background image

ENFORCER

®

Installation Manual

SA-026

Mini Timer Module

The ENFORCER SA-026 is a low-voltage miniature
timer module which operates on 12~24V AC or DC.
It can be used to modify the activation time of a
momentary contact switch for 1~60 sec. via a field-
adjustable VR (variable resistor) rotary knob. It is
ideal for electrical or electromagnetic locks which do
not have a built-in time delay function.

Features

• Compact size: 1

3

/

16

”x2

9

/

32

”x

5

/

8

” (30x58x16 mm).

• Operating voltage: 12~24 volts AC or DC.
• Relay output: Form-C (SPDT), via terminal block.
• Contact rating: 3 Amps @ 24VDC.
• Built-in buzzer output: (100mA @ 24VDC).
• Includes double-sided foam tape.

Sample Application: 

Fail-Safe Electromagnetic Locks

L

C -

SECO-LARM

®

 

 

 

 

 

 I

 

., 

 U.S.A., Inc.

16842 Millikan Avenue, Irvine, CA  92606

Tel: 800-662-0800 / 949-261-2999   Fax: 949-261-7326

WARRANTY:

 

This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of one (1)

year from the date of sale to the original consumer customer.  SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is

returned, transportation prepaid, to SECO-LARM.

This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or

abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes

other than defects in material and workmanship.

The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option.   In no event

shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.

NOTICE:

  

The information and specifications printed in this manual are current at the time of publication.  However, the SECO-LARM policy is one

of continual development and improvement.  For this reason, SECO-LARM reserves the right to change specifications without notice.  SECO-LARM is

also not responsible for misprints or typographical errors.

Copyright © 2006 SECO-LARM U.S.A., Inc.  All rights reserved.  This material may not be reproduced or copied, in whole or in part, without the written
permission of SECO-LARM.

PITSW1

Website: www.seco-larm.com

E-mail: [email protected]

Also available:

Push-to-Exit plates with built-in timers.

SD-7201GA-PT1

SD-7202GC-PT

FILE: DT/DTP/MiSA026_06A.pmd

ORDER PART# 763-153%

SA-026

Trigger Devices:

Push-to-exit

switches,

keypads, control

panels, etc.

Power (non polarity)

12~24 volts DC

Power Supply

+     -

Electrical exit

locking devices

such as magnetic locks or

electric strikes.

Beeper

Power (non polarity)

TRG. (COM)

TRG. (N.C.)

TRG. (N.O.)

-  +

To N.O. switch

To N.C. switch

Relay O/P (N.C.)

Relay O/P (N.O.)

Relay O/P (COM)

Buzzer O/P (-)

Buzzer O/P (+)

To N.O. device

To N.C. device

Time adjustment

(1~60 sec.)

VR rotary knob,

clockwise to

increase, and

counterclockwise

to decrease.

NOTE: Terminal legend can be found on back of the PCB.

Reviews: