1. SAFETY INSTRUCTIONS

IMPORTANT

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS. USE

THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE

DAMAGE OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY. RETAIN THESE INSTRUCTIONS FOR FUTURE USE.

1.2

GENERAL SAFETY

3

Disconnect the drill from the mains power before changing accessories, servicing or performing any maintenance.

3

Maintain the drill in good condition. Check moving parts alignment, and keep drill bits sharp. If necessary use an authorised service agent.

3

Replace or repair damaged parts. 

Use genuine parts only. Non authorised parts may be dangerous and will invalidate the warranty.

3

Keep the drill clean for best and safest performance. Keep the ventilation slots clear.

3

Wear approved safety eye and ear protection and if dust is generated a dust mask. Rubber gloves are recommended when using out doors,

and safety gloves when drilling items such as steel, brick work etc. Ensure you only hold the drill by the plastic handles.

3

Remove ill fitting clothing. Remove ties, watches, rings, and other loose jewellery, and contain long hair.

3

Use drill in an adequate working area for its function, keep area clean and tidy and free from unrelated materials. Ensure good lighting.

3

Prevent body contact with grounded surfaces to avoid electric shock i.e. pipes, radiators, range, refrigerators etc.

3

Evaluate your working area before using the drill i.e. ceiling, floors and enclosures may contain hidden electrical items or water piping. 

3

Prolonged exposure to vibration from the drill poses a health risk. It is the operator’s responsibility to correctly assess the potential hazard and

follow/issue guidelines for safe periods of use and use/offer suitable protective equipment.

3

The side handle should always be attached for use. When the standard chuck is used, ensure the key is removed before starting the drill.

3

Maintain correct balance and footing. Ensure the floor is not slippery and wear non slip shoes.

3

Keep children and non essential persons away from the working area.

3

Use correctly rated drill and chisel bits, with the the correct connection type.

3

Secure non stable work piece with a clamp, vice or other adequate holding device. 

7

DO NOT force drill to achieve a task its not designed for.

7

DO NOT operate drill where there are flammable liquids or gases.

7

DO NOT use drill if parts are damaged or missing as this may cause failure and/or personal injury.

7

DO NOT get the drill wet or use in damp or wet locations. 

7

DO NOT hold unsecured work in your hand and avoid unintentional starting.

7

DO NOT leave the drill running whilst unattended.

7

DO NOT carry the drill with your finger on the power switch. 

7

DO NOT use drill when you are tired, under the influence of alcohol, drugs or intoxicating medication.

3

When not in use switch drill off, remove power plug, clean and store in carry case and place a in safe, dry, child proof location.

SDS620 - 0064 - (1) - 150600

1.1.

ELECTRICAL SAFETY. 

p

p

 

 

WARNING! It is the user’s responsibility to read, understand and comply with the following:

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and all

electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety

devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD

(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD together with portable products that are

plugged into an electrical supply not protected by an RCCB. If in doubt consult a professional electrician. You may obtain a Residual Current

Device by contacting your Sealey dealer. 

You must

also read and understand the following instructions concerning electrical safety.

1.1.1. The 

Electricity At Work Act 1989

requires all portable electrical appliances, if used on business premises, to be tested by 

a qualified  Electrician at least once a year by using a Portable Appliance Tester (PAT).

1.1.2. The 

Health & Safety at Work Act 1974

makes owners of electrical appliances responsible for the safe condition of the appliance, 

and the safety of the appliance operator. 

If in doubt about electrical safety, contact a qualified electrician.

1.1.3. Ensure the insulation on all cables and the product itself is safe before connecting to the mains power 

supply. See 1.1.1. & 1.1.2. above and use a Portable Appliance Tester (PAT).

1.1.4. Ensure that cables are always protected against short circuit and overload.

1.1.5. Regularly inspect power supply, leads, plugs and all electrical connections for wear and damage, 

especially power connections, to ensure that none are loose. 

1.1.6.

Important:

Ensure the voltage marked on the product is the same as the electrical power supply

to be used, and check that plugs are fitted with the correct capacity fuse. A 13Amp plug may require 

a fuse smaller than 13Amps for certain products (

subject to 1.1.10. below)

see fuse rating at right. 

1.1.7. DO NOT pull or carry the powered appliance by its power supply lead. 

1.1.8. DO NOT pull power plugs from sockets by the power cable.

1.1.9. DO NOT use worn or damage leads, plugs or connections. Immediately replace or have repaired by 

a qualified Electrician. A U.K. 3 pin plug with ASTA/BS approval is fitted. In case of damage, cut off 

and fit a new plug according to the following instructions (discard old plug safely).

(UK only - see diagram at right). 

Ensure the unit is correctly earthed via a three-pin plug. 

a)  Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

b) Connect the BROWN live wire to live terminal ‘L’.

c)  Connect the BLUE neutral wire to the neutral terminal ‘N’.

After wiring, check there are no bare wires, that all wires have been correctly connected and that the wire restraint is tight.

Double insulated products are often fitted with live (BROWN) and neutral (BLUE) wires only. Double insulated products are always marked with

this symbol      .

To re-wire, connect the brown & blue wires as indicated above. DO NOT 

connect the brown or blue to the earth terminal.

1.1.10.

Cable extension reels

. When a cable extension reel is used it should be fully unwound before connection. A cable reel with an RCD

fitted is recommended since any product which is plugged into the cable reel will be protected. The section of the cable on the cable

reel is important. We recommend that at least 1.5mm

2

section cable but to be absolutely sure that the capacity of the cable reel is 

suitable for this product and for others that may be used in the other output sockets, we recommend the use of 2.5mm

2

section cable.

Blue

Neutral 

wire

Yellow & Green 

Earth wire 

wire 

restraint

FUSE RATING

THIS PRODUCT MUST BE FITTED 

WITH A: 

5 Amp FUSE

Brown

Live 

wire