 Original Language Version

6.6. 

CLEANING THE AIR/OIL RADIATOR.

6.6.1. 

remove upper and lower plastic shrouds to gain access to  

 

inside the compressor.

6.6.2. 

Blow compressed air through the radiator, from inside 

 

outwards,making sure that no dirt settles inside the

 

compressor. (fig.12.)

PROBLEM

POSSIBLE CAUSE

SOLUTION

compressor not starting.

no mains power.

check mains power, including

supply fuses and breakers.

compressor stops,

thermal trip activated.

Excessive air/oil mixture

temperature.

check oil level

check that air/oil radiator is not 

blocked.

compressor stops.

motor overheating: motor thermal 

relay activated.

check that power supply is correct.

check for loose cable 

connections and hot cables

check that motor cooling intake is 

not blocked or obstructed.

to resart the compressor: 

allow to cool for a few minutes and 

press the on/off switch.

7. TROUBLESHOOTING

   To reset oil temperature trip: unscrew cap.

Then use pointed object to press trip button,

replace cap.

ssc11003   Issue: 1 - 03/05/13

© Jack sealey Limited

fig.12

fig.13

fig.14

Summary of Contents for SSC11003

Page 1: ... electrical equipment and appliances to ensure they are safe before using You must inspect power supply leads plugs and all electrical connections for wear and damage You must ensure the risk of electric shock is minimised by the installation of appropriate safety devices An RCCB Residual Current Circuit Breaker should be incorporated in the main distribution board You must also read and understan...

Page 2: ... NOT operate the compressor without an inlet air filter 1 5 safety training good practice 7 DO NOT allow anyone to operate the compressor unless they have received full instructions and adequate training 3 KEEP THESE USE AND MAINTENANCE INSTRUCTIONS for future reference and make them available to the compressor operator The operator must be familiar with all the controls and compressor characteris...

Page 3: ... any way Contact your local Sealey dealer for all repairs required Any unauthorised modification may impair the efficiency of the compressor and may also cause serious accidents for those who do not have the technical skill required to make such modifications 3 WE RESERVE THE RIGHT TO MAKE MODIFICATIONS WHERE NECESSARY WITHOUT NOTICE Original Language Version Compact high performance screw compres...

Page 4: ...ld not be modified in any way Original Language Version 4 5 Connecting to the tank compressed air outlet Connect the compressor to the air delivery system using the quick coupler fig3 A Use hose of the same diameter or greater as the compressor outlet If a connection hose leaks or is faulty never try to repair it but replace with a sound one fig 3 fig 3 5 Operation WARNING Ensure that you have rea...

Page 5: ...meters and recommendation stated in these instructions You are advised to keep a record of all maintenance jobs performed on the compressor 6 1 DRAINING CONDENSATE Drain the condensate from the air tank at least once a week by opening the draining valve under the tank fig 4 6 2 OIL CHANGE 6 2 1 Change the oil following the initial 500 hours of use and then every 2500 hours and in any event once a ...

Page 6: ...lter cartridge fig 9 1 using a strap wrench and replace with a new one 6 3 4 Lubricate the sealing gasket before screwing the filter cartridge tight 6 3 5 Tighten the new filter cartridge manually 6 4 replacing the oil separator filter cartridge 6 4 1 Replace the oil separator filter cartridge after the first 500 hours of use then every 2500 hours and in any event each time the oil is changed 6 4 ...

Page 7: ...sor stops thermal trip activated Excessive air oil mixture temperature Check oil level Check that air oil radiator is not blocked Compressor stops Motor overheating motor thermal relay activated Check that power supply is correct Check for loose cable connections and hot cables Check that motor cooling intake is not blocked or obstructed To resart the compressor allow to cool for a few minutes and...

Page 8: ... will clog the pump intake filter and may cause internal damage to pump motor components Please note that any parts damaged by any type of contamination will not be covered by warranty Original Language Version Parts support is available for this product To obtain a parts listing and or diagram please log on to www sealey co uk email sales sealey co uk or phone 01284 757500 Environmental Protectio...

Page 9: ......

Reviews: