may be necessary to wipe the lens of the reflectors and sensors clean from debris and
dust. Use a soft cotton cloth with a mild detergent.
Support:
For technical assistance please call 330.792.7089
Installation:
By following the simple guidelines below your people counter will be operating within a few minutes.
1. Adding Cable Length
Skip this step if you plan on using the standard 10ft cable provided.
You may use your own cable (according to the specifications listed in figure 3) if you wish to extend the
distance from the components (up to 1000ft with shielded cable). To remove the sensor covers, loosen
the screw on each sensor housing and pull the tops off. If removed, replace the sensor covers and
screw them back into place.
2. Wiring Components
Connect the wires from the sensors, power supply, count recorder, and chime (optional) to the terminal
strip according to the wiring diagram, while adhering to the wiring codes established for your state and
locality. Excess wire length can be trimmed. Please follow the included instructions with the count
recorder along with the wiring guide in figure 3.
Refer to Figures 1, 2, and 3
Refer to Figure 3