Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and 

properly maintained, give you years of trouble free performance.

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. 

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE 

DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1.2. 

  GENERAL SAFETY

 

WARNING! 

Pump must be used in accordance with Health & Safety, government, local authority, and water authority rules and regulations.

  Familiarise yourself with application and limitations, as well as the specific potential hazards peculiar to the pump.

 

WARNING!

 

Disconnect the

 

pump from the mains power before changing accessories, servicing or performing any maintenance.

  Maintain the

 

pump in good condition (use an authorised service agent). Keep the pump clean.

  Replace or repair damaged parts. 

Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

  Only use for pumping clean cold or warm water (

NOT

 exceeding 35ºC). .

  If the bottom of the water container is covered with sludge, sand, gravel or mud etc, suspend the pump or place it on a raised base to 

  operate above the solid matter. Sand and such substances will reduce working life of pump, and invalidate your warranty..

 

DO NOT

 operate the pump if any parts are damaged or missing as this may cause failure and/or possible personal injury.

 

DO NOT

 use the pump for any purpose other than that for which it is designed.

 

DO NOT

 use to pump chemicals, fuels or salt water.

 

DO NOT

 insert hands into the mouth of the pump as this could lead to injury.

 

DO NOT

 use to pump septic tanks or settling pits. 

DO NOT

 pump any liquids other than water.

 

DO NOT

 operate the pump out of water. The pump pick up area must be completely submerged during operation.

 

DO NOT

 exceed the maximum submersible depth (see specifications: Max. Water Depth). 

 

DO NOT

 operate the pump during freezing temperatures. 

DO NOT

 leave the pump in water that may freeze.

 

DO NOT

 use for pumping sea water or inflammable, corrosive, explosive or dangerous liquids. 

 

DO NOT

 carry the pump by its electrical cable, or its outlet pipe. Use the handle only. 

  When not in use, switch off pump and remove plug from power supply. Rinse pump, drain out any water and store in a frost free, safe location.

 

WARNING! DO NOT allow uncontrolled discharge of contaminated water which would pollute the environment.

1.1. 

ELECTRICAL SAFETY 

 

WARNING! It is the owner’s responsibility to read, understand and comply with the following:

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and 

all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety 

devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD

(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD together with portable products that are 

plugged into an electrical supply not protected by an RCCB. If in doubt consult a qualified electrician. You may obtain a Residual Current 

Device by contacting your Sealey dealer. 

You must

 also read and understand the following instructions concerning electrical safety.

1.1.1.  The Electricity At Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified    

 

electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2. The 

Health & Safety at Work Act 1974

 makes owners of electrical appliances responsible for the safe condition of the appliance    

 

and the safety of the appliance operator. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure the insulation on all cables and the product itself is safe before connecting  to the mains power supply. The pump and cable    

 

are designed for submerging in water and as such must not be tampered with (if in doubt, contact a qualified electrician).

1.1.4.  Ensure that cables are always protected against short circuit and overload.

1.1.5.  Regularly inspect power supply leads, plugs and all electrical connections for wear and damage,    

 

especially power connections, to ensure that none is loose. 

1.1.6. 

Important: 

Ensure the voltage marked on the product is the same as the electrical power supply to be  

 

used, and check that plugs are fitted with the correct capacity fuse. A 13 amp plug may require a fuse  

 

smaller than 13 amps for certain products, see fuse rating at right. 

1.1.7. 

DO NOT

 pull or carry the appliance by its power supply lead. 

1.1.8. 

DO NOT

 pull power plugs from sockets by the power cable.

1.1.9. 

DO NOT

 use worn or damaged leads, plugs or connections. Immediately replace or have repaired  

 

by a qualified electrician. A U.K. 3 pin plug with ASTA/BS approval is fitted. In case of damage, cut  

 

off and fit a new plug according to the following instructions (discard old plug safely).

 

(UK only - see diagram at right). 

Ensure the unit is correctly earthed via a three-pin plug. 

 

a)   Connect the GREEN/YEllOW earth wire to the earth terminal ‘E’.

 

b)  Connect the bROWN live wire to live terminal ‘l’.

 

c)   Connect the bluE neutral wire to the neutral terminal ‘N’.

 

d)  After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer  

 

 

 

insulation extends beyond the cable restraint and that the restraint is tight.

1.1.10.  Only allow the minimal amount of pump cable to enter water or wet areas. The electrical cable is designed for use in water and must

 

not be substituted. If damaged contact a qualified electrician.

1.1.11. 

Extension cable use. Only use a cable designed for use with water equipment. Contact your dealer or a qualified electrician 

 

for advice. Ensure water is kept clear of electrical mains power supply. DO NOT touch switch or plug with wet hands.

1.  SAFETY INSTRUCTIONS

RECOMMENDED FUSE 

RATING: 5A

Original Language Version

WPB50A   Issue: 1 - 20/11/13

 © Jack Sealey Limited

INSTRUCTIONS FOR:

SUBMERSIBLE WATER BUTT PUMP

50ltr/min 230V

MODEL No: 

WPB50A