INSTRUMENT FOR COVERT ELECTROOPTICAL SURVILLENCE
SYSTEMS DETECTION
«GCU-OSD10»
OPERATING MANUAL
2018
Page 1: ...INSTRUMENT FOR COVERT ELECTROOPTICAL SURVILLENCE SYSTEMS DETECTION GCU OSD10 OPERATING MANUAL 2018...
Page 2: ...arameters 1 2 1 Distance of ESS detection Minimal 2m Maximal 500m 750m 1 2 3 Receiving channel field of view 5 x 3 8 HxV 1 2 4 Maximal azimuth angle of ESS The same as FOV of ESS 1 2 5 Output signal f...
Page 3: ...tissue 1 Package case 1 Operating manual 1 Buttery delivered uncharged Battery mains adapter and charging unit can be replaced by technically similar or better devices The general view of the instrum...
Page 4: ...with the video input PCB to enhance the quality of obtained image The instrument has number of adjustment keys used to control the laser radiation power receiving TV camera sharp ness pseudo binocula...
Page 5: ...ig 4 Fig 4 Example of image obtained with the help of GCU OSD10 Laser switch on button Video cable connector Laser power adjustment Diopter adjustment Switch On off button Battery level indicator Lase...
Page 6: ...ded to perform the battery charging at the ambient temperature from plus 10 to plus 30 2 1 9 It is not allowed to switch on the charging unit under rain or at high humidity 2 1 10 During the Instrumen...
Page 7: ...ush button LASER pressed and perform scanning of area of interest All appeared glowing dots seen within the scanning field limits i e occurring within the area illuminated by laser are considered as r...
Page 8: ...n idle state once a year it should be totally charged and totally discharged after Such charge discharge operations should be repeated once a year for preservation of operability of the battery 5 MANU...