1. Introduction

Study this manual carefully and keep it with the 
warranty documents. Connection must be carried 
out by a qualified fitter in accordance with local 
regulations. Before mounting or dismounting 
the thermostat, always switch off the electricity 
in the meter cupboard. This thermostat can be 
mounted in a single flush-mounting box 50 mm 
deep in accordance with standard DIN formats. 
These regulations describe the C16 Basic and the 
C16 WiFi version.

2. Technical Specifications 

Voltage 

  

: 230V - 50/60 Hz

Max. load    

: Max. 16 Amp / 230V

Standby voltage 

 : C16 Basic: 1W / C16 WiFi: 2W

Temp. range  

: +5/+40ºC

Housing    

: IP21 

Standard colour  

: Polar white (RAL 9010) 

Sensor 

 

 : Floor sensor and build in Air sensor

Warranty   

: 2 years manufacturer’s warranty

Approvals    

: FI / CE 

Manufacturer  

: MHGroup B.V. Netherlands 

3. Assembly

1. 

Press with your fingers at the top of the display and pull it towards you.

2. 

Connect the thermostat according to the connection diagram (point 4).

3. 

Mount the thermostat on the flush-mounting box.

4. 

Put the frame on it and click the display back into place.

4. Wiring diagram

Connection must be carried out by a qualified fitter in accordance with local regulations. 
Before mounting or dismounting the thermostat, always switch off the electricity in the 
meter cupboard. 

Recommendation: Keep the maximum load around 90% of the 16A to extend the service 
life.

FLOOR SENSOR : Floor sensor connection
ROOM OUT SENSOR: External room sensor 
connection

N1  Heating cable connection wire*
L1 

Heating cable connection wire*

N  

Power supply (Neutral)

L  

Power supply (Phase) 

EARTH : Connect the earth of the heating 
cable and the earth of the power supply 
outside the thermostat using the supplied 
terminal block.

* Order L1 or N1 does not apply.

5. Explanation of symbols

When the thermostat is connected, turn the on/off switch down to turn the 
thermostat on. The thermostat is operated by means of the 3 touch-sensitive buttons 
on the bottom of the screen and has a series of fixed symbols in the display. 

6. Startup menu 

At the first startup, the following settings need to be entered. With the WiFi version it 
will be updated automatically after connection.

Clock (CLK)

Choose Day                                Choose Hour 

               Choose Minutes  

Sensor selection

 (5 options)

1. 

Floor sensor

2. 

Room sensor

3. 

Room sensor with floor sensor limit

4. 

External room sensor

5. 

External room sensor with floor sensor limit

3.  Limit floor temperature

For tiled floors up to 35 degrees.  PLEASE NOTE: For wooden floors set to a maximum 
of 28 degrees!

4. Home or office situation (00 = Home, 01 = Office)

C16

WiFi / Basic

(WiFi) thermostat for electric floor heating

MAX LOAD:   16A

SENSOR

L1

N1 NL

FLOOR 

SENSOR

POWER

85V-265V 
50/60Hz

IP 21

N1

N

L

L1

S2 COM

S1

POWER

FLOOR SENSOR

ROOM -OUT SENSOR

Display

On/Off switch

Touch sensitive keys

86

86

59

51

52

24

9

12

1.

2.

3.

4.

Confirm (touch-sensitive key)

Down (touch-sensitive key)

Up (touch-sensitive key)

WiFi indicator

Hello

Clock 

Room temperature 

Floor temperature

Set up

Current temperature

Heating

Percentage

Current period (Smart Mode)

Key lock

Frost protection mode

Manual mode

Office

House