background image

T/SED900/026A 
 

22

nd

 August 2018 

Installation Instructions for SBL639/SP  Digital Lock when used with Touch Bar 
Latch. 

The safety features of this product are essential to its compliance with EN1125: 2008 and EN179: 2008. No 
modification of any kind, other that those described in these installation instructions are permitted. 

 

Installation 

 

Correctly position and tape the template (T/SED900/025), to internal face of door, at correct height 
from the floor level. 

 

Check that when the door is closed the edge of the door frame is correctly aligned with the marked 
door edge on template.  

 

Mark the 4 pilot holes to secure the Touch Bar bracket 

 

Mark the two 8mm holes, for bolt through fixings and cup washers to secure Digital Lock 

 

Mark the 19mm diameter hole for the connecting bar of the Digital Lock 

 

If fixing to Rebated Double Doors mark position of holes for Universal Strike on the Inactive Leaf. 

 

Drill all marked holes. 

 

Counter sink the lower 8mm hole by 10mm for brass cup washer 

 

Setting/Changing the Code 

 

On the reverse of the Digital Lock Unit you will see slotted buttons which 
correspond to the push buttons on the front of the Lock. 

 

To set a button to operate within the code turn the slotted button relating to 
the number so that the dot is facing outwards (towards the ‘G’)  

 

To take a button out the code turn the slotted button so the dot is facing 
inward (towards the ‘F’) 

 

Check the code on the Lock functions before fitting to the door. 

              IMPORTANT: Always press the ‘C’ button before inputting the programmed code 

 
Handing the Digital Keypad

 

For Left-handed use 

 
 
 
 
 
 
 

 
 

 
 
Fixing the Lock  

 

Cut the fixing bolts to suit door thickness, for the Digital Mechanical 
Lock, allowing at least 4/5 threads to screw into the lock case 

 

Locate the rubber seal behind the Digital Lock and using the fixing bolts 
and cup washers secure the top and bottom of the Lock to the door. 

 

Before final tightening ensure the lock is vertical and test mechanism 
to ensure that it is moving freely. 

 

For Right-handed use 

 

After removing the Grub Screw; lift 
and rotate the lever handle 180 
degrees anti-clockwise. Relocate 
the grub screw and tighten to 
secure lever handle 

 

Locate the Grub Screw in the 
Lever Handle unscrew and 
remove it using the supplied 
Allen Key.  

 

Locate the Grub Screw in the 
Lever Handle unscrew and 
remove it using the supplied 
Allen Key.  

 

After removing the Grub Screw; lift 
and rotate the lever handle 180 
degrees clockwise. Relocate the 
grub screw and tighten to secure 
lever handle 

 

Distance from floor to be 
between 900mm-1100mm 

 

Reviews: