The “PGA” controls should then look like the picture below.
17.6
ZoomingADC™ Configuration
17.6.1 Zooming on the Signal
As the sensor is supposed to work at the atmospheric pressure (max: 107.8kPa - min: 88.7kPa) we will zoom
on around these values and thus use the maximum amplification as possible to get the full signal at the ADC
input.
As for zoom in pictures we set a particular zone of interest called measuring window (in red below).
17.6.2 Gain Computing
To compute the total gain that must be applied to the sensor output signal we must know 2 parameters:
1. The maximum output span of the ADC, here 3.3V
2. The maximum output span value of the sensor in the measuring window, here around 8.5-4.5 = 4mV
Figure 37. SX8724S “PGA” Group of Controls Configuration
Figure 38. Zooming on the Signal