background image

9L ManuaL VacuuM OiL & FLuid 

ExtractOr

Model no: 

S01167

thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SaFEty  

 

‰

  WarninG!

 ensure Health & Safety, local authority, and general workshop practice regulations are strictly adhered to when using this    

 equipment.

 

‰

  

WarninG! 

ensure that you wear protective clothing, gloves, goggles, face mask as appropriate for the fluid being extracted.

 

9

   Keep the extractor clean and maintain it in good condition (use an authorised service agent).

 

9

   Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

 

9

   Check extractor connections and fittings before use. When the extractor is being used, check that there are no leaks.

 

9

   ensure that the extractor’s tank capacity exceeds the amount of fluid to be collected.

 

9

   Avoid unintentional starting of the extractor and ensure that the end of the suction tube is fully submerged in the fluid before operating.

 

9

   Keep the work area clean, uncluttered and ensure there is adequate lighting.

 

9

  Maintain correct balance and footing. ensure the floor is not slippery and wear non-slip shoes.

 

9

   Keep children and unauthorised persons away from the working area.

 

9

   dispose of waste fluids in accordance with local authority regulations.

 

9

   Use only to extract engine or transmission oils, or similar non-corrosive fluids. Unit may also be used for the transfer of water. 

 

‰

   WarninG! dO nOt

 allow uncontrolled discharge of fluids thus polluting the environment.

 

8

  dO nOt 

pull or yank any pipes or hoses and do not attempt to move the extractor by pulling the hose.

 

8

  dO nOt

 leave the extractor operating unattended.

 

8

  dO nOt 

use to extract hazardous or harmful chemicals, solvents, petrol, diesel, kerosene, alkaline or acids. If by chance such fluids  

  are used in the unit, it must be immediately drained and thoroughly cleaned. Use with prohibited fluids will invalidate your warranty.

 

8

  dO nOt

 store fluids in the extractor’s tank. After extracting fluid, it must be emptied into an approved receptacle as soon as possible.

 

8

  dO nOt

 dismantle, tamper or adapt the extractor for any purpose other than for which it is designed.

 

8

  dO nOt

 store in areas of high temperature, direct sunlight, rain or snow.

 

8

 

dO nOt

 leave the unit in a pressurised state. 

 

‰

  

WarninG!

 When the extractor’s tank contains liquid that is under pressure 

dO nOt

 remove or insert the extension tube connector into  

  the inlet/outlet fitting as this may result in a sudden discharge of liquid that could be dangerous.

 

9

  Always press the pressure relief button before connecting or disconnecting the extension tube or inlet coupling.

2.  intrOductiOn

 

9l Capacity device constructed from composite materials. Uses manual pump to generate vacuum. Suitable for the extraction of all  

 

types of engine, transmission and lubricating oil from cars, motorcycles, marine engines, stationary engines and industrial machinery.  

 

Also suitable for low viscosity fluids such as water. Supplied with Ø4, Ø6, Ø8 and Ø10mm suction probes, and Ø4 x 600mm  

 

 

brass extension tube. Uses probes to extract engine oil through the dipstick tube.

3.  SpEciFicatiOn

Model no: ..................................................................S01167

Capacity: ........................................................................... 9 l 

Suction probes: 

 Ø4 x 1000, Ø6 x 1000, Ø8 x 1000, Ø10 x 1000mm 

extension tube: ........................................

Brass Ø4 x 600mm

4.  OpEratiOn

4.1. 

  

SEt up FOr OiL cHanGE 

 nOtE:

 Ensure you read, understand and apply the Section 1 Safety Instructions and 

 

consult manufacturer’s workshop manual for any specific procedures. 

4.1.1. 

  

ensure that the vehicle is level. Run the engine for approximately five minutes to ensure 

 

that the oil is warm. Switch off engine.

4.1.2. 

  

Remove the oil dipstick from the engine.

4.1.3. 

  

Insert the appropriate extracting probe into the dipstick

 

tube making sure it reaches the bottom of the sump. 

4.1.4. 

  

Connect the extracting probe to the extension tube using its 

 

black plastic adaptor. The tubes are a push fit into  the adaptor.

S

01167   Issue 1  25/10/19

Original Language Version

© Jack Sealey limited

Refer to 

instructions

Wear eye 

protection

 Wear protective 

gloves

Reviews: