5.8
Safe short circuit turn-off in multilevel topology
Semiconductors in multilevel NPC applications need to be controlled carefully, especially in certain short
circuit conditions. A proper turn-off sequence must be maintained to avoid damage to the semiconductors
due to over voltage. The integrated DSCP, Soft Off and active clamping features ensures that the SKYPER
42 LJ R allows the control of the semiconductors in multilevel applications. And thanks to the advanced
error management provisions have been taken to allow the application controller to safely handle even
short circuit conditions.
Detailed information using the SKYPER
42 LJ R driver core in multilevel applications can be found in the
Application Note AN19-001 “Gate Driver Configuration and Short Circuit Protection for 3-Level Topologies”.
Thoroughly reading this document is highly recommended before starting tests of multilevel topologies.
6.
Electrical characteristic
Figure 22: SKYPER
42 LJ R | Maximum switching frequency