background image

AIR NEEDLE SCALER - PISTOL TYPE

MODEL NO: 

SA501

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 
instructions, and properly maintained, give you years of trouble free performance.

I

MP

PO

R

RTA

TANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

TH

HE

P

PR

O

ODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR

PE

ER

S

SON

NAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1. SAFETY

   Familiarise yourself with the applications, limitations and hazards of the air needle scaler.

WARNING!

 Ensure health & safety, local authority, and general workshop practice regulations are adhered to when using                  

 this 

equipment.

WARNING!

 Disconnect the air needle scaler from the air supply before changing accessories or servicing.

  Maintain 

the 

air needle scaler in good condition and replace any damaged or worn parts. Use genuine parts only. Unauthorised parts  

  may be dangerous and will invalidate the warranty.

WARNING!

 Check correct air pressure is maintained and not exceeded. Recommend pressure is 90psi.

   Keep the air hose away from heat, oil and sharp edges. Check the air hose for wear before each use and ensure that all connections  
  are tight and secure.

Only use needles which are speci

fi

 cally designed for use with an air needle scaler.

WARNING!

 Always wear approved safety eye/face shield, ear defenders, and hand protection when operating the air needle scaler.  

  A full range of personal safety equipment is available from your Sealey stockist.

Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.

   Keep children and non-essential persons away from the working area.

DO NOT

 use the air needle scaler for a task it is not designed to perform.

DO NOT

 use the air needle scaler if damaged or thought to be faulty. (Contact Sealey service agent).

DO NOT

 use the air needle scaler unless you have been instructed in its use by a qualified person.

DO NOT

 carry the air needle scaler by the air hose, or yank the hose from the air supply.

DO NOT

 operate the air needle scaler if you are tired or under the influence of alcohol, drugs or intoxicating medication.

DO NOT

 carry the air needle scaler with your hand on the power trigger in order to avoid unintentional starting.

DO NOT

 direct the air from the air hose at yourself or others.

   When not in use disconnect the air needle scaler from air supply and store in a safe, dry, childproof location.

DO NOT

 operate the air needle scaler near flammable substances or flammable containers.

   Dress properly. Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery and contain long hair.

WARNING!

 Secure workpiece with clamps or a vice where practical.

DO NOT

 hold an unsecured workpiece in your hand.

WARNING! The warnings, cautions and instructions discussed in this instruction manual cannot cover all possible  

 

  conditions and situations that may occur. It must be understood that common sense and caution are factors which  

 

  cannot be built into this product, but must be applied by the operator.

2. INTRODUCTION

Pistol type scaler suitable for cleaning heavy paint and rust scale from metal surfaces. Removable needle head allows use as a standard air 
hammer but requires additional chisel set and spring retainer (not included). Features variable speed trigger control. Spring retainer, needle 
and chisel sets available separately.

3. SPECIFICATION

Model No: ................................................................... SA501
Air Consumption: ........................................................... 4cfm
Consumable Parts:
Replacement Needle Set (19pc) .............................. SA50.02
Optional Spring Retainer: ....................................... SA11R/17
Optional Chisel Sets: ........................AK50 (5pc), AK57 (7pc)
Inlet Size: ..................................................................1/4”BSP
Noise Power:........................................................... 111dB(A)
Noise Pressure: ...................................................... 100dB(A)
No-Load Speed: ...................................................... 4500bpm
Operating Pressure: ...................................................... 90psi
Stroke: ......................................................................... 43mm
Vibration: ..................................................................... 13m/s²
Uncertainty: ................................................................ 5.2m/s²

SA501  Issue 1 28/01/22

Original Language Version

© Jack Sealey Limited

Refer to 

instructions

   

fi

 g.1

Wear eye 

protection

Wear protective 

gloves

Wear ear 

protection

Wear a mask

Reviews: