© by SEMIKRON / 2020-05-25 / Technical Explanation / SKYPER
®
12 PV
PROMGT.1026/ Rev.7/ Template Technical Explanation
Page 33/37
8.
Environmental conditions
Table 11: SKYPER
12 PV | Environmental conditions
Insulation parameters
Rating
Norm / Standard
Grid voltage
690V
IEC 61800-5-1
Pollution Degree
PD II
IEC 61800-5-1
Maximum altitude
2000 meter above sea
IEC 61800-5-1
Overvoltage category
OVC III
IEC 61800-5-1
Isolation resistance test,
primary to secondary side
(2 pieces per lot as series test, power and signal
transformers are 100% tested as series test)
5000 V AC rms, 60s
IEC 61800-5-1
Rated insulation voltage
8 kV Cat. III
IEC 60664-1
Partial discharge
2.2kV/1.8kV
IEC 61800-5-1
Creepage distance
primary to secondary side
20.9mm
IEC 61800-5-1
Clearance distance
primary to secondary side
14.0mm
IEC 61800-5-1
Creepage distance
secondary to secondary sides
10.5mm
IEC 61800-5-1
Clearance distance
secondary to secondary
6.1mm
IEC 61800-5-1
CTI rating of the PCB
II (400-600)
IEC 61800-5-1
CTI of the transformers
I (600)
IEC 61800-5-1
Climate
Rating
Norm / Standard
Climate class
3K3
IEC 60721-3-3
Environmental conditions
Rating
Norm / Standard
Operating/storage temperature
-40... +85 °C
High humidity
85 °C, 85%
Flammability
Heavy flammable materials only
UL94 V0
RoHS / WEEE /
China RoHS