9
7. Others
7.1 Users Operation
Open the door: Read valid user card.
Remove Alarm: Read valid user card or Master card
7.2 Reset to Factory Default & Add Master Cards
Power off access device, press the Exit Button (see connection diagram), hold it and power on,
after two beeps, release the Exit button and both green and red LED on with one beep, then read any
two 13.56MHz MIFARE card, the LED will turn into solid red, means reset to factory default
successfully. Of the two cards reading, the 1
st
one is Master Add Card, the 2
nd
one is the Master Delete
Card.
After two Master Cards made, should use them to add / delete User cards to make sure
everything is all right.
Remarks:
①
If no Master Cards added, must press the Exit Button for at least 10 seconds before release.
②
Reset to factory default, the user’s information (cards added before) will still be retained.
③
Using same ID to assign to cards (Add Card: using User ID), the buzzer will beep 3 times to
warn you, but if you insist on using the same User ID, reader will allow you to do so. But this is
a very bad practice that should be avoid, because when times comes that you delete the Card
by User ID, only the first one added will be deleted, others will remain valid and cannot be
deleted using that User ID. The others with the same User ID can only be deleted using Delete
Card by Card method afterwards.
S2-MF
Simplified Instruction
Function description
Operation
Enter the programming mode
* (123456) #
then you can do the programming.
(123456 is the factory default master code)
Change the master code
0 (new code) # (repeat the new code) #
(master code: 6 digits)
Add card user
1 (Read Card) #
(can add Cards continuously)
Delete card user
2 (Read Card) #