3.9 Band Scan Mode
1
Diagram
8
Markers information
2
Traces
9
Detailed measurements
3
Markers
10
Frequency and span settings
4
Vertical axis labeling
11
Calibration status
5
Frequency axis labeling
12
Run/Hold status
6
Main menu
13
USB/Battery status
7
Highlighted menu option
The SARK-110 can be used as a rudimentary Spectrum Analyzer in Band Scan Mode. It can be
used to scan for nearby signals that may interfere with the measurements or to measure the
power of the spectrum of signals in a lab environment.
Operation is similar to the Scalar Mode and uses the same frequency settings. There are two
traces: left axis shows the signal power level (Pwr) and right axis shows the peak hold (Peak).
Press the Run/Hold
[
►||
]
button twice to reset the Peak trace at any time.
The sweep speed is slower than in other modes and is largely proportional to the width of the
Span setting. Narrower spans yield faster sweeps.
Save Data and Load Data file operations are not available in this mode, but it is possible to
capture screenshots as in the other modes.