background image

 

10 

 

9.  What to do if alarms were triggered 

1.  Immediately ensure for fresh air supply by opening doors and windows! 

2.  Press the TEST/SILENCE button, to mute the alarm tone. This prevents panic! 

3.  If possible, turn off all combustion devices and gas supplies! 

4.  Call the emergency-call when people complain about symptoms of poisoning, e.g. headaches 

or nausea (

see chapter 1

)! 

5.  Pay attention to all the people in the room and allow the immediate leaving the room. Make 

sure that nobody remains behind! Also make sure that no one can return or move away from 
the open door or open windows until the rescue forces have arrived. The alarm must not be 
deactivated during this time! 

6.  Do not restart the switched-off combustion device until it has been checked by an expert! 

7.  Check each combustion device! If no specialist or verification device is available, follow the 

manufacturer’s instruction and refer directly to the manufacturer of the defective device. 

Note:

 Even if the CO alarm detective does not indicate any danger after venting, it is advisable to 

determine the cause of the alarm or the source of the carbon monoxide! There is danger to life! 

 

 

 

 

 

 

 

 

 

 

 

the sudden loud alarm sound 

Function-Test 

To test the alarm, press the TEST/SILECNE button. The test 
alarm ends by releasing the TEST/SILENCE button.  

Note: 

Test the device weekly! If the test alarm is not executed as 

described, replace the CO alarm detector immediately! 

Summary of Contents for GS810

Page 1: ...r should be installed 4 4 Product Overview 6 5 Installation 6 6 Startup 7 6 1 Activation of the CO alarm detector 7 6 2 Checking the function of the CO alarm detector 8 6 3 Recurring self test of the...

Page 2: ...alarm sounds This CO alarm detector may only be used in private rooms The CO alarm detector must be activated before use see chapter 6 1 After a maximum of 10 years as well as with signaling the batt...

Page 3: ...e following symptoms appear by a carbon monoxide poisoning The symptoms of carbon monoxide poisoning are similar to influenza but without fever Other symptoms are dizziness tiredness weakness headache...

Page 4: ...ple using a screwdriver pliers hammer etc Do not drop the device because this can damage it The conversion of this product is not allowed Any other use than the description may result in damage to the...

Page 5: ...entilators Do not install near ventilation systems chimneys or exhaust pipes as well as doors and windows as this may have a lower carbon monoxide concentration Keep the CO alarm detector away from st...

Page 6: ...mute 4 FAULT Error display yellow LED 5 POWER Control light green LED 5 Installation Before starting up this product please check for external damage In case of visible external damage we immediately...

Page 7: ...e screw until the screw head protrudes about ca 55mm from the wall 3 The mounting hole for the screw is located on the rear of the housing Insert the screw head into the mounting hole and press the CO...

Page 8: ...urring self test of the CO alarm detector When operating properly the green LED POWER flashes every 30 seconds Note If the CO alarm detector is not working properly contact the manufacturer 7 Explanat...

Page 9: ...flash every 30 seconds Warning of the end of life If the device beeps three times every 30 seconds and the yellow LED FAULT flashes the end of life of the device is reached CO alarm warning At a dange...

Page 10: ...have arrived The alarm must not be deactivated during this time 6 Do not restart the switched off combustion device until it has been checked by an expert 7 Check each combustion device If no special...

Page 11: ...chapter Installation The battery will last approximately 10 years during normal operation If the unit beeps twice every 30 seconds and the yellow LED FAULT flashes the battery is empty and the CO alar...

Page 12: ...free from contamination at all times in order to ensure proper functioning Note Never open the housing to clean the unit from the inside This can impair the functionality and the warranty guarantee wi...

Page 13: ...e harmful Substances which are contained in the batteries may cause danger to health and the environment in case of improper disposing 14 General Disposal This product may not be disposed of with hous...

Reviews: