background image

INSTRUCTIONS FOR:

MOBILE PARTS CLEANING TANK

MODEL: 

SM26

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, 
give you years of trouble free performance.

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS. 

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE 
AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1.1. 

ELECTRICAL SAFETY. 

 WARNING! It is the user’s 

 

responsibility to read, understand and comply with the following:

 

You must check all electrical equipment and appliances to ensure they  

 

are safe before using. You must inspect power supply leads, plugs  

 

and all electrical connections for wear and damage. You must ensure  

 

the risk of electric shock is minimised by the installation of appropriate  

 

safety devices. An RCCB (Residual Current Circuit Breaker) should be  

 

incorporated in the main distribution board. We also recommend that  

 

an RCD(Residual Current Device) is used with all electrical products.  

 

It is particularly important to use an RCD with portable products that  

 

are plugged into an electrical supply not protected by an RCCB. If in  

 

doubt consult a qualified electrician. You may obtain a Residual  

 

Current Device by contacting your Sealey dealer. You must also read  

 

and understand the following instructions concerning electrical safety.

1.1.1. 

The Electricity At Work Act 1989

 requires all portable electrical 

 

appliances, if used on business premises, to be tested by a qualified  

 

electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2.  The 

Health & Safety at Work Act 1974

 makes owners of electrical  

 

appliances responsible for the safe condition of the appliance and the  

 

safety of the appliance operator. 

If in any doubt about electrical 

 

safety, contact a qualified electrician.

1.1.3.  Ensure the insulation on all cables and the product itself is safe before  
 

connecting to the mains power supply. See 1.1.1. & 1.1.2. above and  

 

use a Portable Appliance Tester (PAT).

1.1.4.  Ensure that cables are always protected against short circuit and overload.
1.1.5.  Regularly inspect power supply, leads, plugs for wear and damage  
 

and all electrical connections to ensure that none is loose. 

1.1.6. 

Important:

 Ensure the voltage marked on the product is the same as  

 

the electrical power supply to be used, and check that plugs are fitted  

 

with the correct capacity fuse. A 13 amp plug may require a fuse 

 

smaller than 13 amps for certain products, see fuse rating below. 

1.1.7.  DO NOT pull or carry the appliance by its power supply lead. 
1.1.8.  DO NOT pull power plug from socket by the power cable.
1.1.9.  DO NOT use worn or damaged leads, plugs or connections.   
 

Immediately replace or have repaired by a qualified electrician. A U.K.  

 

3 pin plug with ASTA/BS approval is fitted. In case of damage, cut off 

 

and fit a new plug according to the following instructions (discard old  

 

plug safely). (UK only - see diagram below).

 Ensure the unit is 

 

correctly earthed via a three-pin plug. 

 

a)  Connect the green/yellow earth wire to the earth terminal ‘E’.

 

b)  Connect the brown live wire to live terminal ‘L’.

 

c)  Connect the blue neutral wire to the neutral terminal ‘N’.

 

d)  After wiring, check that there are no bare wires, that all wires  

 

have been correctly connected, that the cable outer insulation  

 

extends beyond the cable restraint and that the restraint is tight.

 

Double insulated products are fitted with live (BROWN) and neutral  

 

(BLUE) wires only. Double insulated products are always marked with

 

this symbol      . 

To re-wire, connect the brown and blue wires as  

 

indicated below. DO NOT connect the brown or blue to the earth  

 

terminal.

1.1.10.  Some products require  
 

more than a 13 amp 

 

electrical supply. In such  

 

a case, NO plug will be 

 

fitted. 

You must

 contact  

 

a qualified electrician to  

 

ensure a 30 amp fused   

 

supply is available. We  

 

recommend you discuss  

 

the installation of an 

 

industrial round pin plug  

 

and socket with your 

 

electrician. 

1.1.11. 

Cable extension reels.

  

 

When a cable extension  

 

reel is used it should  

 

be  fully unwound before  

 

connection. A cable reel with an RCD fitted is recommended since any  

 

product which is plugged into the cable reel will be protected. The 

 

section of the cores of the cable is important and should be at least  

 

1.5mm², but to be absolutely sure that the capacity of the cable reel  

 

is suitable for this product  and for others that may be used in the other  

 

output sockets, we recommend the use of 2.5mm² section cable.

