Direct Programming Manual
Edge
Smart Keypads and Card Readers
46
If you need help, please email
or call
(972) 474-6390
.
Repeat above step to add additional codes.
Note: Card-to-card swipe timeout is 10 seconds.
Enter # key to exit Programming Mode.
Note: This procedure will not work if any of the following are true:
Wiegand input is set to SBI Flex 64-bit format.
Wiegand input is disabled.
Wiegand input is configured to share code list with non-Wiegand codes.
Split relay feature is enabled.
Add Latch Code(s) to Relay B on Both Wiegand Inputs
These procedures will add a latch code or codes to Relay B for Wiegand keypads, card readers,
remotes, and vehicle tag readers on both Wiegand inputs.
Quick Entry for Wiegand Keypad (uses default facility code)
This procedure will add one or more latch codes with the default facility code for a Wiegand
keypad. Both the 26-bit and SBI Flex 64-bit formats can be used.
1251
$
6
$
105
$
1
$
XXXXX
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter next sub mode 105 and listen for good tone.
Enter next sub mode 1 and listen for good tone.
Enter code (26-bit: 5 digits; numbers only; max value 65535) and listen for good tone.
Repeat above step to add additional codes.
Enter # key to exit Programming Mode.
Note: This procedure will not work if any of the following are true:
One or both Wiegand inputs are disabled.
One or both Wiegand inputs are configured to share code list with non-Wiegand codes.
Each Wiegand input is configured to a different Wiegand bit format.
Split relay feature is enabled.
Quick Entry for Wiegand Card Readers, Remotes, and Vehicle Tag Readers
This procedure will add one or more latch codes with a specified facility code for a Wiegand card
reader, remote, or vehicle tag reader. Only the 26-bit format can be used.
1251
$
6
$
105
$
2
$
XXX
$
XXXXX
$
#
Enter Master Code (default 1251) and listen for good tone.