2.Thermostat replacement 
Before replacing the thermostat, isolate the equipment from the power supply (pull out mains plug or
connecting cable). Detach the thermostat from its support by unclipping it from the DIN railing and loosening
the 4 connecting cables.
When connecting the new fan make sure that the correct polarity is maintained.

3. Environmental protection
If  the heat exchanger has reached its end of life state, we will dispose it if it is returned to us freight paid. 

4. Maintenance work on the cooling circuit
All the maintenance operations described above should only be carried out by expert personnel. All work on the
cooling circuit should only be carried out at the factory.

13. Transport & Storage

Malfunction due to transport damage. During transport and storage the heat
exchanger must be kept in the position marked on the box and at a temperature
between -40˚C and 70˚C and a relative humidity of max. 95% (at 25°C). Check
the packaging has not been damaged during shipping.
 

Damage to the unit through incorrect transport. Please ensure that all liquid has
been removed prior any transport.

To avoid transport damage the unit should be returned in the original packing or in a packing case and must be
strapped to a pallet. If the unit cannot be returned in the original packing please ensure that:

A space of at least 30 mm must be maintained at all points between the unit and the external packing.
The unit must be firmly fixed in the packing.
The unit must be protected by shock -resistant padding (hard foam corners or cardboard corners).

14. Parts supplied / Spare parts / Accessories

1 x Heat exchanger
1 x User manual
1 x CE Declaration
1 x Condensate pipe
2 x Brass fitting
4 x Screws M6 x 16 DIN 933
4x Washers A6.4 DIN 6769
4 x Tooth lock washers A6.4 DIN 6797

Seifert Systems GmbH

Seifert Systems Ltd.

Seifert Systems AG

Seifert Systems GmbH

Seifert Systems Ltd.

Seifert Systems Inc.

Seifert Systems Pty Ltd.

Albert-Einstein-Str. 3

HF09/10 

Wilerstrasse 16

Bärnthal 1

Rep. Office

75 Circuit Drive

105 Lewis Road

 

Hal-Far Industrial Estate

 

 

 

North Kingstown

Wantirna South

42477 Radevormwald

Birzebbuga, BBG 3000

4563 Gerlafingen

4901 Ottnang

26100 Cremona

RI 02852

3152 Victoria

Germany

Malta

Switzerland

Austria

Italy

USA

Australia

Tel.+49 2195 68994-0

Tel.+356 2220 7000

Tel.+41 32 675 35 51

Tel.+43 7676 20712 0

Tel.+39 349 259 4524

Tel.+1 401-294-6960

Tel.+61 3 98 01 19 06

[email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected]

Summary of Contents for 2300110

Page 1: ...l Regulations 2 3 Safety Instructions 3 4 Settings 4 5 Functional Principle 5 6 Technical Data 6 7 Mounting 7 8 Mounting Principle 9 9 Wiring Diagram 10 10 Taking into Operation 11 11 Maintenance Clea...

Page 2: ...ns in the instruction manual must be adhered to General danger Indicates compulsory safety regulations which are not covered by a speci c pictogram such as one of the following High electric voltage I...

Page 3: ...with regards to Safety instructions Instructions on taking the cabinet out of operation Instructions on the prevention of unauthorised cabinet reconnection The electric equipment meets the valid safe...

Page 4: ...55 P The cooling water used must be soft enough to avoid scale deposits but should not be too soft as this would corrode the heat exchanger Where the cooling water is cooled for reuse part of the wate...

Page 5: ...s constantly providing continuous circulation of the air in the cabinet This circulation prevents hot spots within the control cabinet During this process the coolant heats up and is returned to the c...

Page 6: ...peded 85 240 m h Mounting Wall mounted recessed Housing Material Mild steel powder coated Dimension A x B x C D E 303 x 153 x 84 mm Weight 4 5 kg Voltage Frequency 120 V 60 Hz Starting Current 0 74 A...

Page 7: ...g template enables the unit to be installed quickly For mounting the template should be attached to the wall of the cabinet and the holes for the xing screws should be drilled in the wall of the cabin...

Page 8: ...ion drain pipe should be attached as required e g in conditions of high humidity To install an oel cleaning drain 2 pipe please follow below steps Remove the plastic stopper from in the base of the un...

Page 9: ...Version No 1 4 02 06 2021 Doc No 992300110 9 13 8 Mounting Principle 1 Bolt 2 Toothed washer 3 Washer 4 Enclosure 5 Mounting gasket...

Page 10: ...Version No 1 4 02 06 2021 Doc No 992300110 10 13 9 Wiring Diagram M1 Radial fan X3 3 pin connector L1 Live N Neutral PE Earth protection...

Page 11: ...the unit To set the ow rate Q turn the thermostatic head Set the indicator position to the required cabinet temperature The work s setting of the water ow regulator is 35 C The adjustment range is 20...

Page 12: ...ure If no button is pressed for 60 sec all changes made to the parameters temporarily saved in the RAM will be cancelled and the previous settings restored The cooling unit manufacturer is in no way l...

Page 13: ...ned in the original packing or in a packing case and must be strapped to a pallet If the unit cannot be returned in the original packing please ensure that A space of at least 30 mm must be maintained...

Reviews: