Sekonic LITEMASTER PRO L-478DR-A-PX Startup Manual Download Page 1

1

 Check Included Items

The following items are included with the meter in the package. 

Please be sure that everything is included. If any item is missing, 

please contact the reseller that sold the meter or the distributor.

  Batteries are not included in the package. Please prepare two AAA before 
use. 

Startup Guide

(L-478DR-PX Series)

1

 Check Included Items

The following items are included with the meter in the package. 

Please be sure that everything is included. If any item is missing, 

please contact the reseller that sold the meter or the distributor.

  Batteries are not included in the package. Please prepare two AAA before 
use. 

Startup Guide

(L-478DR-PX Series)

Safety Precaution

CD-ROM

(Operating Manual and 
Data Transfer Software)

Strap

Soft case

Anti-glare sheet for  

LCD Screen

2

 Component

 

Names

The followings are the names of the buttons and parts on the meter. 

Bottom view

Strap eyelet

Synchro terminal

Battery cover open

Battery 

compartment

Front view

Rear view

L-478D

JR10-0000

01

MODEL

SEKONIC CORPOR

ATION

MADE IN  P

HILIPPINES

Lock lever

Touch 
panel

Memory
button*

USB
port

Menu 
button

Lumisphere 
retracting ring

Lumisphere

Measuring
button*

Battery 
cover latch

Power
button

Battery cover

* When using the Spot Meter attachment (separate accessory), you 

Measuring button functions. For details to do this, please see the 
Custom Settings function section in the Operating Manual on the 
included CD-ROM.

3

 Turning the Power ON

After inserting the batteries according to the “+” and “-” symbol in 

the battery compartment, press and hold the Power Button for about 

1 second to start up meter.

* The startup screen will be displayed, followed by the measuring 

screen. 

* Press and hold the Power Button for about 1 second to turn the 

meter off.

Measuring screen

Power Button

Title screen

L-478DR-PX Series

(Phottix)

*Please wait 3 seconds between repeated power on and power off 
sessions.

SEKONIC logo in blue will be displayed as the meter starts up.
*For explanation purpose, the LCDs illustrated here show the displays of 
L-478DR-PX.
 

4

 Screen Operations

This section explains how the touch panel on the meter is operated.

Measuring screen

Sliding:

setting value areas to change setting 
values.

Touch Operations:

Setting value increases when the up arrow (

) is touched.

◆ 

Setting value decreases when the down arrow (

) is touched.

◆ 

Touch icon/buttons on

 

the screen to activate their function.

5

 Measuring Preparations (Selecting Measuring Mode)

This example explains how to measure light using the ambient light 

T value (shutter speed) priority mode.

1)  Touch the Measuring Mode icon at the top left of the Measuring screen to 

enter the Measuring Mode Selection Screen.

Measuring screen

Measuring Mode 

Selection screen

2)  Touch the ambient T icon to select the ambient light T (shutter speed) 

priority mode and return to the Measuring screen.
*  The above screen example shows all of the Measuring Mode visible. 

3)  Set the ISO sensitivity and shutter speed corresponding to the camera 

settings for shooting. 

Shutter speed

ISO sensitivity

6

 Measuring Preparations (Setting Lumisphere)

The Lumisphere can be extended or retracted to obtain the best 

light measurements for different types of subjects. 

Selecting Lumisphere setting 

 Turn the Lumisphere retracting ring to set the aligning mark with the 
corresponding symbol (extended

  

/retracted

  

) until it clicks into 

place.

Extended Lumisphere

Retracted Lumisphere

(Lumidisc)

Extended lumisphere is used to 
measure illumination of people, 
buildings, and other three 
dimensional subjects.

Retracted Lumisphere is used 

subjects such as manuscripts, 
paintings, difference of one or 
more light sources for ratio lighting 
and illumination in Lux or Foot-
candle.

* Models sold in some countries do not display “Foot-candle” due to legal
  restrictions

Extended (

)

Retracted (

)

Extended 
Lumisphere

Lumisphere  
Aligning mark

Retracted 
Lumisphere

 

7

 Measuring Light

This section explains how to take an incident-light measurement 

1) Incident Light

Position the meter in front of the subject with the extended Lumisphere 
facing towards the camera’s lens axis. Press the measuring button to

 

measure the light falling on the subject.

2)

 

desired area to be measured within the yellow circle and press the measuring 

 Safety Precaution

 For Proper Operation

Before using this product, please read this "Safety Precautions" for 

proper operation.

 WARNING

The WARNING symbol indicates the 

possibility of death or serious injury if the 

product is not used properly.

 CAUTION

The CAUTION symbol indicates the 

possibility of minor to moderate personal 

injury or product damage if the product is 

not used properly.

NOTICE

The NOTICE symbol indicates cautions 

or restrictions when using the product. 

Please read all notes to avoid errors in 

operation.

 General Safety Information

  Read the Operating Manual before use.

  Keep the Operating Manual on hand for reference at any 

time.

  Stop using this product when there are any abnormalities.

 

  Do not attempt to repair this product by yourself.

  This product is intended only for persons with expert 

knowledge.

  Monitor children so that they do not touch this product.

  Use this product in a usage environment described in the 

Operating Manual.

  This product is not waterproof.

 WARNING

There is a danger of electrical shock when using high 

voltage strobes.

Avoid contacting the terminals.
This product emits electromagnetic waves.  

Do not bring this product close to persons with 

pacemakers.

Do not use this product in an explosive atmosphere.

Use of devices emitting electromagnetic waves is 

prohibited in hospitals.

 CAUTION

  Check the material of the neck strap to see if there is any 

risk of allergy.

  Be careful of sudden emission of lights from strobes.

NOTICE

  Do not leave this product on car dashboards in hot weather. 

This may damage the product.

  Remove the batteries when this product is not in use for a 

long period of time.

  When the desired performance is not achieved, stop using 

this product and contact the service center.

 Information for Users on Collection and 

Disposal of Old Equipment

  To protect environment, do not through this device 

and batteries away with the normal household waste 

at the end of those life, but bring them in at an 

English

Light Meter

L-478DR-A-PX
L-478DR-U-PX

L-478DR-PX

Please read the operating manual carefully to fully understand the features 

of this product

 

before use and keep it for future use. Keep the operating 

manual in a safe place.

LITEMASTER PRO

Startup Guide

Safety Precaution

CD-ROM

(Operating Manual and 

Data Transfer Software)

Strap

Soft case

Anti-glare sheet for  

LCD Screen

2

 Component

 

Names

The followings are the names of the buttons and parts on the meter. 

Bottom view

Strap eyelet

Synchro terminal

Battery cover open

Battery 

compartment

Front view

Rear view

L-478D

JR10-0000

01

MODEL

SEKONIC CORPOR

ATION

MADE IN  PH

ILIPPINES

Lock lever

Touch 
panel

Memory
button*

USB
port

Menu 
button

Lumisphere 
retracting ring

Lumisphere

Measuring
button*

Battery 
cover latch

Power
button

Battery cover

* When using the Spot Meter attachment (separate accessory), you 

may find operation more comfortable by switching the Memory and 
Measuring button functions. For details to do this, please see the 
Custom Settings function section in the Operating Manual on the 
included CD-ROM.

3

 Turning the Power ON

After inserting the batteries according to the “+” and “-” symbol in 

the battery compartment, press and hold the Power Button for about 

1 second to start up meter.

* The startup screen will be displayed, followed by the measuring 

screen. 

* Press and hold the Power Button for about 1 second to turn the 

meter off.

Measuring screen

Power Button

Title screen

L-478DR-PX Series

(Phottix)

*Please wait 3 seconds between repeated power on and power off 

sessions.

* When first starting or after replacing batteries, a white screen with the 

SEKONIC logo in blue will be displayed as the meter starts up.

*For explanation purpose, the LCDs illustrated here show the displays of 

L-478DR-PX.

 

4

 Screen Operations

This section explains how the touch panel on the meter is operated.

Measuring screen

Sliding:
Slide a finger up or down on the 
setting value areas to change setting 
values.

Touch Operations:

Setting value increases when the up arrow (

) is touched.

Setting value decreases when the down arrow (

) is touched.

Touch icon/buttons on

 

the screen to activate their function.

5

 Measuring Preparations 

(Selecting Measuring Mode)

This example explains how to measure light using the ambient light 

T value (shutter speed) priority mode.