1.  SAFETY INSTRUCTIONS

1.2 

GENERAL SAFETY

 

WARNING! Ensure Health & Safety, local authority, and general work 

 

shop practice regulations are adhered to when using this equipment.

 

Familiarise yourself with the applications, limitations and potential  

 

hazards of the tank.

 

WARNING! Disconnect the tank from the mains power before 

 

changing accessories, servicing or performing any maintenance.

 

Replace or repair damaged parts. Use genuine parts only.   

 

Unauthorised parts may be dangerous and will invalidate the warranty.

 

WARNING! DO NOT modify the lid or jam it open. Keep the lid and  

 

holding screws in place, tight and in good working order. 

 

Locate tank in a suitable work area and keep area clean and tidy and  

 

free from unrelated materials. Ensure there is adequate lighting.

 

Ensure there are no flammable or combustible materials near the  

 

work area.

 

In case of fire in tank, do not attempt to move unit or remove parts  

 

from tank. The lid is fusible and will automatically close extinguishing fire.

 

When cleaning parts ensure that nothing in the tank, including any  

 

parts basket, is in a position that would prevent the lid from closing  

 

fully if and when the fusible link activates.

 

WARNING! DO NOT SMOKE and keep sources of ignition, such as  

 

heaters, lamps, etc., away from the unit, together with flammable or  

 

combustible materials, as there is an explosion risk.

 

Use only water soluble solvent. We recommend Sealey AK25 or AK2501.

 

WARNING! When operating the tank always wear approved eye or  

 

face protection and appropriate protective clothing, including gloves,  

 

to prevent the cleaning agent contacting the skin.

 

Maintain correct balance and footing. Ensure the floor is not slippery  

 

and wear non-slip shoes.

 

Remove ill fitting clothing. Remove ties, watches, rings,and other  

 

loose jewellery and contain and/or tie back long hair.

 

Keep children and unauthorised persons away from the work area.

 

Avoid unintentional starting.

 

Keep the tank clean for best and safest performance. 

 

Dispose of waste liquids in accordance with local authority regulations.

 

When not in use switch off the tank, close the lid and remove the plug  

 

from the power supply. 

 

DO NOT overfill tank or allow fluid level to fall below pump inlet.

 

DO NOT use the tank for a task it is not designed to perform.

 

DO NOT operate the tank if any parts are damaged or missing as this  

 

may cause failure and/or personal injury.

 

DO NOT allow untrained persons to operate the tank.

 

DO NOT operate the tank when you are tired or under the influence  

 

of alcohol, drugs or intoxicating medication.

 

DO NOT leave the tank operating unattended.

 

WARNING! Protect the environment - DO NOT allow uncontrolled 

 

discharge of pollutants including degreasing solvent.

SM26

ISSUE NO:1 16/09/08

 

2.     INTRODUCTION & SPECIFICATION

Heavy-duty three tier parts washer with one-piece tank, draining board and 
bucket. Fully sealed electric motor with magnetic drive pump unit. Lid features 

self-latching fusible link which automatically snaps lid shut in the event of a fire. 

Includes removable shelf inside tank. Flexible metal nozzle directs solvent over 
work. Fitted with Ø100mm castor wheels for easy manoeuvrability.

Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SM26 
Overall Height:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1325mm 
Overall Length: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 970mm 
Tank Height: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200mm 
Tank Width:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 482mm 
Tank Length:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 711mm 
Pump Output/hr: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160ltr 
Motor Power:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11W 
Supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  230V - 3A 
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36kg 
Maximum Working Capacity:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60ltr 
Minimum Working Capacity:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22ltr 

FUSE RATING

THIS PRODUCT MUST BE FITTED WITH A 

3 AMP FUSE

Yellow & Green 
Earth Wire 

Cable 
Restraint

Brown
Live 
Wire

Blue 
Neutral 
Wire

Reviews: