Seitron RGDCOHMP11SE Manual Download Page 1

 

 

      

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL FEATURES 

Power supply: 

230V~ -15% +10% 50Hz 

Power absorption: 

6VA 

Contacts rating: 

Sealed relay 6(2)A

 

@

 

250V~

 

SPDT 

Indicators: 

Operation: 

Green led 

 

Alarm: 

Red led 

 

 

Fail: 

Yellow led 

 

 

Alarm: 

Buzzer (after ~15 seconds) 

Activation delay: 

~ 1 minute 

Relay activation delay: 

~ 15 seconds 

Sensor type:   

Electrochemical cell 

Sensor lifetime: 

5 years 

Remote sensor: 

    SGA type 

Detected gas:  

Carbon monoxide (CO) 

Pre-alarm threshold: 

16ppm ± 4ppm 

 

 

(20mg/m³ ± 5mg/m³) 

Main-alarm threshold: 

80ppm ± 20ppm 

 

 

(100mg/m³ ± 25mg/m³) 

Operating temperature: 

0°C .. 40°C 

Storage temperature: 

-10°C .. +50°C  

Humidity limits: 

20% .. 80% RH (non condensing) 

Protection grade: 

IP 42 

Case:  Material: 

ABS V0 self-extinguishing 

 

  Color: 

Cover: 

Signal white (RAL 9003) 

 

 

Details: 

Mouse grey (RAL 7005) 

 

Size: 

 

 

148 x 84 x 40 mm (W x H x D) 

Weight: 

 

 

~ 425 gr. 

 

OPERATION

 

Carbon monoxide (CO) is a gas whose high toxicity (it can have 

severe  consequences  even  when  inhaled  in  very  small 

quantities)  is  added  to  an  extreme  danger  because  it  is  not 

perceptible  by  people  being  colorless  and  odorless.  The 

SEGUGIO (Fig. 1) detector is a microprocessor based electronic 

device that answers all needs of safety in those cases in which 

there  can  be  CO  production  (e.g.  where  heating  or  cooking 

appliances can have uneven combustions). 

Indications are pre-set on three different alarm thresholds: 

1°  THRESHOLD  (Pre-alarm  CO)  =  red  LED  blinks  slowly  and 

the 

relay  1

 turns on (as an example to turn on a light indicator) 

for CO>16 ppm (20mg/m³) concentration. 

2° THRESHOLD (Main-alarm CO) = red LED, buzzer and 

each 

relays

 are turned on for CO>80ppm (100mg/m³) concentration.  

3°  THRESHOLD  (Main-alarm  remote  sensor)  =  red  LED  blinks 

quickly, buzzer and 

each relays

 are turned on. 

The 

relay  2

  can  close  a  gas  distribution  valve,  possible  CO 

generation source and/or turn on a fan to ventilate the room.     

In case of alarm (2° threshold), the relays and buzzer work 

until  the  test/alarm-reset  button  is  depressed,  even  if  CO 

concentration returns below the alarm threshold

.  

The  SEGUGIO  detector  is  equipped  with  a  delay  line  which 

avoids  the  intervention  of  the  alarm  system  (in  order  for  the 

electrochemical  cell  sensor  to  heat  up)  whenever  the  device  is 

turned  on  or  even,  after  a  mains  blackout,  when  the  power 

comes back. During this time delay (about 1 minute), the yellow 

LED is blinking and, at the end, is turned off in order to indicate 

the 'active' state for the detector itself. During normal operation 

the detector samples the CO concentration every 15 seconds. 

The SEGUGIO detector also features an auto-diagnostic system 

for  checking  the  sensor  good  conditions.  When  the  yellow 

indicator is turned on (sensor fail), the possible causes must be 

searched among the following: 

- sensor fail; 

- sensor disconnected; 

- detector malfunctioning. 

A functional test of the overall detector system can be  executed 

pressing the test button: the alarm condition is entered for a few 

seconds  allowing  the  test  of  the  red  led,  the  buzzer  and  the 

relays. 

 

USE INSTRUCTIONS 

In order to reach the wiring zone, remove the plastic plate on the 
cover  as  indicated  in  Fig.  2  and  remove  the  screw  located 
underneath.  
Make electrical wirings as indicated in Fig. 3, 4 or 5.Please note 

ENGLISH

 

that the intervention delay is strictly dependent both on a correct 

positioning of the detector in the room and to the type of gas to 
be detected. In case of 'light' gases as CO an installation in high 

places  is  advisable  (roughly  180  cm.  from  floor).  Please  avoid 
installation in such a position that it can be directly in the stream 

of  smokes  or  vapors  containing  compounds  which  are 

dangerous for the sensor health (as an example: do not position 
the detector in the stream of fat smokes produced by cooking). 

Do not use the following products in the immediate vicinity: 
- silicone  compounds  as,  for  instance,  spray,  aerosols, 

  lubricants, polishers, adhesives, paints, cleansing agents, etc 

- solvents and diluents as, for instance, IPA (isopropyl alcohol), 
  methylbenzene, xylene, ethylene, acetylene, etc.  

Clean the device only using a cloth damped with water. 
 

Warning 

 

 

 

 

 

 

 

 

 

The  installer  shall  complete  and  apply  the  adhesive  label 

supplied with the product reporting the date by which the detector 

must be replaced. This date corresponds to 5 solar years from its 

starting  date.  The  label  must  be  applied  by  the  installer  onto  a 

visible part of the unit in the typical installation position. 

 

 

WARNING

 

-  For  remote  sensor  all  wirings  must  be  made  using 

  wires  with  1.5  mm²  minimum  section  and  no  longer 

  than  25  m.  Do  not  use  same  duct  for  signal  wires  and 

  mains.  

-  The appliance must be wired to the electric mains through 

  a  switch  capable  of  disconnecting  all  poles  compliant  to 

  the  current  safety  standards  and  with  a  contact 

  separation of at least 3 mm in all poles. 

-  Installation  and  electrical  wirings  of  this  appliance  must 

  be made by qualified technicians and in compliance with 

  the current standards. 

-  Before  wiring  the  appliance  be  sure  to  turn  the  mains 

  power off. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARRANTY 

In the view of a constant development of their products, the manufacturer 

reserves the right for changing technical data and features without prior 

notice.  The  consumer  is  guaranteed  against  any  lack  of  conformity 

according  to  the  European  Directive  1999/44/EC  as  well  as  to  the 

manufacturer’s document about the warranty policy. 

The full text of warranty is available on request from the seller.

 

RGDC

OHM

P

1

1

S

E

 0

3

6

1

4

3

 1

4

01

2

WARNING

: in case of CO detection alarm: 

 

 1)  Ventilate  immediately  the  room  opening  doors 

 

and windows. 

 2)  Turn off any functioning combustion device. 

 3)  Search  and  remove  the  possible  cause  of 

 

alarm. 

 4)  In  case  the  cause  of  the  alarm  is  not  immedi

 

ately  removed,  vacate  the  room  and  call  a 

 

qualified technician. 

 

 

      

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MANUFACTURED IN SEITRON S.p.A. - ITALY

 

RGDC

OHM

P

1

1

S

E

 0

3

6

1

4

3

 1

4

01

2

RGDCOHMP11SE     

 

 

RIVELATORE DI MONOSSIDO DI CARBONIO 

 

Sensore a cella elettrochimica

 

 

Alimentazione 230V~  

 

16ppm (20mg/m³) pre-allarme, 80ppm (100mg/m³) allarme 

 

Pulsante di test / reset allarme 

  Ingresso per sensore remoto, tipo SGA --- 

 

CARBON MONOXIDE DETECTOR 

 

Electrochemical cell sensor

 

 

230V~ supply 

 

16ppm (20mg/m³) pre-alarm, 80ppm (100mg/m³) main alarm threshold

 

 

Test / alarm-reset button

 

  Remote sensor input, SGA --- type

 

 

ATTENZIONE 

L'INSTALLAZIONE  DEL  RIVELATORE  DI  GAS  NON  ESONERA  DALL'OSSERVANZA  DI  TUTTE  LE  

REGOLE  RIGUARDANTI  LE  CARATTERISTICHE,  L'INSTALLAZIONE  E  L'USO  DEGLI  APPARECCHI  

A  GAS,  LA  VENTILAZIONE  DEI  LOCALI  E  LO  SCARICO  DEI  PRODOTTI  DELLA  COMBUSTIONE  

PRESCRITTI  DALLE  NORME  UNI  E  DALLE  DISPOSIZIONI  DI  LEGGE. 

 

WARNING 

THE INSTALLATION OF THE DETECTOR DOESN'T EXEMPT FROM THE OBSERVANCE OF ALL RULES 

ABOUT THE CHARACTERISTICS, INSTALLATIONS AND THE USE OF THE GAS DEVICES, THE VENTI-

LATION  OF  THE  ROOMS  AND  THE  EMISSIONS  OF  THE  PRODUCTS  OF  THE  COMBUSTION  PRE-

SCRIBED FROM UNI STANDARDS AND THE PROVISIONS OF THE LAW. 

MONOSSIDO DI CARBONIO

SEGUGIO

CARBON MONOXIDE

Fig

. 1

 

MONOSSIDO DI CARBONIO

SEGUGIO

CARBON MONOXIDE

Fig

. 2

 

Via del Commercio, 9/11 

36065 Mussolente (VI) ITALY 

Tel.:  +39.0424.567842 

Fax.:  +39.0424.567849 

http://www.seitron.it 

e-mail: [email protected]

 

Summary of Contents for RGDCOHMP11SE

Page 1: ...m floor Please avoid installation in such a position that it can be directly in the stream of smokes or vapors containing compounds which are dangerous for the sensor health as an example do not position the detector in the stream of fat smokes produced by cooking Do not use the following products in the immediate vicinity silicone compounds as for instance spray aerosols lubricants polishers adhe...

Page 2: ...llarme Sensore esterno lampeggio veloce del LED rosso attivazione della suoneria e di entrambi i relè Il relè 2 può chiudere una valvola di erogazione del gas eventuale fonte di generazione di CO e o attivare un ventilatore per l aerazione del locale In caso di allarme 2 livello l intervento dei relè e la suoneria persisteranno finchè non verrà premuto il tasto presente sul frontale del dispositiv...

Page 3: ...TALLATION DU DÉTECTEUR DE GAZ NE DISPENSE PAS DE L OBSERVANCE DE TOUTES LES RÉGLEMENTATIONS CONCERNANT LES CARACTÉRISTIQUES L INSTALLATION ET L UTILISATION DES APPAREILS À GAZ LA VENTILATION DES LOCAUX ET L EXPULSION DES PRODUITS DE LA COMBUSTION PRESCRITS PAR LES NORMES UNI ET PAR LES DISPOSITIONS LÉGALES MONOSSIDO DI CARBONIO SEGUGIO CARBON MONOXIDE Fig 1 MONOSSIDO DI CARBONIO SEGUGIO CARBON MON...

Page 4: ...eil est débranché du secteur GARANTIE Dans l optique d un développement continu de ses produits le constructeur se réserve le droit d apporter sans préavis des modifications aux données techniques et aux prestations de ces derniers Selon la Directive Européenne 1999 44 et le document qui reporte la politique de garantie du constructeur le consommateur est protégé contre les défauts de conformité d...

Reviews: