Change Default Facility Code
These procedures will change the default facility code used for codes added on the Wiegand inputs.
Wiegand 1
1251
$
6
$
1
$
106
$
XXX
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter 1 (for Wiegand Input 1). No tone will sound.
Enter next sub mode 106 and listen for good tone.
Enter 3-digit facility code (0 to 255) and listen for good tone.
Enter # key to exit Programming Mode.
Wiegand 2
1251
$
6
$
2
$
106
$
XXX (facility Code)
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter 2 (for Wiegand Input 2). No tone will sound.
Enter next sub mode 106 and listen for good tone.
Enter 3-digit facility code (0 to 255) and listen for good tone.
Enter # key to exit Programming Mode.
Add Split-Relay Access Code on Wiegand Inputs
These procedures will add a split-relay access code or codes for Wiegand keypads, card readers,
remotes, and vehicle tag readers based on the current split-relay configuration as follows:
If split-relay function is configured as W1
$
Relay A, W2
$
Relay A, then split-relay access
codes will be added to Relay A on both Wiegand inputs.
If split-relay function is configured as W1
$
Relay A, W2
$
Relay B, then split-relay access
codes will be added to Relay A on Wiegand Input 1 and Relay B on Wiegand Input 2.
If split-relay function is configured as W1
$
Relay B, W2
$
Relay B, then split-relay access
codes will be added to Relay B on both Wiegand inputs.
Quick Entry for Wiegand Keypad (uses default facility code)
This procedure will add one or more access codes with the default facility code for a Wiegand
keypad. Both the 26-bit and SBI Flex 64-bit formats can be used.
1251
$
6
$
1
$
107
$
1
$
XXXXX
$
#
Enter Master Code (default 1251) and listen for good tone.