7. Others 

7.1 Users Operation 

 

 

 

Open the door: Read valid user card.  

Remove Alarm: Read valid user card or Master card  

7.2 Reset to Factory Default & Add Master Cards 

  

Power off access device, press the Exit Button (see connection diagram), hold it and power on, 

after two beeps, release the Exit button and both green and red LED on with one beep, then read any 

two  13.56MHz  MIFARE  card,  the  LED  will  turn  into  solid  red,  means  reset  to  factory  default 

successfully. Of the two cards reading, the 1

st

 one is Master Add Card, the 2

nd

 one is the Master Delete 

Card.   

 

After  two  Master  Cards  made,  should  use  them  to  add  /  delete  User  cards  to  make  sure 

everything is all right.  

 

  

Remarks:   

 

 

If no Master Cards added, must press the Exit Button for at least 10 seconds before release.  

 

Reset to factory default, the user’s information (cards added before) will still be retained.   

 

Using same ID to assign to cards (Add Card: using User ID), the buzzer will beep 3 times to 

warn you, but if you insist on using the same User ID, reader will allow you to do so. But this is 

a very bad practice that should be avoid, because when times comes that you delete the Card 

by  User  ID,  only  the  first  one  added  will  be  deleted,  others  will  remain  valid  and  cannot  be 

deleted using that User ID. The others with the same User ID can only be deleted using Delete 

Card by Card method afterwards. 

  

 

 S2-MF

 

 Simplified Instruction

 

Function description 

                  

 

Operation 

 

Enter the programming mode  

* (123456) # 
 
then you can do the programming.

 

(123456 is the factory default master code) 

  

Change the master code  

0 (new code) # (repeat the new code) #   

 

(master code: 6 digits) 

 

Add card user  

1 (Read Card) #  
 

(can add Cards continuously) 

Delete card user  

2 (Read Card) #  

 

(can delete Cards continuously) 

Summary of Contents for B064-Y69

Page 1: ...B064 Y69 S2 MF Access Control Single Door Standalone Card Reader User Manual Ver 1 0...

Page 2: ...M 4 5 MASTER CARDS USAGE 5 6 PROGRAMMING 6 6 1 BASIC CONFIGURATION 6 6 1 1 Enter and Exit Program mode 6 6 1 2 Set Master Code 6 6 2 ADD USER CARDS 6 6 3 DELETE USERS 7 6 4 SET RELAY CONFIGURATION 7 6...

Page 3: ...ration Pulse mode Latch mode Remote infrared programmer 1000 users Two color LED status display Built in light dependent resistor LDR for anti tamper Buzzer for audible or silent mode Low temperature...

Page 4: ...e hole for the cable Knock the supplied rubber bungs to the screw holes A C Fix the back cover firmly on the wall with 4 flat head screws Thread the cable through the cable hole B Attach the unit to t...

Page 5: ...en NC Normally closed Relay Output Yellow OPEN Request to Exit input REX 3 2 Sound and LED Status Indicators Operation Status LED Buzzer Stand by Solid Red Enter into programming mode Pulsing Red One...

Page 6: ...4 4 Connection Diagram Common power supply Attention Install a 1N4004 or equivalent diode is needed when use a common power supply or the reader might be damaged 1N4004 is included in the packing...

Page 7: ...Usage Using Master Cards is the easiest way to add or delete cards Add Card User 1 Read Master Add Card 2 Read User Card Repeat Step 2 for additional user cards 3 Read Master Add Card to stop adding N...

Page 8: ...ack it The user ID number can be any number from 1 1000 IMPORTANT User IDs do not have to be proceeded with any leading zeros Recording of User ID is crical Modifications to the user require the User...

Page 9: ...Exit 6 3 Delete Users Programming Steps Keystroke Combination 1 Enter Program Mode Master Code Delete Card 2 Delete Card By Card OR 2 Delete Card By User ID if two cards have the same User ID the fir...

Page 10: ...for 10 minutes after engaging or disengage only after entering a valid card or Master code Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Strike Out OFF OR 2 Strike Out ON s...

Page 11: ...release Reset to factory default the user s information cards added before will still be retained Using same ID to assign to cards Add Card using User ID the buzzer will beep 3 times to warn you but i...

Page 12: ...d using User ID at front door reader and add a different back door card using same User ID at back door reader since the two different cards use the same User ID can they use to open both front and ba...

Reviews: