background image

1.1.

ELECTRICAL SAFETY

!

WARNING! It is the owner’s responsibility to read, understand and comply with the following:

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and all electrical
connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety devices. An RCCB (Residual
Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD
(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD together with portable products that are plugged into an
electrical supply not protected by an RCCB. If in doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.

You must

also read and understand the following instructions concerning electrical safety.

1.1.1.

The Electricity At Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified electrician, using a 
Portable Appliance Tester (PAT), at least once a year.

1.1.2.

The 

Health & Safety at Work Act 1974

makes owners of electrical appliances responsible for the safe condition of the appliance and the safety of the 

appliance operator. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.

Ensure the insulation on all cables and the product itself is safe before connecting  to the mains power supply. The pump and cable are designed for 
submerging in water and as such must not be tampered with (if in doubt, contact a qualified electrician).

1.1.4.

Ensure that cables are always protected against short circuit and overload.

1.1.5.

Regularly inspect power supply leads, plugs and all electrical connections for wear and damage, especially power 
connections, to ensure that none is loose. 

1.1.6.

Important:

Ensure the voltage marked on the product is the same as the electrical power supply to be used, and check

that plugs are fitted with the correct capacity fuse. A 13 amp plug may require a fuse smaller than 13 amps for certain 
products, see fuse rating at right. 

1.1.7.

DO NOT pull or carry the appliance by its power supply lead. 

1.1.8.

DO NOT pull power plugs from sockets by the power cable.

1.1.9.

DO NOT use worn or damaged leads, plugs or connections. Immediately replace or have repaired by a qualified electrician. 
A U.K. 3 pin plug with ASTA/BS approval is fitted. In case of damage, cut off and fit a new plug according to the 
following instructions (discard old plug safely).
(UK only - see diagram at right). 

Ensure the unit is correctly earthed via a three-pin plug. 

a)  Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to live terminal ‘L’.
c)  Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation extends beyond 
the cable restraint and that the restraint is tight.

1.1.10. The electrical cable is designed for use in water and must not be substituted. If damaged contact a qualified electrician.
1.1.11.

Extension cable use. Only use a cable designed for use with water equipment. Contact your dealer or a qualified electrician for advice. 
Ensure water is kept clear of electrical mains power supply. DO NOT touch switch or plug with wet hands.

INSTRUCTIONS FOR:

SUBMERSIBLE POND PUMP

WPP1100

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.

1.

SAFETY INSTRUCTIONS

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

Blue
Neutral 
Wire

Yellow & Green 
Earth Wire 

Cable
Restraint

FUSE RATING

5 AMP

Brown
Live 
Wire

1.2

GENERAL SAFETY

!

WARNING! 

This pump must be used in accordance with Health & Safety, government, local authority and water authority rules and

regulations including appropriate procedures for the protection of persons, animals, equipment and property.

#

Familiarise yourself with application, limitations and potential hazards peculiar to the pump.

!

WARNING!

Disconnect the pump from the mains power before changing accessories, servicing or performing any maintenance.

!

WARNING!

DO NOT have contact with the water whilst the submerged pump is connected to the mains supply.

#

Maintain the pump in good condition (use an authorised service agent). Keep the pump clean.

#

Replace or repair damaged parts. 

Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

#

Switch off the power on all devices that are in contact with the water before carrying out any cleaning or maintenance work on the device.

$

DO NOT operate the pump if any parts are damaged or missing as this may cause failure and/or personal injury.

$

DO NOT use the pump for any purpose other than for which it is designed.

$

DO NOT operate the pump out of water. The pump pick-up area must be completely submerged during operation.

$

DO NOT operate the pump during freezing temperatures. DO NOT leave the pump in water that may freeze.

$

DO NOT carry the pump by its electrical cable, or outlet pipe. 

$

DO NOT use the device in water additionally chlorinated or in acidic or alkaline solutions.

$

DO NOT use in salt water.

$

DO NOT let the pump run dry. This can cause irreparable damage.

WPP1100 - 2 - 120906

2.

INTRODUCTION & SPECIFICATION

A pond pump suitable for creating garden water fountain features. It also provides the
important functions of filtration and water circulation which are necessary to maintain healthy
plant and fish life. WPP1100 comes with two fountain heads Cascade and Water Bell. 
The pumps compact design makes it very powerful yet at the same time energy efficient. 
A magnetic impeller is driven by a leak proof synchronous motor.

Technical Data.

Model No:

WPP1100

Power Consumption:

230V 20W

Max. Head:

1.1mtr

Max. Flow Rate:

1100ltr/hr

Max. Submersion Depth:

3mtr

Power Cable:

10mtr

Max. Temp. of the Pumped Fluid:

35°C

Protection Type:

IP68

Water Bell

Cascade fountain

Outlet pipe

Pump

Rubber feet

Reviews: