Direct Programming Manual
Edge
Smart Keypads and Card Readers
30
If you need help, please email
or call
(972) 474-6390
.
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter 1 (for Wiegand Input 1). No tone will sound.
Enter next sub mode 102 and listen for good tone.
Enter next sub mode 4 and listen for good tone.
Scan card to be added twice at reader and listen for good tone.
Repeat above step to add additional codes.
Note: Card-to-card swipe timeout is 10 seconds.
Enter # key to exit Programming Mode.
Note: This procedure will not work if any of the following are true:
Wiegand input is set to SBI Flex 64-bit format.
Wiegand input is disabled.
Wiegand input is configured to share code list with non-Wiegand codes.
Split relay feature is enabled.
Add Sleep Code(s) on Wiegand Input 2
These procedures will add a sleep code or codes for Wiegand keypads, card readers, remotes, and
vehicle tag readers on Wiegand Input 2 only.
Quick Entry for Wiegand Keypad (uses default facility code)
This procedure will add one or more sleep codes with the default facility code for a Wiegand
keypad. Both the 26-bit and SBI Flex 64-bit formats can be used.
1251
$
6
$
2
$
102
$
1
$
XXXXX
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter 2 (for Wiegand Input 2). No tone will sound.
Enter next sub mode 102 and listen for good tone.
Enter next sub mode 1.
Enter code (26-bit: 5 digits; numbers only; max value 65535) and listen for good tone.
Repeat above step to add additional codes.
Enter # key to exit Programming Mode.
Note: This procedure will not work if any of the following are true:
Wiegand input is disabled.
Wiegand input is configured to share code list with non-Wiegand codes.