1)  Touch the Measuring Mode icon at the top left of the Measuring screen to 

enter the Measuring Mode Selection Screen.

Measuring screen

Measuring Mode 

Selection screen

2)  Touch the ambient T icon to select the ambient light T (shutter speed) 

priority mode and return to the Measuring screen.

*  The above screen example shows all of the Measuring Mode visible. 

3)  Set the ISO sensitivity and shutter speed corresponding to the camera 

settings for shooting. 

Shutter speed

ISO sensitivity

6

 Measuring Preparations 

(Setting Lumisphere)

The Lumisphere can be extended or retracted to obtain the best 

light measurements for different types of subjects. 

Selecting Lumisphere setting 

 Turn the Lumisphere retracting ring to set the aligning mark with the 
corresponding symbol (extended

  

/retracted

  

) until it clicks into 

place.

Extended Lumisphere

Retracted Lumisphere

(Lumidisc)

Extended lumisphere is used to 
measure illumination of people, 
buildings, and other three 
dimensional subjects.

Retracted Lumisphere is used 
to measure illumination of flat 
subjects such as manuscripts, 
paintings, difference of one or 
more light sources for ratio lighting 
and illumination in Lux or Foot-
candle.

* Models sold in some countries do not display “Foot-candle” due to legal
  restrictions.

Extended (

)

Retracted (

)

Extended 
Lumisphere

Lumisphere  

Aligning mark

Retracted 

Lumisphere

 

7

 Measuring Light

This section explains how to take an incident-light measurement 

using the extended Lumisphere and a reflected-light measurement 

using the optional 5-degree Viewfinder attachment.

1) Incident Light

Position the meter in front of the subject with the extended Lumisphere 
facing towards the camera’s lens axis. Press the measuring button to

 

measure the light falling on the subject.

2)

 

Reflected Light (with 5-degree viewfinder attachment sold separately)
Look through the finder eyepiece from the position of camera, place the 
desired area to be measured within the yellow circle and press the measuring 
button to measure the light reflected from the subject.

 Safety Precaution

 For Proper Operation

Before using this product, please read this "Safety Precautions" for 

proper operation.

 WARNING

The WARNING symbol indicates the 

possibility of death or serious injury if the 

product is not used properly.

 CAUTION

The CAUTION symbol indicates the 

possibility of minor to moderate personal 

injury or product damage if the product is 

not used properly.

NOTICE

The NOTICE symbol indicates cautions 

or restrictions when using the product. 

Please read all notes to avoid errors in 

operation.

 General Safety Information

  Read the Operating Manual before use.

  Keep the Operating Manual on hand for reference at any 

time.

  Stop using this product when there are any abnormalities.

 

  Do not attempt to repair this product by yourself.

  This product is intended only for persons with expert 

knowledge.

  Monitor children so that they do not touch this product.

  Use this product in a usage environment described in the 

Operating Manual.

  This product is not waterproof.

 WARNING

There is a danger of electrical shock when using high 

voltage strobes.

Avoid contacting the terminals.
This product emits electromagnetic waves.  

Do not bring this product close to persons with 

pacemakers.

Do not use this product in an explosive atmosphere.

Use of devices emitting electromagnetic waves is 

prohibited in hospitals.

 CAUTION

  Check the material of the neck strap to see if there is any 

risk of allergy.

  Be careful of sudden emission of lights from strobes.

NOTICE

  Do not leave this product on car dashboards in hot weather. 

This may damage the product.

  Remove the batteries when this product is not in use for a 

long period of time.

  When the desired performance is not achieved, stop using 

this product and contact the service center.

 Information for Users on Collection and 

Disposal of Old Equipment

  To protect environment, do not through this device 

and batteries away with the normal household waste 

at the end of those life, but bring them in at an 

English

Light Meter

L-478DR-A-PX
L-478DR-U-PX

Thank you for purchasing the LITEMASTER PRO L-478DR-PX Series.

This Startup Guide introduces the basic operating functions of this light meter.

For specific details on this light meter, please see the Operating Manual on 

the CD-ROM (included in the package).

LITEMASTER PRO

L-478DR-PX

Startup Guide

Reviews: