background image

 

 

SSR 302

 

User and Installation Instructions

 

 
 

 

 
 

Two channel 3 Amp switch (Rx) 

– Z-Wave

 

Summary of Contents for SSR 302

Page 1: ...SSR 302 User and Installation Instructions Two channel 3 Amp switch Rx Z Wave...

Page 2: ...nds This SSR 302 will act as a repeater once added into the Z Wave network providing an alternative communication route for units which otherwise would not be within communication distance of each oth...

Page 3: ...function Both White buttons Network function Solid Amber Unit is added on to a network and a Zone has not timed out to failsafe mode to indicate loss of communication Top White button held for Zone 1...

Page 4: ...White buttons Network function Flashing Amber One of the Zones has entered failsafe mode With Top White button held or Bottom White button held the Red and Green buttons switches relay output off and...

Page 5: ...The backplate should be fitted with the wiring terminals at the top and in a position which allows a total clearance of at least 50mm around the receiver Direct Wall Mounting The receiver should ideal...

Page 6: ...ng can only enter from beneath the receiver and must be securely clamped The mains supply terminals are intended to be connected tothesupply bymeans of fixed wiring The receiver is mains powered and r...

Page 7: ...tions Fitting the Receiver If surface wiring has been used remove the knockout insert from the bottom thermostat to accommodateit Fit the receiver to the backplate ensure the lugs on the backplate eng...

Page 8: ...tsflashinggreen The SSR 302 has been added onto the network and theLEDwill gosolidamber NOTE If the LED does not flash green the add process has beenunsuccessful Removing from a Network To remove from...

Page 9: ...nit supports two static end points for the two channels Pressing the TopWhite button for 1 second will issue an end pointcapabilityreport forZone1 Pressing the Bottom White button for 1 second will is...

Page 10: ...006 SSR 302 Device ID Type 0 and 1 for serial number Data format Binary length 4 Bytes Version V2 Get Report Version Command Class Get Version Command Class Report Provides the version number of the Z...

Page 11: ...des having endpoints Product supports one group Lifeline and has a maximum of 4 nodes Association Group Info V1 Group Name Get Group Name Report Group Info get Group Info Report Group Command List Get...

Page 12: ...command class as follows Basic Set Mapped to Switch Binary Set Basic Get Mapped to Switch Binary Get Basic Report Mapped to Switch Binary Report Same as Switch Binary command class there is no failsa...

Page 13: ...vice comes in factory default state and will not send device reset locally notification This command is used to independently access the two channels available on the SSR 302 Product has 2 identical n...

Page 14: ...t Software class Class A Receiver category Category 3 Power class Class B Mechanical Dimensions 120mm x 90mm x 32mm Case material thermoplastic flame retardant Ball pressure test Temperature 75 C Moun...

Page 15: ...together com European Sales Office CEWE Instrument AB Box 1006 611 31 Nyk ping t 46 8 600 80 60 e info securetogether com www securetogether com www securetogether com Australia Sales Office Secure Au...

Page 16: ...4 2492 300 05 f 91 294 2492 310 e mktg securetogether com www securetogether com Elegant Metering Solutions FZE 4EA 326 P O Box 54857 Dubai Airport Free Zone Dubai UAE p 971 50 6575166 f 971 04 204 56...