1.  DESCRIPTION 

The MXD consists of several components which, when 

combined with a Magnalock

, will 

produce 

an initiate signal for delayed exit

 as controlled by Securitron’s XDT logic timer when 

a person pushes on the door and moves it a modest distance. 

The specific components within the MXD “kit” are: 

mounting sub-plate

 which affixes the magnet body to the door frame or header. 

sealed proximity switch array

 which is also mounted on the sub-plate.  This changes state 

to provide the initiate signal. 

A stamped, 

stainless steel housing

 which covers the magnet body and proximity switch array. 

A sealed 

permanent magnet

 affixed to a bracket that mounts behind the strike plate.  As this 

unit moves away from the proximity array, the array switches. 

A special 

sex bolt with internal spring

 that permits the door to move away from the strike 

plate (the strike plate remains secured to the magnet body) so as to create the initiate signal 
when a person pushes on the door opening it up to one inch. 

Summary of Contents for MXD-62

Page 1: ...it a modest distance The specific components within the MXD kit are A mounting sub plate which affixes the magnet body to the door frame or header A sealed proximity switch array which is also mounte...

Page 2: ...mount the MXD sex bolt when you are using the model 32 lock Some others will accept a model 62 lock but only when you are using the offset strike To determine in advance whether your door and the Mag...

Page 3: ...i rotation pins while including new anti rotation pins For a thicker door the bolt may be partially unscrewed to expand it for use with up to a 2 thick 51MM door If you do this be sure to install Thre...

Page 4: ...his will allow you to get a vise grip onto the female threaded shaft in the MXD sexbolt Turn the strike mounting screw a couple of more turns and then re rotate the strike so that its roll pins again...

Page 5: ...ot mount the cover yet as you will want to check adjustment of the proximity switch array Mounting the cover is the final step when everything else is complete When you do mount the cover the long bin...

Page 6: ...gnet is separated from the switch array the delay initiate signal will be given This provides redundant reliability of safe egress operation as single component failure will not stop the MXD from allo...

Page 7: ...ustomer The replacement at SECURITRON s sole option may be the identical item or a newer unit which serves as a functional replacement In the event that the product type has become obsolete in SECURIT...

Page 8: ...oor Movement Hardware shall be produced by an ISO 9001 certified manufacturer The door movement hardware shall be of a modular nature and not an integral part of the magnetic lock It shall consist of...