INSTRUCTIONS FOR:
MOBILE PARTS CLEANING TANK
MODEL:
SM26
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained,
give you years of trouble free performance.
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE
AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1.1.
ELECTRICAL SAFETY.
WARNING! It is the user’s
responsibility to read, understand and comply with the following:
You must check all electrical equipment and appliances to ensure they
are safe before using. You must inspect power supply leads, plugs
and all electrical connections for wear and damage. You must ensure
the risk of electric shock is minimised by the installation of appropriate
safety devices. An RCCB (Residual Current Circuit Breaker) should be
incorporated in the main distribution board. We also recommend that
an RCD(Residual Current Device) is used with all electrical products.
It is particularly important to use an RCD with portable products that
are plugged into an electrical supply not protected by an RCCB. If in
doubt consult a qualified electrician. You may obtain a Residual
Current Device by contacting your Sealey dealer. You must also read
and understand the following instructions concerning electrical safety.
1.1.1.
The Electricity At Work Act 1989
requires all portable electrical
appliances, if used on business premises, to be tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2. The
Health & Safety at Work Act 1974
makes owners of electrical
appliances responsible for the safe condition of the appliance and the
safety of the appliance operator.
If in any doubt about electrical
safety, contact a qualified electrician.
1.1.3. Ensure the insulation on all cables and the product itself is safe before
connecting to the mains power supply. See 1.1.1. & 1.1.2. above and
use a Portable Appliance Tester (PAT).
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5. Regularly inspect power supply, leads, plugs for wear and damage
and all electrical connections to ensure that none is loose.
1.1.6.
Important:
Ensure the voltage marked on the product is the same as
the electrical power supply to be used, and check that plugs are fitted
with the correct capacity fuse. A 13 amp plug may require a fuse
smaller than 13 amps for certain products, see fuse rating below.
1.1.7. DO NOT pull or carry the appliance by its power supply lead.
1.1.8. DO NOT pull power plug from socket by the power cable.
1.1.9. DO NOT use worn or damaged leads, plugs or connections.
Immediately replace or have repaired by a qualified electrician. A U.K.
3 pin plug with ASTA/BS approval is fitted. In case of damage, cut off
and fit a new plug according to the following instructions (discard old
plug safely). (UK only - see diagram below).
Ensure the unit is
correctly earthed via a three-pin plug.
a) Connect the green/yellow earth wire to the earth terminal ‘E’.
b) Connect the brown live wire to live terminal ‘L’.
c) Connect the blue neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires
have been correctly connected, that the cable outer insulation
extends beyond the cable restraint and that the restraint is tight.
Double insulated products are fitted with live (BROWN) and neutral
(BLUE) wires only. Double insulated products are always marked with
this symbol .
To re-wire, connect the brown and blue wires as
indicated below. DO NOT connect the brown or blue to the earth
terminal.
1.1.10. Some products require
more than a 13 amp
electrical supply. In such
a case, NO plug will be
fitted.
You must
contact
a qualified electrician to
ensure a 30 amp fused
supply is available. We
recommend you discuss
the installation of an
industrial round pin plug
and socket with your
electrician.
1.1.11.
Cable extension reels.
When a cable extension
reel is used it should
be fully unwound before
connection. A cable reel with an RCD fitted is recommended since any
product which is plugged into the cable reel will be protected. The
section of the cores of the cable is important and should be at least
1.5mm², but to be absolutely sure that the capacity of the cable reel
is suitable for this product and for others that may be used in the other
output sockets, we recommend the use of 2.5mm² section cable.
1. SAFETY INSTRUCTIONS
1.2
GENERAL SAFETY
WARNING! Ensure Health & Safety, local authority, and general work
shop practice regulations are adhered to when using this equipment.
Familiarise yourself with the applications, limitations and potential
hazards of the tank.
WARNING! Disconnect the tank from the mains power before
changing accessories, servicing or performing any maintenance.
Replace or repair damaged parts. Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate the warranty.
WARNING! DO NOT modify the lid or jam it open. Keep the lid and
holding screws in place, tight and in good working order.
Locate tank in a suitable work area and keep area clean and tidy and
free from unrelated materials. Ensure there is adequate lighting.
Ensure there are no flammable or combustible materials near the
work area.
In case of fire in tank, do not attempt to move unit or remove parts
from tank. The lid is fusible and will automatically close extinguishing fire.
When cleaning parts ensure that nothing in the tank, including any
parts basket, is in a position that would prevent the lid from closing
fully if and when the fusible link activates.
WARNING! DO NOT SMOKE and keep sources of ignition, such as
heaters, lamps, etc., away from the unit, together with flammable or
combustible materials, as there is an explosion risk.
Use only water soluble solvent. We recommend Sealey AK25 or AK2501.
WARNING! When operating the tank always wear approved eye or
face protection and appropriate protective clothing, including gloves,
to prevent the cleaning agent contacting the skin.
Maintain correct balance and footing. Ensure the floor is not slippery
and wear non-slip shoes.
Remove ill fitting clothing. Remove ties, watches, rings,and other
loose jewellery and contain and/or tie back long hair.
Keep children and unauthorised persons away from the work area.
Avoid unintentional starting.
Keep the tank clean for best and safest performance.
Dispose of waste liquids in accordance with local authority regulations.
When not in use switch off the tank, close the lid and remove the plug
from the power supply.
DO NOT overfill tank or allow fluid level to fall below pump inlet.
DO NOT use the tank for a task it is not designed to perform.
DO NOT operate the tank if any parts are damaged or missing as this
may cause failure and/or personal injury.
DO NOT allow untrained persons to operate the tank.
DO NOT operate the tank when you are tired or under the influence
of alcohol, drugs or intoxicating medication.
DO NOT leave the tank operating unattended.
WARNING! Protect the environment - DO NOT allow uncontrolled
discharge of pollutants including degreasing solvent.
SM26
ISSUE NO:1 16/09/08
2. INTRODUCTION & SPECIFICATION
Heavy-duty three tier parts washer with one-piece tank, draining board and
bucket. Fully sealed electric motor with magnetic drive pump unit. Lid features
self-latching fusible link which automatically snaps lid shut in the event of a fire.
Includes removable shelf inside tank. Flexible metal nozzle directs solvent over
work. Fitted with Ø100mm castor wheels for easy manoeuvrability.
Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SM26
Overall Height: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1325mm
Overall Length: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 970mm
Tank Height: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200mm
Tank Width:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 482mm
Tank Length:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 711mm
Pump Output/hr: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160ltr
Motor Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11W
Supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V - 3A
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36kg
Maximum Working Capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60ltr
Minimum Working Capacity:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22ltr
FUSE RATING
THIS PRODUCT MUST BE FITTED WITH A
3 AMP FUSE
Yellow & Green
Earth Wire
Cable
Restraint
Brown
Live
Wire
Blue
Neutral
Wire