2.3 MFR6
1.
Datacable Connector
To insert and retrieve NMEA data, you need to connect the data cable here.
Pin
Color
Baudrate
Description
1
Brown
4.800
NMEA Input +
2
Red
4.800
NMEA Input +
3
Orange
4.800
NMEA Input +
4
Yellow
4.800
NMEA Input +
5
Green
-
NMEA Input - (Ground)
6
Blue
38.400
NMEA
7
Purple
38.400
AIS NMEA Input +
8
White
-
NMEA Output - (Ground)
2.
Power Connector
You can connect the supplied 2-Pin powercable which includes a build-in 0.5A, here.
Pin
Color
Description
1
Black
- 12 / 24 Volt DC
2
White
+ 12 / 24 Volt DC
4.
Electrical grounding
To avoid mutual interference, the unit must be grounded.
3. Thumbscrews
The two included thumbscrews are used to secure the device with the mounting
bracket. This allows also an “upside down” mounting.
7
1
2
3
4
Summary of Contents for AIS6
Page 1: ...User Manual AIS6 MFR6...