background image

7

 

DO NOT

 use the bore scope if dropped and/or damaged.

7

 

DO NOT

 operate near live electrical wires.

7

 

DO NOT

 operate near moving parts such as pulleys, motors, gears or fans etc.

7  

DO NOT

 bend the bore scope shaft tighter than

 

7cm radius (14cm diameter).

7  

DO NOT

 expose the bore scope housing to water or other liquids.

DO NOT

 insert the bore scope shaft into locations whose temperature is greater than 113F° (45C°).

 

Maintain the bore scope in good and clean condition for best and safest performance.

 

A full range of personal safety equipment is available from your Sealey dealer.

 

Wear suitable clothing to avoid snagging. Do not wear jewellery and tie back long hair.

 

Account for all tools and parts being used and do not leave any in, or near, the engine.

 

Be alert to your surrounding environment while using the bore scope. 

Note the location of the object to be inspected and determine a route to it. Bend the bore scope shaft to follow 

the route.

Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

  

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL 

REQUIREMENTS, WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE 

PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL 

INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

  1.  SAFETY INSTRUCTIONS

INSTRUCTIONS FOR:

VIDEO BORE SCOPE COMPACT 

Ø6mm - 1000mm

MODEL No: 

VS8193 

  2.  INTRODUCTION

Compact and versatile unit with colour video camera on a flexible Ø6 x 1000mm probe and 89mm LCD screen. 

Suitable for viewing internal inspection of cylinder head bores, engine compartments and other 

machinery/industrial applications. Features three tip mounted mirrors, 30º, 45º and 60º allowing a clear view in 

confined spaces and a magnet attachment. Fitted with AV-out port and supplied with AV cable. 

Supplied with comprehensive instructions in carry-case.

  3.  SPECIFICATION

Shaft Length . . . . . . . . . . . . . . . . . . . .1000mm

Probe Diameter  . . . . . . . . . . . . . . . . .6mm

Viewing Angle. . . . . . . . . . . . . . . . . . .67°

Viewing Distance . . . . . . . . . . . . . . . .15 - 100mm

Resolution. . . . . . . . . . . . . . . . . . . . . .320 x 240 pixels

Screen  . . . . . . . . . . . . . . . . . . . . . . . .89mm LCD Colour

Batteries . . . . . . . . . . . . . . . . . . . . . . .4 x AA (Supplied)

  4.  OPERATING INSTRUCTIONS

DO NOT

 use excessive force to insert or retrieve shaft from the equipment or areas under inspection.

7

 

DO NOT

 use the tip to push against objects or to clear a path. This instrument is for remote viewing only.

7

 

DO NOT

 bend any part of the shaft tighter than a 2.5 inch radius (5 inch diameter).

7

 

DO NOT

 insert the scope shaft and tip into locations where the temperature is greater than 113F° (45C°).

7

 

DO NOT

 vibrate, bang, or drop your scope. It is not shock resistant.

Fig.1

Original Language Version

VS8193           Issue: 1 - 05/01/10