Secure SSP 302 User And Installation Instructions Manual Download Page 1

 

SSP 302 

Socket Energy Monitor 

 

User and Installation 

Instructions

 

BGX501-921-01

 

Summary of Contents for SSP 302

Page 1: ...SSP 302 Socket Energy Monitor User and Installation Instructions BGX501 921 01...

Page 2: ...Controller Lamp Load Secure SSP 302 Socket Energy Monitor The Secure SSP 302 forms part of a Z Wave Plus home automation network SSP 302 is a mains powered plug in device that supports energy monitor...

Page 3: ...etwork and helps other device messages to reach a destination SSP 302 is a fully compliant Z Wave Plus device that will work with other manufacturer s Z Wave devices Installation Step 1 Unpack and ins...

Page 4: ...is on Press the top button the relay status LED should switch ON and glow green If the relay status LED does not glow then the device is not functioning It is possible that the SSP 302 was part joined...

Page 5: ...with the low power radio signals between the unit and the controller Step 2 Z Wave Plus commissioning To include the SSP 302 onto a network put the controller into inclusion mode Now press and hold th...

Page 6: ...or controller relevant actions On successful inclusion the LED will turn off The total process can take up to 20 seconds Refer to the Technical specifications Radio section for details If the device f...

Page 7: ...controller into exclusion mode refer to controller instructions and follow the same sequence as per the commissioning process for include node After successful exclusion the network status LED will st...

Page 8: ...02 in a Z Wave Network follow steps 3 to 5 Note Association process works only after device included onto network Step 3 Put the controller into Association Mode Note Some controllers can automaticall...

Page 9: ...second but less than 4 seconds and then release Step 5 The controller will confirm association when the process is successfully completed 9...

Page 10: ...ON power switched to front socket Green LED Socket type will vary with country Appliance Socket Press the SSP 302 button less than one second to supply power to its socket By default the green LED wil...

Page 11: ...ged into the appliance socket Over Current Protection If the current exceeds the limit for more than 30 seconds the load will be disconnected To reconnect the user needs to press the button or send an...

Page 12: ...e that provides the following electrical parameters with an accuracy of 2 or better from 23W to full load and less than 0 5W from 1W to 23W 1 Voltage 2 Current 3 Active power 4 Apparent Power 5 Active...

Page 13: ...the current is less than the standby current for 30 seconds the load will be disconnected to save energy refer to the configuration parameter 16 of Configuration parameters table for how to configure...

Page 14: ...cket outlet Toggles green LED 1 4 seconds Association NA 4 7 seconds Inclusion exclusion Red LED flashes twice per second 7 11 Seconds Resets device data NA 11 15 seconds SSP 302 resets to factory def...

Page 15: ...Device Class Generic Binary Switch Specific Not used Basic Routing Slave Supported Command class Command Class Commands Supported Basic CC V1 Get Set Report Basic CC is mapped to binary switch CC Bina...

Page 16: ...ID 0x0001 UK EU Product ID 0x0002 ANZ Version V2 Get Report Version Command Class Get Version Command Class Report Association V2 Set Get Report Remove Supported Groupings Get Supported Groupings Rep...

Page 17: ...eport Power cycle the device and press and hold the button for more than 11 seconds and less than 15 seconds within the 60 seconds of power cycle to put the device in factory default that include sett...

Page 18: ...ile MSB ASSOCIATION_GROUP_INFO_REPORT_P ROFILE_GENERAL Profile LSB Group1 0x01 Group2 0x02 Group3 0x03 Group4 0x04 Group5 0x05 Supported Command class and command Group 1 to Group3 CC COMMAND_CLASS_ME...

Page 19: ..._ON Node Type ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVE PLUS_NODE Installer Icon ICON_TYPE_GENERIC_ON_OFF_POWER_SWITCH User Icon ICON_TYPE_GENERIC_ON_OFF_POWER_SWITCH Power Level V1 Power Level Set Power...

Page 20: ...ort Meter Reset Meter table Monitor V1 ID Get ID Report Capability Get Capability Report Current Data Get Current Data Report Meter Table Configuration V1 Meter Table Point Adm Number Set Command CRC...

Page 21: ...ne device in the network that has real time clock and supports time command class Once the SSP 302 has received the time it will start logging the historical data The SSP 302 will continue metering ev...

Page 22: ...olution Max Value Default Value Parameters 1 to 7 delta based configuration 1 Switch Status NA 1 NA 1 0 2 Voltage V 2 0 1 60 0 3 Current A 2 0 01 15 0 4 Power Factor 2 0 1 100 0 5 Active Power W 2 1 4...

Page 23: ...ltage Delta 10V 10 0 1 100 e g Current Delta 5A 5 0 01 500 e g Power Factor 10 10 0 1 100 e g Power Energy 100W 100 1 100 Parameters 8 to 14 time interval based configuration 8 Switch Status Sec 2 1 6...

Page 24: ...equal to desired value minus 65536 For example to set time interval to 36000 seconds it may be needed to set a value 36000 65536 29536 Parameters 15 to 16 general configuration 15 Relay and LED config...

Page 25: ...be rejected silently and SSP 302 will retain it last configuration value IMPORTANT when any configuration is set then it shall be recommended that user should read back and verify the correctness of...

Page 26: ...last status over the power cycle ON for Relay Open OFF for Relay Close SSP 302 is shipped with zero default relay LED configuration Visual Indication of a Communication Failure The SSP 302 can indicat...

Page 27: ...ociated device in the network for more than one hour the device will indicate a communication fail status The communication fail status will be represented on the device by the continuous glowing of t...

Page 28: ...ng UK 13 3 A max 3kW EU 16 3 A max 3 6kW ANZ 10 3 A max 2 3kW Control type Micro disconnection Control action Type 1B Software class Class A Burden 1W in standby Mechanical Dimensions WxDxH mm UK 60 x...

Page 29: ...ary check compatibility before use Mounting UK Type G EU Schuko Type E F ANZ Type I Ball Pressure Test Temperature 75 C Environmental Impulse voltage rating Cat II 2500V Storage temperature 20 C to 55...

Page 30: ...the SSP 302 will try with NWI Network Wise Inclusion The total process can take up to 20 seconds This is a Z Wave certified product and can be used with Z Wave controllers that support its functional...

Page 31: ...Compliance HS RO EN 60730 1 RoHS R TTE directive ETSI EN 300 220 2 BS 1363 3 for UK IEC 60884 1 for EU AS NZS 3122 and RCM ACMA for ANZ 31...

Page 32: ...Notes...

Page 33: ...Notes 33...

Page 34: ...South Bristol Business Park Roman Farm Road Bristol BS4 1UP UK e info securetogether com www securetogether com European Sales Office CEWE Instrument AB Box 1006 611 31 Nyk ping t 46 8 600 80 60 e inf...

Page 35: ...airfield VIC 3078 Australia p 61 3 9485 6000 f 61 3 9485 6099 e info securetogether com www securetogether com Secure Meters Ltd Pratapnagar Industrial Area Udaipur 313003 India p 91 294 2492 300 05 f...

Page 36: ...Elegant Metering Solutions FZE 4EA 326 P O Box 54857 Dubai Airport Free Zone Dubai UAE p 971 50 6575166 f 971 04 204 5619 e emsfze emsdxb ae www securetogether com...

Reviews: