20. Parts supplied / Spare parts / Accessories

Description

QTY

Image

 

 

 

Instruction manual

1

 

CE Declaration

1

 

Mounting template

1

 

M6 * 16 bolts

4

A6.4 washer

4

M6 toothed washers

4

Drain pipe

1

Female connector

1

Foam tape

 

Accessories:

Description

Order no.

 

 

Fibre filter media EU2

SP-43040001-O-1

Washable aluminium filter 

SP-43040001-BF-1

Stainless steel filter holder incl. filter media

SP-43040001-BG-1

Door contact switch

3100001

 

Seifert Systems GmbH

Seifert Systems Ltd.

Seifert Systems AG

Seifert Systems GmbH

Seifert Systems Ltd.

Seifert Systems Inc.

Seifert Systems Pty Ltd.

Albert-Einstein-Str. 3

HF09/10 

Wilerstrasse 16

Bärnthal 1

Rep. Office

75 Circuit Drive

105 Lewis Road

 

Hal-Far Industrial Estate

 

 

 

North Kingstown

Wantirna South

42477 Radevormwald

Birzebbuga, BBG 3000

4563 Gerlafingen

4901 Ottnang

26100 Cremona

RI 02852

3152 Victoria

Germany

Malta

Switzerland

Austria

Italy

USA

Australia

Tel.+49 2195 68994-0

Tel.+356 2220 7000

Tel.+41 32 675 35 51

Tel.+43 7676 20712 0

Tel.+39 349 259 4524

Tel.+1 401-294-6960

Tel.+61 3 98 01 19 06

[email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected]

Summary of Contents for 43042001

Page 1: ...6 6 Technical data 7 7 Performance graph 8 8 Mounting 9 9 Condensate management 10 10 Mounting Principle 11 11 Cut Out Dimension 12 12 Dimension H x W x D 13 13 Electrical Connection 14 14 Controller...

Page 2: ...issipation of heat from control cabinets and enclosures stationary not moving in order to protect temperature sensitive components in an industrial environment To meet the conditions of use all the in...

Page 3: ...nits based on the information diagrams or descriptions contained in this manual No liability can be accepted for damage and production caused by Disregarding the instruction manual Operating error Ina...

Page 4: ...regulations One can nd dangerous voltages above 50 V AC or above 100 V DC Behind the control cabinet doors On the power supply in the unit housing The unit has to be operated according to the type pl...

Page 5: ...air does not come into contact with the ambient air which may well be dirty or polluted Enclosure cooling units can dissipate large quantities of heat from sealed enclosures such as electrical enclos...

Page 6: ...e capillary pipe being a much lower pressure the refrigerant arrived to the evaporator where it absorbs the necessary heat to change from liquid to gas state The gas is then drawn back into the compre...

Page 7: ...ystem unimpeded Ambient air circuit 90 250 m h Cabinet air circuit 115 136 m h Mounting External Housing Material Mild steel powder coated Dimensions A x B x C D E 501 6 x 280 x 200 mm Weight 26 kg Cu...

Page 8: ...Version No 1 8 04 06 2022 Doc No 9943042001 8 19 7 Performance graph...

Page 9: ...e case a barrier or duct shall be provided to redirect the air ow Cooling unit enclosure air suction hole must be installed in the highest possible point When installing the unit on a door ensure it c...

Page 10: ...pipe should be attached as required e g in conditions of high humidity To install a drain pipe please follow below steps Remove the plastic stopper from in the base of the unit factory setting is lock...

Page 11: ...No 1 8 04 06 2022 Doc No 9943042001 11 19 10 Mounting Principle Do not use within the rst 15 minutes after installation 1 M6 screws 2 M6 at washers 3 M6 toothed washers 4 Cabinet 5 Sealing tape 6 Cool...

Page 12: ...Version No 1 8 04 06 2022 Doc No 9943042001 12 19 11 Cut Out Dimension...

Page 13: ...Version No 1 8 04 06 2022 Doc No 9943042001 13 19 12 Dimension H x W x D...

Page 14: ...ng to EN60730 1 8 4 A N O 6 4 A N C 2 2 A N O N C 250Vac 100000 cycles UL 873 8A resistive 2FLA 12LRA pilot duty C300 250Vac 30000 cycles These contacts are not suitable for uorescent loads neon light...

Page 15: ...ress Set to save the new setting To change the heating set point St2 units with internal heater only 1 Press Set till St1 appears on the display and release the button 2 Press again Set till St2 appea...

Page 16: ...Version No 1 8 04 06 2022 Doc No 9943042001 16 19 15 Wiring Diagram...

Page 17: ...power supply connector is incorrect Change phases inside power supply connector Unit doesn t cool External and internal fan work compressor does not work Compressor motor electrical failure Have comp...

Page 18: ...ions which meet the following conditions temperature range 40 C to 70 C Relative humidity at 25 C max 95 Returning the unit To avoid transport damage the unit should be returned in the original packin...

Page 19: ...G Seifert Systems GmbH Seifert Systems Ltd Seifert Systems Inc Seifert Systems Pty Ltd Albert Einstein Str 3 HF09 10 Wilerstrasse 16 B rnthal 1 Rep O ce 75 Circuit Drive 105 Lewis Road Hal Far Industr...

Reviews: