background image

9,000BTU/HR AIR CONDITIONER/DEHUMIDIFIER

MODEL NO: 

SAC9002

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY  

1.1. 

  

ELECTRICAL SAFETY

 

‰

  

WARNING!

 It is the user’s responsibility to check the following:

 

Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all  

 

electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical  

 

products. You may obtain an RCD by contacting your local Sealey stockist. 

 

If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable  

 

 

Appliance Test) tested.

 

Electrical safety information: 

 it is important that the following information is read and understood.

1.1.1.   

Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.1.2.   

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.1.3. 

  

IMPORTANT

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the  

 

correct fuse - see fuse rating in these instructions.

 

8

   DO  NOT

 pull or carry the appliance by the power cable.

 

8

  

DO NOT

 pull the plug from the socket by the cable. 

 

8

   DO  NOT

 use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or 

             replaced immediately by a qualified electrician.

1.1.4. 

  

This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

      

If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

      

Ensure that repairs are carried out by a qualified electrician.

         

Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

 

A) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

B) Connect the BROWN live wire to the live terminal ‘L’.

 

C) Connect the BLUE neutral wire to the neutral terminal ‘N

’.

      

Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

        

Sealey recommend that repairs are carried out by a qualified electrician.

1.1.5. 

  

Products which require more than 13 amps are supplied without a plug. Contact a qualified electrician to ensure that a suitably rated  

 

supply is available. Ensure that an industrial round pin plug and socket are fitted by a qualified electrician. 

1.1.6.   

If an extension cable reel is used, ensure that it is fully unwound before connection. Use a reel that includes an RCD, an appliance  

 

will be protected by the RCD. The cable core section is important and should be at least 1.5mm

2

. Ensure that the cable of the reel is 

 

appropriate for this product. We recommend the use of 2.5mm² core section cable.

1.2.    

GENERAL  SAFETY

 

9

  

Check that the unit is in sound condition and good working order. Take immediate action to repair or replace damaged parts.

 

  Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

 

 NOTE: 

Appliance is filled with propane gas R290.

 

 NOTE:

 Only install, operate or store in a room with a floor area greater than 12.92m

2

.

 

8

  DO NOT 

attempt any repairs / maintenance unless suitably qualified. 

 

8

  DO NOT

 stand or place any object closer than 500mm from the unit. 

 

 

 

 

 

 

 

8

   DO  NOT

 obstruct the air intakes or outlets of the unit, and 

DO NOT

 cover with washed clothes.

 

8

   DO  NOT 

place any object into the outlets - the unit has a fan running at high speed, contact with this will cause injury.

 

8

   DO  NOT

 operate the unit when you are tired or under the influence of alcohol, drugs or intoxicating medication.

 

8

   DO  NOT 

switch the unit off by disconnecting it from the mains. 

ALWAYS 

switch it off using the Power button.

 

8

   DO  NOT 

remove the float lever from the water collection tank.

 

8

   DO  NOT 

connect or disconnect the plug from the mains with wet hands.

 

8

   DO  NOT

 use the unit outside.

 

8

  

DO NOT

 install or operate this air conditioner in a bathroom or other wet environments.

 

9

   To prevent water from freezing, 

DO NOT

 use the unit at ambient temperatures below 0°C. 

 

 

9

   Always discard the water from the collection tank, 

DO NOT

 use it for any other purpose.

 

9

   Place the unit on a level and stable surface.

 

9

   Ensure that heating appliances are not exposed to the flow of air from the unit.

Replacement fuse 

rating:

13A

S

AC9002         Issue 1         19/03/20

Original Language Version

© Jack Sealey Limited

Refer to 

instructions

Do not cover

Indoor use only

Caution:

Risk of fire

Summary of Contents for SAC9002

Page 1: ...BROWN live wire to the live terminal L C Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 1 5 Products which require more than 13 amps are supplied without a plug Contact a qualified electrician to ensure that a suit...

Page 2: ... 5m Max water extraction rate 24L day Noise level 65db A Power 1010W Rated capacity 2640W Refrigerant R290 Suction side pressure 1 3Mpa Supply 230V 50Hz 4 CONTENTS SEE FIG 1 5 INSTALLATION WARNING leave this mobile air conditioner in an upright position for at least 2 hours before first use Ensure that the air conditioner remains in an upright position whilst it is being moved Place the air condit...

Page 3: ...w by pressing the Fan button on the display The relevant LED will show the setting 6 3 3 The cooling temperature can be set using the up and down arrows and will be shown in the LED display window 6 3 4 Temperatures can be displayed in either Centigrade or Fahrenheit by pressing both up and down arrows simultaneously 6 4 DEHUMIDIFYING MODE 6 4 1 To engage the dehumidifying function press the Mode ...

Page 4: ...to drain the condensate in the unit otherwise the unit will shut down automatically after the buzzer gives off 5 beeps If the unit is not shut down manually the unit will be restored to the previous operating status automatically once the water is fully drained Or the power may be turned on again to start the unit 6 9 3 DELAY PROTECTION FUNCTION OF THE COMPRESSOR This unit offers restart protectio...

Page 5: ...the unit DO NOT soak the cleaning cloth 8 MOVING THE UNIT 8 1 To move the unit hold the top of the air outlet on the front of the unit with one hand and the handle position at the top of the back of the unit with another hand Ensure that the unit remains upright DO NOT hold the horizontal louvre by hand 8 2 Leave the unit in the upright position when handling or moving it 8 3 To handle or move the...

Page 6: ...n Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information BATTERY REMOVAL REMOVE BATTERY FROM REMOTE Under the Waste Batteries and Accumulators Regulations 2009 Jack Sealey Ltd are required to inform potential purchasers of products containing...