3.1. 

Air Supply

  

WARNING! 

Ensure the air supply is clean and does not exceed 90psi while operating the riveter. Too high an air  

 

 

pressure and unclean air will cause excessive wear, and may be dangerous, causing damage and/or personal injury. 

 

Recommended hook-up procedure is shown in Fig.1.

3.1.1.  Ensure the riveter air valve (or trigger) is not depressed before connecting to the air supply.

3.1.2.  You will require an air pressure between 70-90psi, and an air flow according to the specification above.

3.1.3.  Drain the air tank daily. Water in the air line will damage the riveter and invalidate your warranty.

 

3.1.4.  Clean air inlet filter weekly. 

3.1.5.  Line pressure should be increased to compensate for unusually long air hoses (over 8 metres). The minimum hose diameter should   

 

be 1/4” I.D. and fittings must have the same inside dimensions. 

3.1.6.  Keep hose away from heat, oil and sharp edges. Check hoses for wear, and make certain that all connections are secure. 

3.2.      Couplings 

 

Vibration may cause failure if a quick change coupling is connected directly to the riveter. To overcome this, connect a leader hose   

 

Sealey model number AH2R or AH2R/38 - to the riveter. A quick change coupling may then be used to connect the leader hose to the  

 

air line recoil hose. See Fig.1 & 2.

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

1.  SAFETY INSTRUCTIONS

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. 

USE  THE  PRODUCT  CORRECTLY  AND  WITH  CARE  FOR  THE  PURPOSE  FOR  WHICH  IT  IS  INTENDED.  FAILURE  TO  DO  SO  MAY  CAUSE 

DAMAGE AND/OR  PERSONAL  INJURY, AND  WILL  INVALIDATE  THE  WARRANTY.  PLEASE  KEEP  INSTRUCTIONS  SAFE  FOR  FUTURE  USE.

InSTRuCTIonS FoR:

AIR/HYDRAULIC RIVETER HEAVY-DUTY 

VACUUM SYSTEM

MoDEL no:

 

SA316.V2

Powerful, extra heavy-duty tool suitable for aluminium, steel, stainless steel rivets and structural rivets from 3/16” to 1/4”. Trigger operated 

riveter with hardened steel jaw assembly and air-actuated vacuum rivet shaft collector. Resilient grip for added comfort and hanging loop for 

use with balancer. Supplied with three riveting nozzles, two spanners and oil can.

Nozzle Sizes:

 . . . . . . . . .3/16”(4.8mm), 7/32”(5.6mm)

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4”(6.4mm)

Air Consumption:

. . . . . . . . . . . . . . . . . . . . . . 4.0cfm

Operating Pressure:

. . . . . . . . . . . . . . . . . . . . . 90psi

Air Inlet Size:

 . . . . . . . . . . . . . . . . . . . . . . . . 1/4”BSP

Weight:

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.9kg

3.  AIR SUPPLY

2.  INTRODUCTION & SPECIFICATIONS

 

WARNING!

 

Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.

  Familiarise yourself with this product’s application and limitations, as well as the potential hazards peculiar to the riveter.

 

WARNING!

 

Disconnect the riveter from the air supply before changing accessories, servicing or performing any maintenance.

  Maintain the

 

riveter in good condition (use an authorised service agent).

  Replace or repair damaged parts. 

Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

  use in a suitable work area. Keep area free from unrelated materials and ensure that there is adequate lighting.

  Keep the riveter clean for best and safest performance.

 

WARNING! 

Always wear approved eye (or face) and hand protection when operating the riveter.  

  Maintain correct balance and footing. Do not over reach, ensure the floor is not slippery, wear non-slip shoes.

  Remove ill fitting clothing. Remove ties, watches, rings, loose  

 

  jewellery. Contain or tie back long hair.

 

Wear appropriate protective clothing and keep hands and body clear  

  of working parts.

  Keep the riveter away from your body and at a safe distance from    

  others.

  Keep children and unauthorised persons away from the working area.

  Secure non stable workpiece with a clamp, vice or other adequate holding device. 

  Ensure that spent rivet stems are disposed of correctly and do not cause a hazard.

 

WARNING!

 Ensure correct air pressure is maintained and not exceeded.  

 

  Recommended pressure 85-90psi.

  Keep air hose away from heat, oil and sharp edges. Check air hose for wear   

  before each use, and ensure that all connections are secure.

 

Avoid unintentional starting.

 

DO NOT

 use the riveter for a task it is not designed to perform.

 

DO NOT

 operate the riveter if any parts are damaged or missing as this may   

  cause failure and/or personal injury.

 

DO NOT

 carry by the hose, or yank the hose from the air supply.

 

DO NOT

 get the riveter wet or use in damp or wet locations or areas where    

  there is condensation.

 

DO NOT

 allow untrained persons to operate the riveter.

 

DO NOT

 operate the riveter when you are tired or under the influence of  

 

  alcohol, drugs or intoxicating medication.

 

DO NOT

 direct air from the air hose at yourself or others.

  When not in use, disconnect from the air supply and store in a safe, dry,

  childproof location.

Original Language Version

SA316.V2    Issue: 1 - 28/10/10