Edge
Smart Keypads and Card Readers
Direct Programming Manual
If you need help, please email
or call
(972) 474-6390
.
9
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 4 and listen for good tone.
Enter secondary sub mode 7 and listen for audible feedback.
Single tone means feature is enabled.
Double tone means feature is disabled.
Enter 1 (for no change) or 2 (to change current state) and listen for good tone.
Enter # key to exit Programming Mode.
Enable/Disable “3 Strikes, You’re Out”
This procedure will enable or disable “3 Strikes, You’re Out” security. When enabled, the Edge unit
will sound an alarm and go into a 90-second period of lockdown when an incorrect code is entered
three times on the keypad.
1251
$
4
$
8
$
1
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 4 and listen for good tone.
Enter secondary sub mode 8 and listen for status tones.
One tone:
feature is enabled.
Two tones:
feature is disabled.
Enter 1 (for no change) or 2 (to change current state) and listen for good tone.
Enter # key to exit Programming Mode.
Configure Event Input 1
This procedure will enable and configure Event Input 1.
Note: To configure other inputs, use the Edge Smart Keypad app.
Mode 0
When this mode is active, Event Input 1 is disabled.
1251
$
4
$
9
$
0
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 4 and listen for good tone.
Enter secondary sub mode 9 and listen for status tones:
Good tone:
Event Input 1 is disabled (Mode 0).
One tone:
Mode 1 enabled.
Two tones:
Mode 2 enabled.
Three tones: Mode 3 enabled.