1. SAFETY INSTRUCTIONS

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.

USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE

DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1.2.

GENERAL SAFETY

p

WARNING!

Disconnect the saw from the mains power before changing saw blades and accessories, servicing or performing maintenance.

3

Mount the saw to a secure surface such as the stand supplied or a workbench. Keep area clean and tidy and free from unrelated materials

and ensure there is adequate lighting.

3

Maintain the saw in good condition (use authorised service agent only).

3

Replace or repair damaged parts. 

Use recommended parts only. Unauthorised parts may be

dangerous and will invalidate the warranty.

3

Keep the machine clean and the blade sharp for best and safest performance. Check moving parts 

alignment regularly. 

3

Before each use check saw blade condition. If worn or damaged replace immediately.

3

Place the blade guard to within 1/8" of the material being cut.

p

WARNING!

Keep all safety guards and holding screws in place, tight and in good working order. 

Check regularly for damaged parts. A guard or any other part that is damaged should be repaired or 

replaced before the saw is next used. The safety guard is a mandatory fitting.

3

Remove adjusting keys and wrenches from the saw before turning it on.

3

Wear approved safety eye protection, ear defenders, safety gloves and, if dust is generated, 

respiratory protection.

3

Remove ill fitting clothing. Remove ties, watches, rings, and other loose jewellery, and contain long hair.

3

Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.

3

Keep children and unauthorised persons away from the working area.

3

Secure unstable work piece with a clamp, vice or other adequate holding device. 

3

Avoid unintentional starting.

3

Keep hands and fingers at a safe distance from the saw blade, especially at the end of a cut. 

Guide the work with a piece of wood or push rod rather than your fingers when cutting small pieces.

SM64.V2 - 1 - 200902

1.1.

ELECTRICAL SAFETY. 

p

p

 

 

WARNING! It is the user’s responsibility to read, understand and comply with the following:

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and

all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety

devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD

(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD with portable products that are plugged

into an electrical supply not protected by an RCCB. If in doubt consult a qualified electrician. You may obtain a Residual Current Device by

contacting your Sealey dealer. 

You must

also read and understand the following instructions concerning electrical safety.

1.1.1. The 

Electricity At Work Act 1989

requires all portable electrical appliances, if used on business premises, to be tested by 

a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2. The 

Health & Safety at Work Act 1974

makes owners of electrical appliances responsible for the safe condition of the appliance

and the safety of the appliance operator. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3. Ensure the insulation on all cables and the product itself is safe before connecting to the mains power 

supply. See 1.1.1. & 1.1.2. above and use a Portable Appliance Tester (PAT).

1.1.4. Ensure that cables are always protected against short circuit and overload.

1.1.5. Regularly inspect power supply, leads, plugs for wear and damage and all electrical connections

to ensure that none is loose. 

1.1.6.

Important:

Ensure the voltage marked on the product is the same as the electrical power supply

to be used and check that plugs are fitted with the correct capacity fuse. A 13 amp plug may require

a fuse smaller than 13 amps for certain products

,

see fuse rating at right. 

1.1.7.

DO NOT

pull or carry the powered appliance by its power supply lead.

1.1.8.

DO NOT

pull power plugs from sockets by the power cable.

1.1.9.

DO NOT

use worn or damaged leads, plugs or connections. Immediately replace or have repaired by 

a qualified electrician. A U.K. 3 pin plug with ASTA/BS approval is fitted. In case of damage, cut off

and fit a new plug according to the following instructions (discard old plug safely).

(UK only - see diagram at right). 

Ensure the unit is correctly earthed via a three-pin plug. 

a)  Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

b) Connect the BROWN live wire to live terminal ‘L’.

c)  Connect the BLUE neutral wire to the neutral terminal ‘N’.

b) After wiring, check that there are no bare wires, that all wires have been correctly connected, that cable outer

insulation extends beyond the cable restraint and that the restraint is tight.

Double insulated products are fitted with live (BROWN) and neutral (BLUE) wires only. Double insulated products are always marked with

this symbol       .

To re-wire, connect the brown & blue wires as indicated above. DO NOT 

connect the brown or blue to the earth terminal.

1.1.10. Some products require more than a 13 amp electrical supply. In such a case, 

NO

plug will be fitted. 

You must

contact a qualified electrician 

to ensure a 30 amp fused supply is available. We recommend you discuss the installation of a industrial round pin plug and socket with your electrician. 

1.1.11.

Cable extension reels

. When a cable extension reel is used it should be fully unwound before connection. A cable reel with an RCD

fitted is recommended since any product which is plugged into the cable reel will be protected. The section of the cores of the cable

is important. We suggest 1.5mm

2

section as a minimum but to be absolutely sure that the capacity of the cable reel is 

suitable for this product and for others that may be used in the other output sockets, we recommend the use of 2.5mm

2

section cable.

Blue

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

FUSE RATING

THIS PRODUCT MUST BE FITTED 

WITH A 

13 AMP FUSE

Brown

Live 

Wire

Summary of Contents for SM64.V2

Page 1: ...nsult a qualified electrician You may obtain a Residual Current Device by contacting your Sealey dealer You must also read and understand the following instructions concerning electrical safety 1 1 1 The Electricity At Work Act 1989 requires all portable electrical appliances if used on business premises to be tested by a qualified electrician using a Portable Appliance Tester PAT at least once a ...

Page 2: ...ierced to suit and therefore the saw will only fit the stand in one position 1 2 GENERAL SAFETY Continued 3 Disconnect the saw from the power supply before removing wood chips or dust 3 Use a workpiece support when sawing material which extends beyond the saw table 7 DO NOT operate the machine if damaged 7 DO NOT operate the machine if any parts are missing as this may cause failure and or persona...

Page 3: ...e 4 6 2 To adjust belt tension turn tension handle fig 3 L 4 7 Blade speed 4 7 1 Open lower blade cover and remove all belt tension by turning tension knob fig 3 L 4 7 2 Move belt to the required pair of pulleys See fig 6 4 7 3 Tension belt see 4 6 and close cover 4 8 Mitre gauge 4 8 1 The mitre gauge fig 3 K which locates in either of the two table slots is adjustable through 60O in either direct...

Page 4: ...ndsaw Model SM64 V2 73 23 EEC Low Voltage Directive 98 37 EC Machinery Directive 89 336 EEC EMC Directive 93 68 EEC CE Marking Directive The construction file for this product is held by the manufacturer and may be inspected by a national authority upon request to Jack Sealey Ltd Signed by Mark Sweetman 20th September 2002 SM64 V2 1 200902 5 1 Cross cutting To cut wood at right angles to the grain...