 IMPORTANT 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS,  

 

AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE, FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO  

 

DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and 

properly maintained, give you years of trouble free performance.

  

WARNING! Ensure Health and Safety, local authority and general workshop practice  

 

regulations are adhered to when using tools and equipment.

 

DO NOT

 use gauge if damaged.

  Maintain gauge in good and clean condition for best performance.

  Keep the work area clean, uncluttered and ensure there is adequate lighting. 

  Keep children and unauthorised persons away from the work area.

 

DO NOT

 use the gauge for any purpose other than for which it is designed.

 

DO NOT

 get gauge wet or use in damp or wet locations, or areas where there is 

 

condensation. Keep gauge clean and dry using a dry cotton cloth only.

 

DO NOT

 dip or submerge the gauge in any type of liquid.

 

DO NOT

 expose gauge to bright sunlight or dust.

 

DO NOT

 disassemble gauge. The gauge must be checked by qualified service personnel only.

 

DO NOT

 apply any voltage to the gauge i.e. with an electric marker pen.

  The gauge is a precision instrument, treat with care, avoid using force and do not subject to 

 

knocks or shocks.

  Use gauge in reasonably constant temperature conditions of approximately 20°C.

  When not in use, turn off and store gauge in a safe, dry, childproof location.

  1. 

SAFETY INSTRUCTIONS.

 2. INTRODUCTION & SPECIFICATION.

Model No:

  . . . . . . . . . . . . .

VS0567

Range:  . . . . . . . . . 0-300mm (0-12") 

Resolution: . . . . . .0.01mm(0.0005") 

Accuracy:  . . . . . ±0.02mm (±0.001") 

Battery Type:  . . . . . . . .SR44 - 1.5V

VS0567    ISSUE No:1  27/03/13

INSTRUCTIoNS foR:

DIGITAL BRAKE DISC AND

DRUM CALLIPER 300MM/12"

MoDEL No: 

 VS0567

  

  Original Language Version

 

© Jack Sealey Limited

KEY

1:. . . . . . . . . . . . . . . . .Internal Jaws

2:. . . . . . . . . . . . . . . . External Jaws

3:. . . . . . . . . . . . . . . . on/off Button

4:. . . . . . . . . . . . . . . . . . Zero Button

5:. . . . . . . . . . . . . . . . . . Hold Button

6:. . . . . . . . . . . Unit Selector Button

7:. . . . . . . . . . . . . . . . . . Lock Screw

8:. . . . . . . . . . . . . . . . Battery Cover

Measures disc thickness (external) and small/medium 

sized drums (internal). Hardened and tempered stainless 

steel gauge. 11mm High figures in LCD display for ease 

of reading. Metric or Imperial read-out with ‘Hold’ function. 

Zero setting control allows for comparative measurement. 

Supplied with calibration certificate and storage case.

fig.1

VS0567

Reviews: