69
10.2.2.VTS CREDIT BOARD OPTION SETTINGS
Credit Board Mode Settings Switch 3
Country
Setting
Switch 3 Setting
Coin Validator Programming
C120/SR3 Only
SW1 SW2 SW3 SW4 SW5 SW6 COIN1 COIN2 COIN3 COIN4 COIN5 COIN6
COIN7 COIN8 COIN9 COIN10 COIN11 COIN12
UK
Coin Controls
C220 Parallel
OFF OFF OFF OFF
£1 50p
new
20p
10p
-
50p
old
-
-
UK
Coin Controls
C220 Binary
ON OFF OFF OFF
£1 50p
new
20p
10p
-
50p
old
-
£2
UK
Coin Controls
C220 Binary
OFF
ON OFF OFF
£1 50p
new
20p
10p
-
£2
-
50p
old
UK
Coin Controls
SR3 Parallel
ON ON OFF OFF
£1 50p
new
20p
10p
-
£2
-
50p
old
- - - -
UK
Euro
Coin Controls
SR3 Parallel
OFF OFF ON OFF
£2
€2
£1
€1
50p new
50¢
20p
20¢
10p
10¢
- - -
50p
old
- - -
UK
Mars ME/MS
111 Parallel
ON OFF ON OFF
£1
£2
20p
10p 50p
new 50p
old
UK
NRI Parallel
OFF
ON
ON
OFF
10p
20p
50p
£1
£2
-
Belgium
Parallel
ON ON ON OFF
-
50BFr 20BFr 5BFr
Holland
Parallel
OFF OFF
OFF ON
-
5NLG 2.5NLG 1NLG
Austria
SR3 Parallel
ON OFF OFF ON
20Sch 10Sch 5Sch
1Sch
Spain
Coin Controls
C220 Binary
OFF
ON OFF ON
500Pta 200Pta 100Pta 50Pta
25Pta
200Pt
old
50Pta old 25Pta old
Spain
SR3/NRI
Parallel
ON ON OFF ON
500Pta 200Pta 100Pta 50Pta
25Pta
-
-
200Pta
-
50Pta old 25Pta old
-
Spain
Coin Controls
C220 Parallel
OFF OFF ON ON
100Pta 50Pta
new
- 25Pta
new
- 50Pta
old
- 25Pta
old
Portugal
Euro
Parallel
ON OFF ON ON
200Es
€1
100Es
50¢
50Es
- - - - -
TBA
OFF
TBA
Please Note
The credit board automatically sets the validator for parallel and binary
operation through an output on pin 8 of the 17 way pinstrip. For the feature
to work it is necessary for the validator interconnecting cable to include at
wire at this position
ON
TBA
Channels
OFF
Direct
Mode
ON
2
channel
Mode
Note: These switch settings are under constant review and may change due to world currency updates.
•
Set SW 1 according to the option settings found in the relevant Price of Play Settings Table on the following pages.
•
For Germany (DM), France (Fr) & Switzerland (SFr), use the appropriate existing setting shown above (from another country) that matches the coin ratios programmed into your coin mech.
•
Set SW 3 on the
VTS
/Excel board as shown in the table above corresponding to the country required.
Summary of Contents for MINI DELUXE THE HOUSE OF THE DEAD 4
Page 74: ...72 11 CONTROLLER UNIT GUN...
Page 76: ...74...
Page 77: ...75...
Page 78: ...76...
Page 79: ...77...
Page 94: ...92 17 5 ASSY MONITOR UK HDF 1070UK...
Page 104: ......
Page 105: ......
Page 106: ......