background image

Cal. 5D22, 5D44

 

INSTRUCTIONS 

(P.       3) 

 

BEDIENUNGSANLEITUNG 

(S.    23)

 

INSTRUCTIONS 

(P.     43)

 

ISTRUZIONI 

(P.     63)

 

INSTRUCCIONES 

(P.     83)

 

INSTRUÇÕES 

(P.   103)

 

 

(123      )

1_KINETIC 5D22 5D44_E.indd   1

07.8.22   1:13:29 PM

Summary of Contents for 5D22

Page 1: ...Cal 5D22 5D44 INSTRUCTIONS P 3 BEDIENUNGSANLEITUNG S 23 INSTRUCTIONS P 43 ISTRUZIONI P 63 INSTRUCCIONES P 83 INSTRUÇÕES P 103 123 C 5D22 5D44_E indd 1 07 8 22 1 ...

Page 2: ...Conservez ce mode d emploi pour toute référence ultérieure Grazie di aver acquistato questo orologio SEIKO KINETIC Cal 5D22 5D44 Per ottenerne i migliori risultati leggere attentamente le istruzioni di questo libretto prima di passare all uso dell orologio stesso Tenere poi il manuale a portata di mano per ogni eventuale futura ulteriore consultazione Usted es ahora un orgulloso propietario de un ...

Page 3: ...tion Booklet CONTENTS Page FEATURES 4 DISPLAY AND BUTTON OPERATION 5 CROWN WITH DRIVING WHEEL 7 HOW TO CHARGE AND START THE WATCH 8 HOW TO READ THE DIRECT DRIVE INDICATOR 10 TIME CALENDAR SETTING 17 IMPROPER FUNCTION 19 AUTOMATIC HAND ALIGNMENT 20 POWER SOURCE KINETIC E S U 21 SPECIFICATIONS 22 C 5D22 5D44_E indd 3 07 8 22 1 ...

Page 4: ... drive indicator that constantly displays how long the watch will keep operating The direct drive indicator also dynamically displays the electric power generation status while charging the watch CAUTION The movement of your arm while the watch is worn generates electrical energy to power the watch Even if the watch is worn on your arm it will not be charged while your arm is not in motion It is r...

Page 5: ...amount of power reserved power generation status and amount of generated power Date Day hand retrograde day indicator Minute hand The position of the date window and day hand may differ depending on the model Normal position Electric power generation by manual winding Second hand Button only used for special operations l CAL 5D44 CROWN C 5D22 5D44_E indd 5 07 8 22 1 ...

Page 6: ...ting amount of power reserved power generation status and amount of generated power Date Minute hand Normal position Electric power generation by manual winding Second hand Button only used for special operations l CAL 5D22 CROWN The position of the date window may differ depending on the model C 5D22 5D44_E indd 6 07 8 22 1 ...

Page 7: ...g this type of crown as it should be operated in a different way from that of ordinary ones CROWN WITH DRIVING WHEEL To pull out the crown pull out the A portion crown To turn the crown turn the B portion driving wheel Normal position First click position Second click position Driving wheel Crown A B A B C 5D22 5D44_E indd 7 07 8 22 1 ...

Page 8: ...can also be charged when the crown is turned in a reciprocating motion When the watch is completely stopped the direct drive indicator hand points at scale marking 1 under the 0 position standby position If the second hand does not move even though the crown is turned turn the crown more quickly If the watch has been left untouched for several years the second hand starts moving in 2 second interv...

Page 9: ...l the indicator hand points at the second marking above 0 approximately 6 hours of power reserve This watch will keep on operating for approximately 1 month 30 days if it is fully charged However it is not necessary to charge the watch fully as it is charged automatically while it is worn on your wrist Refer to How to read the direct drive indicator for further details 3 Continue to turn the crown...

Page 10: ...used to check the following 1 Power reserve amount continuous operating time 2 Real time power generation status and newly generated amount of power while charging the watch M 1 position Power reserve generated power scale Standby position Scale marking C 5D22 5D44_E indd 10 07 8 22 1 ...

Page 11: ...ow long the watch will keep operating in 18 steps 0 M scale marking The continuous operating time until approximately one month 30 days can be displayed Real time power indicator While turning the crown to charge the watch the watch checks a newly generated amount of power and displays it in 19 steps 0 M 1 scale marking A maximum 6 hours of generated power can be displayed The real time power indi...

Page 12: ...in 2 H 2 H 20 Min 2 H 40 Min 3 H 3 H 20 Min 3 H 40 Min H Hour D Day W Week The minimum amount of power reserve and g e n e r a t e d p o w e r i s described in the table Scale marking 12 13 14 15 16 17 18 Indication on dial 0 W Week 12 M Month Power reserve amount 5 D 6 D 1 W 2 W 3 W 30 D Amount of generated power 4 H 4 H 20 Min 4 H 40 Min 5 H 5 H 20 Min 5 H 40 Min 6 H Scale table of power reserve...

Page 13: ...ted power Scale marking Power reserve 3 Not shorter than 9 hours and not longer than 12 hours 9 Not shorter than 2 days and not longer than 3 days 17 30 days Scale marking Generated power 3 1 hour or more 9 3 hour or more 18 6 hour or more C 5D22 5D44_E indd 13 07 8 22 1 ...

Page 14: ...seconds After the crown is turned repeatedly the indicator hand will stop at the maximum scale value M 1 position If the crown is turned after the indicator hand stops at the M 1 position the watch continues to accumulate power reserve but stops displaying the power generation status If you want to display the power generation status stop turning the crown and after the indicator hand returns to d...

Page 15: ...erve of 30 days and then it is left untouched the watch will not operate for more than 30 days after it is worn again When you take off the watch and leave it untouched look at the indicator to check if the watch continues to operate until you wear the watch the next time and turn the crown to charge the watch as necessary make sure to store extra power so as not to stop operation of the watch C 5...

Page 16: ...e turning the crown B When temporarily stopping turning the crown After approximately 4 seconds since stopping turning the crown After approximately 1 second since starting to turn the crown A B The power reserve indicator hand points at a scale marking between 0 and M 1 according to power gen eration status The point where the indicator hand starts moving goes up as generated power increases C 5D...

Page 17: ...urs Turn the hand past the 12 o clock marker to deter mine whether the watch is set for the A M or P M period If the calendar changes the time is set for the A M period If the calendar does not change the time is set for the P M period When setting the minute hand advance it 4 to 5 minutes ahead of the desired time and then turn it back to the exact minute 3 Push the crown back in to the normal po...

Page 18: ...and to point at the correct day of the week Do not set the date and day of the week between 9 00 p m and 3 00 a m Other wise it may not change properly It is necessary to adjust the date and day of the week on the first day after a 30 day month and February 4 Push the crown back in to the normal position How to set the date and day day setting only for 5D44 C 5D22 5D44_E indd 18 07 8 22 1 ...

Page 19: ... crown back into the normal position The indicator hand will point at the 0 position and the watch resumes its normal operation IMPROPER FUNCTION When the watch stops operating even though it displays the remainder of the power reserve follow the instructions below to reset the built in IC How to reset the built in IC C 5D22 5D44_E indd 19 07 8 22 1 ...

Page 20: ...nd then set the time date and day of the week AUTOMATIC HAND ALIGNMENT The position of the indicator hand may move out of alignment in rare cases The watch automatically corrects the position of the indicator hand once every 24 hours While correcting the hand position the indicator hand moves abnormally however this is not a malfunction After automatic hand alignment is performed the indicator han...

Page 21: ...om conventional batteries for watches This exclusive secondary battery is an environmentally friendly clean energy storage device CAUTION Never install a silver oxide battery for conventional watches in place of the KINETIC E S U which can generate heat that can cause bursting or ignition POWER SOURCE KINETIC E S U C 5D22 5D44_E indd 21 07 8 22 1 ...

Page 22: ...and day of the week day display only for 5D44 Power reserve display power generation status display and generated power amount display 6 KINETIC electricity storage unit Button type 1 piece 7 Duration of charge Approximately 1 month if the watch is fully charged 8 Additional functions Overcharge prevention function 9 IC Integrated Circuit C MOS IC 1 piece 10 Generating system Miniature AC generato...

Reviews: