Selectronic Australia
Select.live Display Operation
26
OI0009 Revision 01 Select.live User Manual
The screen switches between Screen 1 and Screen 2 every 2 seconds. The backlight of the
LCD display stays off.
Note: if the SP PRO has an active event, the screen is overridden by the event
screen as shown in Section 5.4 (page 28).
Parameter
Description
CLOUD
The connection status to the portal.
CLOUD: OK
–
the device is connected to the portal (has an
internet connection)
CLOUD: ERROR or NO LAN
–
the device is not connected to
the portal (has no internet connection)
IP
IP address of Wi-Fi or Ethernet whichever is selected in
Setup Wizard.
IP: XXX.XXX.XXX.XXX
–
the device is connected to a
network
IP: Unknown
–
the device is not connected to any network
D.Ver
The firmware version of the device
Device ID
A unique ID that is used for adding the system to the Portal
Serial
Serial of SP PRO, used for adding the system to the Portal
SN
Serial of SP PRO, used for adding the system to the Portal
Rating
The power rating of the SP PRO in Watts
SoC
Real-time State of charge of the battery from SP PRO in %
Grid
Real-time Grid Power of the SP PRO in Watts
Positive value
–
Exporting to the grid
Negative value
–
Importing from Grid
Load
Real-time Load Power of the SP PRO in Watts
Batt
Real-time Battery Power of the SP PRO in Watts
Positive Value
–
Charging the battery
Negative Value
–
Discharging the battery
Solar
Real-time Solar Power of the SP PRO in Watts